Search results for "Cartridge"

showing 10 items of 20 documents

Experimental data of the laboratory investigation for the design of a new filter cartridge for water treatment

2019

Abstract The data provided here refers to the experimental laboratory investigation conducted in the Laboratory of Environmental and Maritime Hydraulics (LIDAM) of University of Salerno, Italy, with the aim of developing a new filtering cartridge for water treatment capable of overcoming the main inconveniences shown by usual commercial cartridges. Specifically, the proposed filtering cartridge is an economic, non-toxic, low-resistance and long-life cartridge, currently under a patent pending status, whose main advantage is to permit to significantly reduce, compared with the commercial cartridges, average head losses induced by the cartridge even for high clogging degrees, and to increase,…

0303 health sciencesMultidisciplinarybusiness.industryHydraulicsInstrumentationExperimental dataFilter (signal processing)lcsh:Computer applications to medicine. Medical informaticslaw.inventionClogging03 medical and health sciencesCartridge0302 clinical medicineEngineeringlawlcsh:R858-859.7Environmental scienceLocal pressureWater treatmentlcsh:Science (General)Process engineeringbusiness030217 neurology & neurosurgerylcsh:Q1-390030304 developmental biologyData in Brief
researchProduct

Selective determination of trimethylamine in air by liquid chromatography using solid phase extraction cartridges for sampling.

2004

Abstract The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn ( 20 mm ×2.1 mm i.d., packed with 30 μm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column ( 125 mm ×4 mm i.d., LiChrospher 100 RP18, 5 μm), and monitored at 262 nm. The method was applied to …

AnalyteAnalytical chemistryTrimethylamineChloroformateAir Pollutants OccupationalBuffersBiochemistryAnalytical ChemistryCartridgechemistry.chemical_compoundMethylaminesBoric AcidsSolid phase extractionDetection limitReproducibilityChromatographyOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineReference StandardsSolutionschemistryCalibrationIndicators and ReagentsSpectrophotometry UltravioletChromatography Liquid
researchProduct

Automated Photo-Induced Fluorescence Determination of Flumetsulam

2009

The present article deals with a new procedure for determination of the herbicide flumetsulam. The fluorimetric procedure is performed on the basis of photo-increased fluorimetric emission of the pesticide solution and by means of a multicommutation continuous-flow assembly. The alkaline solution containing the analyte is irradiated online and then directly forced through the fluorimeter flow cell. The analysis of different samples is completely automated, as the analyte separation was performed online by including a separation cartridge in the manifold. When dealing with solid samples (such as soil samples), the automation was completed by adding to the manifold the corresponding device fo…

AnalyteChromatographyAqueous solutionChemistryBiochemistry (medical)Clinical BiochemistryExtraction (chemistry)Fluorescence spectrometryAnalytical chemistryBiochemistryFluorescenceAnalytical ChemistryCartridgeFluorometerElectrochemistrySample preparationSpectroscopyAnalytical Letters
researchProduct

More about sampling and estimation of mercaptans in air samples

2013

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

AnalyteSorbentAir samplesAlkaliesHigh-performance liquid chromatographyAnalytical ChemistryCartridgeO-Phthalaldehydechemistry.chemical_compoundMercaptansQUIMICA ANALITICAHumansSulfhydryl CompoundsIsoleucineDerivatizationAir sampling systemFluorescent DyesAir PollutantsChromatographyAirSampling (statistics)DerivatizationSolutionsSpectrometry FluorescencechemistryReagentCalibrationHPLCo-PhthalaldehydeChromatography Liquid
researchProduct

Solid-Phase Extraction and Clean-Up Procedures in Pharmaceutical Analysis

2012

Solid-phase extraction (SPE) using small cartridges filled with sorbents of a small particle size has rapidly established itself as an important sample clean-up technique. It has prospered at the expense of liquid-liquid extraction (LLE), which is considered labor intensive and frequently plagued by problems, such as emulsion formation and use of large volumes of hazardous solvents. A remarkable characteristic of SPE is its easy adaptation to on-line mode by column-switching techniques; switching can be effected manually or by automated controllers. The same analyte/sorbent interactions that are exploited in liquid chromatography (LC) are of use in SPE, but particle sizes employed are great…

CartridgeAnalytechemistry.chemical_compoundMaterials scienceSorbentChromatographychemistryExtraction (chemistry)Molecularly imprinted polymerSolid phase extractionDerivatizationClean-up
researchProduct

