Search results for "Calibration curve"
showing 10 items of 99 documents
Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry
2000
Abstract A method is proposed for boron determination in ceramic materials, boracic raw materials and ceramics frits of different compositions by wavelength dispersive X-ray fluorescence technique. The instrumental conditions were studied and the sample preparation procedures were optimized. The reference method used was the potentiometric titration of mannitol–boric complex acid and the technique was optimized for the determination of B 2 O 3 in each of the materials used. The samples for XRF determination were obtained as pellets and as glass discs. For the pellets different binders were studied, such as mannitol and cellullose for the samples of raw materials, and polyvinylpirrolidone an…
Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy
2020
GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.
Measuring the refractive state of an eye based on the intensity of the retinal reflex
2017
AbstractWhen examining the fundus of the eye with an ophthalmoscope, the intensity of the retinal reflex depends on the refractive state of the eye. In this study, application of this phenomenon for measuring the refractive state of the eye is demonstrated. First, a calibration curve relating the intensity of the retinal reflex and the refractive state was obtained using a model eye. Next, the intensity of the retinal reflex was measured while subjects were viewing a checker-board pattern, the distance of which was varied within the range from 0.17 to 1 m. Further, the relation between the refractive state and the optical power of the stimulus could be determined based on the measured light…
Influence of temperature on the calibration curves in IRMA for neuron specific enolase and its physicochemical interpretation
2009
Abstract Background immunoradiometric assay (IRMA) is one of the principal methods used for the analytical determination of neuron specific enolase (NSE) concentration. We studied the influence of temperature on the calibration curves obtained by this method, and a physicochemical justification based on two theoretical models is proposed. Material and methods we used a commercially available RIA kit for NSE and a gamma counter. Data was analysed using Statistical software. Results and discussion activity bound to the antibody increases with temperature, producing results that are consistent with two modifications to the four parameter and Langmuir equations. Conclusions the two models used …
Size-Exclusion Chromatographic Determination of Polymer Molar Mass Averages Using a Fractal Calibration
2005
The characterization of polymers by size-exclusion chromatography basically consists of the determination of the weight-average molar mass (Mw), number-average molar mass (Mn), and polydispersity index (I). An accurate estimation of these magnitudes requires the use of a reliable and trusted calibration curve. Three procedures for building up a calibration curve are analyzed in this work. The first is the classical universal calibration (UC), based on the elution of tetrahydrofuran-polystyrene in a system as reference. The second is based on the proper calibration curve made with standards of the sample under study. However, two main drawbacks arise when using these methodologies: the nonfu…
Determination of mass attenuation coefficient by numerical absorption calibration with Monte-Carlo simulations at 59.54 keV
2016
Abstract This study presents a numerical method in order to determine the mass attenuation coefficient of a sample with an unknown chemical composition at low energy. It is compared with two experimental methods: a graphic method and a transmission method. The method proposes to realise a numerical absorption calibration curve to process experimental results. Demineralised water with known mass attenuation coefficient ( 0.2066 cm 2 g − 1 at 59.54 keV) is chosen to confirm the method. 0.1964 ± 0.0350 cm 2 g − 1 is the average value determined by the numerical method, that is to say less than 5% relative deviation compared to more than 47% for the experimental methods.
Measurement of the b hadron lifetime with the dipole method
1993
A measurement of the average lifetime of b hadrons has been performed with the dipole method on a sample of 260000 hadronic Z decays recorded with the ALEPH detector during 1991. The dipole is the distance between the vertices built in the opposite hemispheres. The mean dipole is extracted from all the events without attempting b enrichment. Comparing the average of the data dipole distribution with a Monte Carlo calibration curve obtained with different b lifetimes, an average b hadron lifetime of 1.51 +/- 0.08 ps is extracted. RI ANTONELLI, ANTONELLA/C-6238-2011; Buttar, Craig/D-3706-2011; Stahl, Achim/E-8846-2011; Passalacqua, Luca/F-5127-2011; Murtas, Fabrizio/B-5729-2012; St.Denis, Ric…
Direct Analysis of Psilocin and Muscimol in Urine Samples Using Single Drop Microextraction Technique In-Line with Capillary Electrophoresis
2020
The fully automated system of single drop microextraction coupled with capillary electrophoresis (SDME-CE) was developed for in-line preconcentration and determination of muscimol (MUS) and psilocin (PSC) from urine samples. Those two analytes are characteristic active metabolites of Amanita and Psilocybe mushrooms, evoking visual and auditory hallucinations. Study analytes were selectively extracted from the donor phase (urine samples, pH 4) into the organic phase (a drop of octanol layer), and re-extracted to the acidic acceptor (background electrolyte, BGE), consisting of 25 mM phosphate buffer (pH 3). The optimized conditions for the extraction procedure of a 200 µ
Study on resolution capacity and secondary mechanisms of three different TSK gels for organic SEC.
2005
A comparative study on the elution behavior in size-exclusion chromatography (SEC) of three polymeric TSK gel packings, named H, H H R , and H X L types, is performed. The deviations of the universal calibration (u.c.) curves of seven solvent-polymer systems show evidence that the existence of secondary effects accompanying the main SEC mechanism. These secondary mechanisms are a consequence of the binary enthalpic interactions between the different components of the chromatographic system, such as polymer-solvent, polymer-gel and solvent-gel. However, in the present case, the observed deviations from a unique u.c. curve can mainly be attributed to adsorption of polymeric solutes (analytes)…
Determination of Phenylephrine Hydrochloride by Flow Injection Analysis with Chemiluminescence Detection
2001
Abstract A new method is proposed for the determination of phenylephrine hydrochloride by flow injection analysis with direct chemiluminescence detection. The method is based on the oxidation of the drug by potassium permanganate in sulfuric acid medium at 80°C. The calibration graph is linear over the range 0.03–8 ppm phenylephrine hydrochloride, with a relative standard deviation (n = 51, 0.5 ppm) of 1.1% and sample throughput of 134/h. The influence of 38 different foreign compounds was tested, and the method was applied to the determination of phenylephrine hydrochloride in 8 different pharmaceutical formulations.