Search results for "Cardiac"
showing 10 items of 1495 documents
Follow-up after transanal endoscopic microsurgery or transanal excision of large benign rectal polyps
1998
Methods: Between January 1986 and December 1995, 238 patients with benign rectal polyps under-went either transanal endoscopic microsurgery (n = 226) or transanal excision (n = 12) at the Clinic of General and Abdominal Surgery, Johannes Gutenberg-University, Mainz. Results: Mean polyp size was 4.2 cm; 89.1% of polyps measured more than 2 cm in diameter. In 89.1% of cases, histological analysis revealed polyps containing tubulovillous or villous adenomas. Synchronous colonic polyps were detected in 12.5% of patients. Follow-up data are available on 222 patients (94%). At follow-up examination, 169 of the 193 surviving patients (87.6%) were recurrence free. Seven of 193 patients (3.6%) had d…
Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning
1997
The purpose of this study was to evaluate the relation of transthoracic three- and two-dimensional echocardiographic left ventricular volumetry to cineventriculographic volumetry. Twenty-five patients with distorted left ventricles were included in the study. To demonstrate the impact of acquiring data by rotational scanning, we performed three- and two-dimensional echocardiography in 36 latex ventricles with data acquisition in different areas of the ultrasound sectors. Interobserver and intraobserver variability were calculated to test for reproducibility. The three-dimensional imaging system consisted of a rotation motor device, a transthoracic 2.5 MHz transducer, a conventional ultrasou…
Acute performance evaluation of a new ventricular automatic capture algorithm
2006
Aims This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. Methods and results During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA™ pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients…
Human Dental Pulp Stem Cells Improve Left Ventricular Function, Induce Angiogenesis, and Reduce Infarct Size in Rats with Acute Myocardial Infarction
2008
Abstract Human dental pulp contains precursor cells termed dental pulp stem cells (DPSC) that show self-renewal and multilineage differentiation and also secrete multiple proangiogenic and antiapoptotic factors. To examine whether these cells could have therapeutic potential in the repair of myocardial infarction (MI), DPSC were infected with a retrovirus encoding the green fluorescent protein (GFP) and expanded ex vivo. Seven days after induction of myocardial infarction by coronary artery ligation, 1.5 × 106 GFP-DPSC were injected intramyocardially in nude rats. At 4 weeks, cell-treated animals showed an improvement in cardiac function, observed by percentage changes in anterior wall thic…
Lorcainide; II. Plasma concentration-effect relationship
1979
Categorizing the Role of Respiration in Cardiovascular and Cerebrovascular Variability Interactions
2022
Objective: Respiration disturbs cardiovascular and cerebrovascular controls but its role is not fully elucidated. Methods: Respiration can be classified as a confounder if its observation reduces the strength of the causal relationship from source to target. Respiration is a suppressor if the opposite situation holds. We prove that a confounding/suppression (C/S) test can be accomplished by evaluating the sign of net redundancy/synergy balance in the predictability framework based on multivariate autoregressive modelling. In addition, we suggest that, under the hypothesis of Gaussian processes, the C/S test can be given in the transfer entropy decomposition framework as well. Experimental p…
The Disease-Specific Phenotype in Cardiomyocytes Derived from Induced Pluripotent Stem Cells of Two Long QT Syndrome Type 3 Patients
2013
Long QT syndromes (LQTS) are heritable diseases characterized by prolongation of the QT interval on an electrocardiogram, which often leads to syncope and sudden cardiac death. Here we report the generation of induced pluripotent stems (iPS) cells from two patients with LQTS type 3 carrying a different point mutation in a sodium channel Nav1.5 (p.V240M and p.R535Q) and functional characterization of cardiomyocytes (CM) derived from them. The iPS cells exhibited all characteristic properties of pluripotent stem cells, maintained the disease-specific mutation and readily differentiated to CM. The duration of action potentials at 50% and 90% repolarization was longer in LQTS-3 CM as compared t…
Cardiac surgery outcomes in patients with coronavirus disease 2019 (COVID-19): A case-series report
2020
Abstract Objective The impact of coronavirus disease 2019 (COVID-19) on the postoperative course of patients after cardiac surgery is unknown. We experienced a major severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak in our cardiac surgery unit, with several patients who tested positive early after surgery. Here we describe the characteristics, postoperative course, and laboratory findings of these patients, along with the fate of the health care workers. We also discuss how we reorganize and reallocate hospital resources to resume the surgical activity without further positive patients. Methods After diagnosis of the first symptomatic patient, surgery was suspended. Naso…
Relationship between device acceptance and patient-reported outcomes in Left Ventricular Assist Device (LVAD) recipients
2019
AbstractThe number of Left Ventricular Assist Devices (LVADs) implanted each year is rising. Nevertheless, there are minimal data on device acceptance after LVAD implant, and on its relationship with patient-reported outcomes. We designed a cross-sectional study to address this knowledge gap and test the hypothesis that low device acceptance is associated with poorer quality of life, depression and anxiety. Self-report questionnaires were administered to assess quality of life (12-item Kansas City Cardiomyopathy Questionnaire quality of life subscale), level of anxiety (7-item Generalized Anxiety Disorder; GAD-7), level of depression (9-item Patient Health Questionnaire; PHQ-9) and device a…
Non-compact myocardium assessment by cardiac magnetic resonance: dependence on image analysis method
2018
To compare image analysis methods for the assessment of left ventricle non-compaction from cardiac magnetic resonance (CMR) imaging. CMR images were analyzed in 20 patients and 10 normal subjects. A reference model of the MR signal was introduced and validated based on image data. Non-compact (NC) myocardium size and distribution were assessed by tracing a single, continuous contour delimiting trabeculated region (Jacquier) or by one-by-one selection of trabeculae (Grothoff). The global non-compact/compact (NC/C) ratio, the NC mass, and the segmental NC/C ratio were assessed. Results were compared with the reference model. A significant difference between Grothoff and Jacquier approaches in…