Search results for "Biomedical"

showing 10 items of 2328 documents

Dental wear proxy correlation in a long-term feeding experiment on sheep ( Ovis aries )

2021

Dietary reconstruction in vertebrates often relies on dental wear-based proxies. Although these proxies are widely applied, the contributions of physical and mechanical processes leading to meso- and microwear are still unclear. We tested their correlation using sheep ( Ovis aries , n = 39) fed diets of varying abrasiveness for 17 months as a model. Volumetric crown tissue loss, mesowear change and dental microwear texture analysis (DMTA) were all applied to the same teeth. We hereby correlate: (i) 46 DMTA parameters with each other, for the maxillary molars (M1, M2, M3), and the second mandibular molar (m2); (ii) 10 mesowear variables to each other and to DMTA for M1, M2, M3 and m2; and (…

0106 biological sciencesOrthodonticsMolar0303 health sciencesFuture studiesbiologyChemistryDental WearBiomedical EngineeringBiophysicsBioengineeringbiology.organism_classification010603 evolutionary biology01 natural sciencesBiochemistryMesowearBiomaterialsCorrelation03 medical and health sciencesstomatognathic systemProxy (statistics)Mandibular molarOvis030304 developmental biologyBiotechnologyJournal of The Royal Society Interface
researchProduct

Engineering CRISPR guide RNA riboswitches for in vivo applications

2019

CRISPR-based genome editing provides a simple and scalable toolbox for a variety of therapeutic and biotechnology applications. Whilst the fundamental properties of CRISPR proved easily transferable from the native prokaryotic hosts to eukaryotic and multicellular organisms, the tight control of the CRISPR-editing activity remains a major challenge. Here we summarise recent developments of CRISPR and riboswitch technologies and recommend novel functionalised synthetic-gRNA (sgRNA) designs to achieve inducible and spatiotemporal regulation of CRISPR-based genetic editors in response to cellular or extracellular stimuli. We believe that future advances of these tools will have major implicati…

0106 biological sciencesRiboswitchComputer scienceGenetic enhancementBiomedical EngineeringBioengineeringComputational biology01 natural sciences03 medical and health sciencesSynthetic biologyGenome editing010608 biotechnologyHumansCRISPRClustered Regularly Interspaced Short Palindromic RepeatsGuide RNAQH426030304 developmental biologyGene Editing0303 health sciencesReproducibility of ResultsRNAMulticellular organismRiboswitchGenetic EngineeringRNA Guide KinetoplastidaBiotechnologyCurrent Opinion in Biotechnology
researchProduct

Impact loading history modulates hip fracture load and location : A finite element simulation study of the proximal femur in female athletes

2018

Sideways falls impose high stress on the thin superolateral cortical bone of the femoral neck, the region regarded as a fracture-prone region of the hip. Exercise training is a natural mode of mechanical loading to make bone more robust. Exercise-induced adaptation of cortical bone along the femoral neck has been previously demonstrated. However, it is unknown whether this adaption modulates hip fracture behavior. The purpose of this study was to investigate the influence of specific exercise loading history on fall-induced hip fracture behavior by estimating fracture load and location with proximal femur finite element (FE) models created from magnetic resonance images (MRI) of 111 women w…

02 engineering and technologyFinite element simulationWeight-Bearing0302 clinical medicinemurtumatreisiluuOrthopedics and Sports MedicineFemurOrthodonticsHip fractureluustomedicine.diagnostic_testbiologyProximal femurexerciseRehabilitationfallingfemoral neckta3142lonkkamurtumatBiomechanical Phenomenamedicine.anatomical_structureFemalevahvistaminenAdultFinite Element Analysis0206 medical engineeringBiomedical EngineeringBiophysics030209 endocrinology & metabolismbone strengthYoung Adult03 medical and health sciencesmedicineHumansFemoral neckHip Fracturesbusiness.industryAthletesMagnetic resonance imagingfinite element modelingmedicine.diseasebiology.organism_classification020601 biomedical engineeringAthletesImpact loadingAccidental FallsCortical bonebusinesshuman activitiesJournal of Biomechanics
researchProduct

