Search results for "CT imaging"
showing 10 items of 31 documents
Symmetry of root and root canal morphology of mandibular incisors: A cone-beam computed tomography study
2019
Background Aim of this study was to analyze the root canal configuration in mandibular central and lateral incisors in vivo using cone-beam computed tomography (CBCT) imaging. Material and methods A total of 487 mandibular central incisors and 491 mandibular lateral incisors from 250 patients were examined using CBCT imaging, previously taken for diagnosis and treatment. The number of roots, root canal system configuration, presence of apical confluences, distance between confluences and radiographic root end, symmetry between left and right elements were recorded and statistically analyzed. Results All the examined teeth presented only one root. No significant differences were found betwee…
Italian multicenter, prospective study to evaluate the negative predictive value of 16- and 64-slice MDCT imaging in patients scheduled for coronary …
2009
This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (> or =16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off…
Water dynamics in different biochar fractions.
2014
Biochar is a carbonaceous porous material deliberately applied to soil to improve its fertility. The mechanisms through which biochar acts on fertility are still poorly understood. The effect of biochar texture size on water dynamics was investigated here in order to provide information to address future research on nutrient mobility towards plant roots as biochar is applied as soil amendment. A poplar biochar has been stainless steel fractionated in three different textured fractions (1.0-2.0 mm, 0.3-1.0 mm and0.3 mm, respectively). Water-saturated fractions were analyzed by fast field cycling (FFC) NMR relaxometry. Results proved that 3D exchange between bound and bulk water predominantly…
Japanese Radiation Research Society
2017
Computed tomography (CT) is an essential tool in modern medicine and is frequently used to diagnose a wide range of conditions, particularly in industrial countries, such as Japan and Germany. However, markedly higher doses of ionizing radiation are delivered during CT imaging than during conventional X-ray examinations. To assess pediatric CT practice patterns, data from three university hospital databases (two in Japan and one in Germany) were analyzed. Anonymized data for patients aged 0 to 14 years who had undergone CT examinations between 2008 and 2010 were extracted. To assess CT practice, an interdisciplinary classification scheme for CT indications, which incorporated the most commo…
Direct Imaging of Chiral Domain Walls and Néel‐Type Skyrmionium in Ferrimagnetic Alloys
2021
International audience; The evolution of chiral spin structures is studied in ferrimagnet Ta/Ir/Fe/GdFeCo/Pt multilayers as a function of temperature using scanning electron microscopy with polarization analysis (SEMPA). The GdFeCo ferrimagnet exhibits pure right-hand Néel-type domain wall (DW) spin textures over a large temperature range. This indicates the presence of a negative Dzyaloshinskii-Moriya interaction (DMI) that can originate from both the top Fe/Pt and the Co/Pt interfaces. From measurements of the DW width, as well as complementary magnetic characterization, the exchange stiffness as a function of temperature is ascertained. The exchange stiffness is surprisingly mostly const…
Direct imaging of current-induced antiferromagnetic switching revealing a pure thermomagnetoelastic switching mechanism in NiO
2021
We unambiguously identify the origin of the current-induced magnetic switching of insulating antiferromagnet/heavy metal bilayers. Previously, different reorientations of the Neel order for the same current direction were reported for different device geometries and different switching mechanisms were proposed. Here, we combine concurrent electrical readout and optical imaging of the switching of antiferromagnetic domains with simulations of the current-induced temperature and strain gradients. By comparing the switching in specially engineered NiO/Pt device and pulsing geometries, we can rule out spin-orbit torque based mechanisms and identify a thermomagnetoelastic mechanism to dominate t…
Presacral Myelolipoma
2014
Many reports have described adrenal myelolipomas but there have been only a few reports of extra-adrenal myelolipomas. We describe a 74-year-old woman who came to our observation for MRI of the lumbar spine for typical lumbar back pain. In addition to signs of mild scoliosis and spondylo disc arthrosis, MR imaging revealed a presacral mass showing a heterogeneously high signal in all pulse sequences and almost completely suppressed on inversion recovery sequences for fat tissue. CT imaging confirmed the fatty nature of the lesion and no signs of bone involvement. These findings were most consistent with a diagnosis of a rare presacral myelolipoma as confirmed at histopathologic analysis. T…
Determination of Cochlear Duct Length With 3D Versus Two-dimensional Methods: A Retrospective Clinical Study of Imaging by Computed Tomography and Co…
2021
BACKGROUND The aim of this study was to compare three different methods for measurement of cochlear duct length (CDL) in the clinical setting for two different imaging modalities, namely computed tomography (CT) and cone-beam computed tomography (CBCT). PATIENTS AND METHODS One hundred temporal bone data sets (CT: n=50; CBCT: n=50) of non-malformed cochleae were retrospectively analyzed using three different CDL estimation techniques: 3D curved multiplanar reconstruction (cMPR), 2D cMPR and the A-value formula. RESULTS The data sets belonged to 60 patients (34 males, 26 females; mean age=50.28±18.58 years). For both imaging modalities, application of the 3D cMPR estimation technique led to …
Imaging Trapped Ion Structures via Fluorescence Cross-Correlation Detection
2021
Cross-correlation signals are recorded from fluorescence photons scattered in free space off a trapped ion structure. The analysis of the signal allows for unambiguously revealing the spatial frequency, thus the distance, as well as the spatial alignment of the ions. For the case of two ions we obtain from the cross-correlations a spatial frequency ${f}_{\text{spatial}}=1490\ifmmode\pm\else\textpm\fi{}{2}_{\mathrm{stat}}\ifmmode\pm\else\textpm\fi{}{8}_{\mathrm{syst}}\text{ }\text{ }{\mathrm{rad}}^{\ensuremath{-}1}$, where the statistical uncertainty improves with the integrated number of correlation events as ${N}^{\ensuremath{-}0.51\ifmmode\pm\else\textpm\fi{}0.06}$. We independently deter…
SOLAR DYNAMICS OBSERVATORY DISCOVERS THIN HIGH TEMPERATURE STRANDS IN CORONAL ACTIVE REGIONS
2011
One scenario proposed to explain the million degrees solar corona is a finely-stranded corona where each strand is heated by a rapid pulse. However, such fine structure has neither been resolved through direct imaging observations nor conclusively shown through indirect observations of extended superhot plasma. Recently it has been shown that the observed difference in appearance of cool and warm coronal loops (~1 MK, ~2-3 MK, respectively) -- warm loops appearing "fuzzier" than cool loops -- can be explained by models of loops composed of subarcsecond strands, which are impulsively heated up to ~10 MK. That work predicts that images of hot coronal loops (>~6 MK) should again show fine s…