Search results for "Butabarbital"
showing 4 items of 4 documents
Determination of amobarbital and secobarbital in plasma samples using micellar liquid chromatography
2000
A new liquid chromatographic procedure for the determination of amobarbital and secobarbital in plasma samples is proposed. The method uses a Spherisorb octadecylsilane ODS-2 C18 analytical column, a guard column of similar characteristics and 0.04 M CTAB solution buffered at pH 7.5 containing 3% 1-propanol as micellar mobile phase. The UV detection was carried out at 250 nm. Butabarbital was used as internal standard. Plasma samples preparation only required adequate dilution with the mobile phase before injection into the chromatographic system. The limits of detection were 0.2 and 0.4 mg/L for amobarbital and secobarbital, respectively. The proposed method allows the determination of amo…
Determination of phenobarbital in plasma by micellar liquid chromatography
2000
A new liquid chromatographic procedure for the determination of phenobarbital in plasma samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C(18) analytical column, a guard column of similar characteristics, and a 0.03 M CTAB-3% 1-propanol at pH 7 mobile phase. The UV detector was set at 250 nm. Butabarbital was used as internal standard. Sample preparation only required the addition to the plasma samples of a 0.1 M SDS solution at pH 3 and centrifugation before injection into the chromatographic system. The limit of detection was 0.83 microg/mL of phenobarbital in plasma samples. The coefficients of variation were lower than 7. 5%.
Determination of barbiturates in urine by micellar liquid chromatography and direct injection of sample.
2000
Abstract A liquid chromatographic procedure for the determination of six barbiturates (barbital, diallyl barbituric acid, phenobarbital, butabarbital, amobarbital and pentobarbital) in urine samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C 18 analytical column and a guard column of similar characteristics. The UV detector was set at 240 nm. A study to select adequate composition of the micellar mobile phase for the separation of these compounds in urine samples is performed. Maximum resolution was achieved with a 0.07 M sodium dodecylsulphate-0.3% propanol at pH 7.4 eluent. Limits of detection at 240 nm were ranged between 0.13 μg ml −1 for diallyl barbit…
Effect of Injectable or Inhalational Anesthetics and of Neuroleptic, Neuroleptanalgesic, and Sedative Agents on Tumor Blood Flow
1988
Among other parameters, varying blood flow values may be responsible for tumor-to-tumor variabilities in the radiobiologically hypoxic cell fraction of experimental rodent tumors. To test whether changes in tumor blood flow may be caused by anesthetic agents often used in radiobiology, the effect of injectable and inhalational anesthetics and of neuroleptic, neuroleptanalgesic, and sedative agents on blood flow in subcutaneous DS-carcinosarcomas implanted in Sprague-Dawley rats has been investigated using the 85Kr clearance technique. In conscious rats, 20-100 min after animal instrumentation mean blood flow is 0.62 +/- 0.17 ml/g/min (mean +/- SD) in 0.75 +/- 0.15 g tumors at a mean arteria…