Self-assembled multivalent (SAMul) ligand systems with enhanced stability in the presence of human serum

2019

Self-assembled cationic micelles are an attractive platform for binding biologically-relevant polyanions such as heparin. This has potential applications in coagulation control, where a synthetic heparin rescue agent could be a useful replacement for protamine, which is in current clinical use. However, micelles can have low stability in human serum and unacceptable toxicity profiles. This paper reports the optimi- sation of self-assembled multivalent (SAMul) arrays of amphiphilic ligands to bind heparin in competitive conditions. Specifically, modification of the hydrophobic unit kinetically stabilises the self-assembled nanostructures, preventing loss of binding ability in the presence of…

02 engineering and technologyheparinLigands01 natural sciencesMicelleGeneral Materials ScienceMicellesnanomaterialsMolecular StructurenanotechnologybiologyChemistrybiomaterialself-assemblyHeparinsimulation021001 nanoscience & nanotechnologyCholesterolhydrolysisThermodynamics0210 nano-technologyHydrophobic and Hydrophilic Interactionsbiomaterialsmedicine.drugBiocompatibilityCell Survivalmicellesexperimental characterizationserum albuminBiomedical EngineeringSerum albuminself-assembly; nanotechnology; biomaterials; simulation; experimental characterization010402 general chemistrySurface-Active Agentsthermodynamicsbiocompatibilitytoxicity testingAmphiphilemedicineHumansMTT assaycoagulationhydrophobicityHeparinLigandligandscholesteroltoxicitybinding capacityProtaminemolecular dynamicsNanostructures0104 chemical sciencesKineticsblood serumbiology.proteinBiophysicshuman cell linesanions
researchProduct

2018

<b><i>Background:</i></b> A major and complex challenge when trying to support individuals with dementia is meeting the needs of those who experience changes in behaviour and mood. <b><i>Aim:</i></b> To explore how a sensor measuring electrodermal activity (EDA) impacts assistant nurses’ structured assessments of problematic behaviours amongst people with dementia and their choices of care interventions. <b><i>Methods:</i></b> Fourteen individuals with dementia wore a sensor that measured EDA. The information from the sensor was presented to assistant nurses during structured assessments of problematic behaviours. The e…

020205 medical informaticsCognitive Neuroscience02 engineering and technologymedicine.diseasePeer review03 medical and health sciencesPsychiatry and Mental health0302 clinical medicineMood0202 electrical engineering electronic engineering information engineeringmedicineDementiaNursing homesPsychology030217 neurology & neurosurgeryBiomedical sciencesClinical psychologyDementia and Geriatric Cognitive Disorders Extra
researchProduct

A validity and reliability study of Conditional Entropy Measures of Pulse Rate Variability

2019

In this work, we present the feasibility to use a simpler methodological approach for the assessment of the short-term complexity of Heart Rate Variability (HRV). Specifically, we propose to exploit Pulse Rate Variability (PRV) recorded through photoplethysmography in place of HRV measured from the ECG, and to compute complexity via a linear Gaussian approximation in place of the standard model-free methods (e.g., nearest neighbor entropy estimates) usually applied to HRV. Linear PRV-based and model-free HRV-based complexity measures were compared via statistical tests, correlation analysis and Bland-Altman plots, demonstrating an overall good agreement. These results support the applicabil…

020205 medical informaticsComputer scienceEntropy0206 medical engineeringValidity02 engineering and technologySettore ING-INF/01 - ElettronicaElectrocardiographyPulse Rate Variability (PRV)Heart RatePhotoplethysmogram0202 electrical engineering electronic engineering information engineeringHumansEntropy (information theory)Heart rate variabilityEntropy (energy dispersal)Time seriesPhotoplethysmographyEntropy (arrow of time)Statistical hypothesis testingConditional entropyEntropy (statistical thermodynamics)Reproducibility of ResultsHeart Rate Variability (HRV)020601 biomedical engineeringSettore ING-INF/06 - Bioingegneria Elettronica E InformaticacomplexityAlgorithmEntropy (order and disorder)2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
researchProduct

