Search results for "Artery"
showing 10 items of 2026 documents
A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm
2013
We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation. © Turkish Society of Radiology 2012.
Effects of Steatosis on Hepatic Hemodynamics in Patients with Metabolic Syndrome
2015
The aim of our study was to assess the hemodynamic changes in hepatic and splenic circulation using B-mode ultrasonography and color Doppler ultrasonography, in a population of patients with metabolic syndrome divided with respect to the presence or absence of steatosis diagnosed by ultrasonography. One hundred forty-one patients were included in the study. The severity of non-alcoholic fatty liver disease was classified as mild, moderate or severe. Visceral fat thickness, longitudinal diameter of the spleen, diameter of the portal vein, mean maximum portal vein flow velocity, hepatic artery and splenic artery resistivity indexes and hepatic vein flow phasicity were measured. Non-alcoholic …
Endovascular treatment options for complex abdominal aortic aneurysms
2015
Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …
Role of cardiac computed tomography in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic…
2016
OBJECTIVE The aim of our study was to evaluate the diagnostic performance of cardiac computed tomography (CCT) in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography. METHODS We conducted a retrospective analysis of patients with an aneurysm 45 mm or greater at transthoracic echocardiography who underwent CCT from 2012 to 2014 in our hospital. We calculated the sensitivity, specificity, and positive and negative predictive values of CCT for the assessment of coronary artery stenosis (<50% or ≥50% stenosis) in patients who underwent conventional coronary angiography. RESULTS We included 104 patients (73 men, aged 64 …
Retroauricular skin: a flaps bank for ear reconstruction.
2006
Retroauricular skin: a flaps bank for ear reconstruction. Cordova A, D'Arpa S, Pirrello R, Giambona C, Moschella F. Source Cattedra di Chirurgia Plastica e Ricostruttiva, Dipartimento di Discipline Chirurgiche ed Oncologiche, Università degli Studi di Palermo, Via del Vespro 129, 90127 - Palermo, Italy. adriana.cordova@excite.com Abstract BACKGROUND: The retroauricular skin has always been given much attention by the reconstructive surgeon for ear and face reconstruction because it is richly vascularised, as many anatomical investigations show, it is hidden behind the ear, its skin is very similar to that of ear and face. All these reasons make it an ideal donor site for ear reconstruction.…
Detection of flap venous and arterial occlusion using interstitial glucose monitoring in a rodent model.
2010
Background: Free tissue transfer necessitates vigilant postoperative monitoring for vessel occlusion. Unfortunately, most monitoring methods require experienced personnel and are expensive to use. Furthermore, many tests have low sensitivity, low specificity, or significant delay between vessel occlusion and detection. The authors report on a novel method of tissue monitoring that avoids these limitations by tracking interstitial glucose concentration. Methods: Vertical rectus abdominis myocutaneous flaps were elevated in adult rats based on the superior epigastric vessels. Interstitial glucose within the flaps was monitored using a transcutaneous sensor. Interstitial glucose was recorded f…
Cystatin C and cardiovascular mortality in patients with coronary artery disease and normal or mildly reduced kidney function: results from the Ather…
2009
Aims Chronic kidney disease is associated with increased risk of cardiovascular disease. Cystatin C is a promising marker to reliably mirror renal function. The role of cystatin C in patients with coronary artery disease (CAD) and normal or mildly reduced kidney function is the subject of current investigation. Methods and results In 2162 patients, over the whole spectrum of CAD, baseline cystatin C concentrations were measured. Patients with an estimated glomerular filtration rate of ≤60 mL/min per 1.73 m2 ( n = 295) were excluded. In patients with complete follow-up information ( n = 1827), 66 cardiovascular deaths were registered during a median follow-up of 3.65 years. Logarithmically t…
The carotid pulse check revisited: What if there is no pulse?
2000
This study was undertaken to evaluate the diagnostic accuracy and time required by first responders to assess the carotid pulse in potentially pulseless patients. We conducted a prospective, randomized study of first responders (n = 206; four different training levels) and were blinded as to the patients' conditions in the cardiac operating rooms of a university hospital. Sixteen patients underwent coronary artery bypass surgery on nonpulsatile cardiopulmonary bypasses. Carotid pulse check was performed either during pulsatile (spontaneous) or during nonpulsatile (extracorporeal) circulation. Patients' hemodynamic status at the time of assessment, diagnostic accuracy of the first responders…
Apoptosis is not involved in the mechanism of myocardial dysfunction after resuscitation in a rat model of cardiac arrest and cardiopulmonary resusci…
2010
OBJECTIVE To investigate the presence of apoptosis after the global myocardial ischemia of cardiopulmonary resuscitation and the regional myocardial ischemia after left anterior descending coronary artery occlusion and relate it to the severity of postresuscitation myocardial dysfunction. DESIGN Prospective animal study. SETTING University-affiliated animal research laboratory. SUBJECTS Male Sprague-Dawley rats. INTERVENTIONS Fifteen male Sprague-Dawley rats weighing 450-550 g were randomized to: (1) 8 mins of untreated cardiac arrest followed by 6 mins of cardiopulmonary resuscitation; (2)left anterior descending coronary artery occlusion for 45 mins followed by 4 hrs of reperfusion; and (…
Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in an…
2013
Objective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slices/collimation 64x0.625 mm, temporal resolution 210 ms, pitch 0.2) was performed after intracoronary injection of a saline solution, and solutions of a dimeric isosmolar contrast medium (Iodixanol 320 mgl ml(-1)) and a monomeric high-iodinated contrast medium (Iomeprol 400 mgl ml(-1)) with dilutions of 1/80 (low concentration), 1/50 (medium concentration), 1/40 (high concentration) and 1/20 (very high concent…