Search results for "Calibration"
showing 10 items of 890 documents
Exploring Training Options for RF Sensing Using CSI
2018
This work analyzes human behavior recognition approaches using WiFi channel state information from the perhaps less usual point of view of training and calibration needs. With the help of selected literature examples, as well as with more detailed experimental insights on our own Doppler spectrum-based approach for physical motion/presence/cardinality detection, we first classify the diverse forms of training so far employed into three main categories (trained, trained-once, and training-free). We further discuss under which conditions it is possible to move toward lighter forms of calibration or even succeed in devising fully untrained model-based solutions. Our take home messages are main…
Replication Data for: Automatic Calibration of an Industrial RGB-D Camera Network using Retroreflective Fiducial Markers.
2019
Replication Data in the form of a Robot Operating System (ROS) recording (ROS-bag) to replicate the results of the paper "Automatic Calibration of an Industrial RGB-D Camera Network using Retroreflective Fiducial Markers." The contents of the dataset are timestamped images and point clouds recorded from six different sensor nodes.
INTEGRAL/SPI ground calibration
2003
Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the effective detection area, the spectral resolution and the angular resolution. Absolute determination of the effective area has been obtained from simulations and measurements. At 1 MeV, the effective area is 65 cm^2 for a point source on the optical axis, the spectral resolution ~2.3 keV. The angular resolution is better than 2.5 deg and the source separation capability about 1 deg. Some temperature dependant parameters will require permanent in-flight calibration.
The X-Ray Telescope (XRT) for the Hinode Mission
2007
著者人数:29名
Simultaneous determination of 4-nitroanisole, 4-nitrophenol, and 4-nitrocatechol by phase-sensitive ac polarography.
1977
Abstract Phase‐sensitive ac polarography was applied to the simultaneous quantitative determination of 4‐nitroanisole, 4‐nitrophenol and 4‐nitrocatechol in alkaline solutions. Certain experimental precautions are necessary to determine each compound in the presence of the other two. Thus, 4‐nitrocatechol is determined indirectly by forming a yellow ratio chelate with cupric ions, whereas 4‐nitroanisole is determined directly by the reduction waves of the nitro group. For the determination of 4‐nitrophenol, the interference by the simultaneously present 4‐nitrocatechol must be eliminated by masking it by the addition of magnesium ions. The method described permits a qualitative and quantitat…
FIA-spectrophotometric determination of N-substituted phenothiazine derivatives by oxidation with a solid-phase reactor of manganese dioxide incorpor…
1995
Abstract The determination of several N -substituted phenothiazine derivatives was carried out by the reaction of the drug with managanese dioxide entrapped in a polymeric material in a packed-bed reactor; the oxidized drug was monitored at λ max . The calibration graph is linear over the range 5–50 μg/ml of phenothiazine derivatives with a relative standard deviation of 0.5–1% (at 10 μg/ml) and sample throughput of 40–48 h −1 . The influence of foreign compounds was studied and the method was applied to the determination of six different phenothiazine derivatives in pharmaceutical formulations.
FIA-AAS determination of salicylic acid by a solid-phase reactor of copper carbonate incorporated in polyester resin beads.
1994
Abstract The determination of salicylic acid was carried out by reaction of the drug with copper carbonate entrapped in a polymeric material in a solid-phase reactor; the released cupric ions were monitored by flame atomic absorption at 324.8 nm. The calibration graph is linear over the range 4.0–75 μg ml −1 of salicylic acid, with a relative standard deviation of less than 1.5% and a sample throughout of 257 h −1 . The influence of foreign compounds was studied and the method was applied to the determination of salicylic acid content in two different pharmaceutical formulations.
Copper carbonate as a solid-bed reactor for spectrophotometric determination of doxycycline and oxytetracycline in an unsegmented continuous flow ass…
1993
The FIA-spectrophotometric determination of doxycycline was carried out by reaction of the drug with cupric ions entrapped in a polymeric material in a packed-bed reactor: the complex formed was then injected into a manifold with an alkaline solution as carrier. The developed colour was monitored at 395.0 nm. The method was applied to the determination of doxycycline in different pharmaceutical formulations. The calibration graph for doxycycline hyclate was linear over the range 10.0-80.0 mg ml-1 (n = 8) with a relative standard deviation of 1.4% (at 25 mg ml-1) and a sample throughput of 128 h-1. The proposed procedure was also applied to the determination of oxytetracycline in pharmaceuti…
Uptake of polymeric nanoparticles in a human induced pluripotent stem cell-based blood-brain barrier model: Impact of size, material, and protein cor…
2021
The blood–brain barrier (BBB) maintains the homeostasis of the central nervous system, which is one of the reasons for the treatments of brain disorders being challenging in nature. Nanoparticles (NPs) have been seen as potential drug delivery systems to the brain overcoming the tight barrier of endothelial cells. Using a BBB model system based on human induced pluripotent stem cells (iPSCs), the impact of polymeric nanoparticles has been studied in relation to nanoparticle size, material, and protein corona. PLGA [poly(lactic-co-glycolic acid)] and PLLA [poly(d,l-lactide)] nanoparticles stabilized with Tween® 80 were synthesized (50 and 100 nm). iPSCs were differentiated into human brain m…
An immunoassay for terbutryn using direct hapten linkage to a glutaraldehyde network on the polystyrene surface of standard microtiter plates.
2001
2-Aminobutylamino-4-ethylamino-6-isopropylamino-1,3,5-triazine (ABA-atrazine) has been synthesized and used as a coating hapten in an immunoassay with a monoclonal antibody against terbutryn. Coating was achieved by covalently linking ABA-atrazine to a glutaraldehyde polymer network directly bound to the polystyrene surface of a standard 96-well microtiter plate. The assay was carefully optimized. In particular, the coating hapten concentration had a strong effect on the ELISA sensitivity. By including a pre-incubation step a low test midpoint (IC50-value) of 0.130 microg L(-1) was achieved. As far as we are aware this is the most sensitive ELISA for terbutryn yet reported. The coating-hapt…