The use of accelerometry to evaluate the BMX cycling starting hill. Effect of the Q-Ring™ on the acceleration profile

2020

Accelerometers are becoming popular in sport performance, as they are easy to wear, affordable, and usable in the field. Eccentric chainrings have been commercialised to improve pedalling performance, but little is known about their possible effects in the first pedal strokes (PS) of maximal sprint starts. To analyse the effects of the Q-Ring chainring (Q) on pedalling mechanics and performance in the BMX starting hill, 12 Spanish-National-Team BMX athletes performed 3 maximal sprints comparing Q vs No-Q. Time was measured in the first three meters. Acceleration output was registered with a triaxial 6 g accelerometer (200 Hz) in the first four PS. Discrete time, acceleration and statistical…

0206 medical engineeringBiomechanicsPhysical Therapy Sports Therapy and Rehabilitation030229 sport sciences02 engineering and technologyAccelerometer020601 biomedical engineering03 medical and health sciencesAcceleration0302 clinical medicineSprintEccentricOrthopedics and Sports MedicineCyclingSimulationMathematicsSports Biomechanics
researchProduct

Influence of short implants geometry on primary stability.

2018

Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…

0206 medical engineeringDentistry02 engineering and technologyBone and BonesDental Prosthesis Retention03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral Dentistrybusiness.industryResearchDental Implantation Endosseousfood and beverages030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringShort implantsOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgerybusiness
researchProduct

Bleaching efficacy of at home 16% carbamide peroxide. A long-term clinical follow-up study.

2019

OBJECTIVE To assess the whitening efficacy of a 16% carbamide peroxidase (CP) gel after 42 months of clinical follow-up. MATERIALS AND METHODS A retrospective clinical study was carried out involving 95 participants. CP 16% was applied for 90 minutes a day for 4 weeks using individualized trays. Tooth color was assessed using spectrophotometry at baseline, 1 week after the end of treatment, and every 6 months until completing 42 months of follow-up. Color parameters were compared using analysis of variance for repeated measures. The analysis by teeth groups was performed using two-way ANOVA. RESULTS The mean baseline L* was 81.7 ± 5.2 versus 83.6 ± 8.8 after 42 months (P<.01). L* showed a d…

0206 medical engineeringDentistryColor02 engineering and technologyCarbamide PeroxideRetrospective data03 medical and health sciences0302 clinical medicineTooth BleachingMedicineUreaClinical significanceTooth Bleaching AgentsGeneral DentistryRetrospective StudiesTooth whiteningbusiness.industryFollow up studiesRepeated measures design030206 dentistryHydrogen Peroxide020601 biomedical engineeringPeroxidesTooth colorAnalysis of varianceCarbamide peroxidebusinessFollow-Up StudiesJournal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]REFERENCES
researchProduct

Definition of the thermographic regions of interest in cycling by using a factor analysis

2016

Abstract Research in exercise physiology using infrared thermography has increased in the last years. However, the definition of the Regions of Interest (ROIs) varies strongly between studies. Therefore, the aim of this study was to use a factor analysis approach to define highly correlated groups of thermographic ROIs during a cycling test. Factor analyses were performed based on the moment of measurement and on the variation of skin temperatures as a result of the cycling exercise. 19 male participants cycled during 45 min at 50% of their individual peak power output with a cadence of 90 rpm. Infrared thermography was used to measure skin temperatures in sixteen ROIs of the trunk and lowe…

0206 medical engineeringSkin temperature02 engineering and technologyCondensed Matter Physics020601 biomedical engineering01 natural sciencesTrunkAtomic and Molecular Physics and Opticsnervous system diseasesElectronic Optical and Magnetic Materials010309 opticsMoment (mathematics)nervous systemmental disorders0103 physical sciencesThermographyPrincipal component analysisExercise physiologyCyclingCadencepsychological phenomena and processesMathematicsBiomedical engineeringInfrared Physics &amp; Technology
researchProduct