Flow Injection Fourier Transform Infrared Determination of Caffeine in Soft Drinks

1997

A fully automated procedure has been developed for FT-IR determination of caffeine in soft drinks. Samples are first degasified by filtration and then directly injected into a flow manifold and passed through a 100 mg C18 SPE cartridge, conditioned with methanol and water. After the cartridge has been cleaned with water, the caffeine is eluted with CHCl3 and stabilized with ethanol. The flow injection (FI) recording is obtained by measuring the absorbance at 1658 cm-1 with a baseline established at 1800 cm-1. Area values for the FI recording obtained between 0.4 and 1.4 min after sample injection are interpolated in the calibration graph of a series of aqueous standards of caffeine, which w…

ChromatographyChemistryCalibration curveElutionExtraction (chemistry)Analytical chemistryAnalytical Chemistrylaw.inventionAbsorbanceCartridgechemistry.chemical_compoundlawSolid phase extractionCaffeineFiltrationAnalytical Chemistry
researchProduct

Focused microwave-assisted Soxhlet extraction: An expeditive approach for the isolation of lipids from sausage products

2003

A prototype of extractor based on the conventional Soxhlet principles but assisted in the cartridge zone by focused microwaves is proposed for accelerating the extraction of lipids from sausage products. The extraction process has been optimised using a multivariate design involving the main variables influencing the performance of the prototype (namely, irradiation power P, irradiation time T and number of cycles C). Under the optimum working conditions (P=160 W, T=10 s and C=14), the extraction of lipids from different Spanish sausage products is complete in 45 min. The extracts thus obtained have been compared with those provided by conventional Soxhlet extraction for 8 h by development …

ChromatographyChemistryChromatographic analysisSize-exclusion chromatographyExtraction (chemistry)General MedicineIrradiation timePolar lipidsMicrowave assistedAnalytical ChemistryExtractorCartridgeMultivariate optimisationFocused microwavesSoxhlet extractionGas chromatographySausage productsFood ScienceFood Chemistry
researchProduct

Sample Preparation to Determine Pharmaceutical and Personal Care Products in an All-Water Matrix: Solid Phase Extraction

2020

© 2020 by the authors.

ConcentrationWater samplesPharmaceuticals and personal care productsPharmaceutical ScienceSewageReviewCosmeticsWastewater010501 environmental sciences01 natural sciencesEnvironmental impact of pharmaceuticals and personal care productsAnalytical ChemistryAigua AnàlisiTandem Mass SpectrometryDrug DiscoverySample preparationOnlineSolid phase extractionProcess engineeringGroundwaterChromatography High Pressure LiquidSewageDispersive liquid-liquid microextractionSolid Phase ExtractionDisksPharmaceutical PreparationsWastewaterChemistry (miscellaneous)Molecular MedicineEnvironmental MonitoringFarmacologiaLiquid Phase MicroextractionCartridgesSensitivity and SpecificityWater PurificationIsolationlcsh:QD241-441lcsh:Organic chemistryPhysical and Theoretical Chemistry0105 earth and related environmental sciencesSolid-phase extractionbusiness.industry010401 analytical chemistryOrganic ChemistryAnalytical techniqueExtraction (chemistry)Water0104 chemical sciencesEnvironmental sciencebusinessSurface waterWater Pollutants Chemical
researchProduct

Development and characterization of a thermal inkjet-based aerosol generator for micro-volume sample introduction in analytical atomic spectrometry

2011

A novel system for the introduction of liquid samples into analytical plasmas for atomic spectrometric analysis is presented in this manuscript for the first time. The proposed “drop-on-demand” (DOD) aerosol generator is based on the use of a modified thermal inkjet cartridge. This system employs a lab-built microcontroller, which allows accessing all parameters important for driving the dosing cartridge for the generation of pL-droplets from sample volumes in the μL range. The droplet generation frequency, thus the resulting liquid flow rate, is variable over a wide range from the generation of isolated droplets up to a theoretical flow rate of approximately 2 mL min−1, with parallel opera…

Detection limitCartridgeNebulizerChemistryAnalytical chemistryCalibrationFigure of meritAtomic spectroscopyStandard solutionSpectroscopyAnalytical ChemistryVolumetric flow rateJournal of Analytical Atomic Spectrometry
researchProduct

Study of passive sampling of polycyclic aromatic hydrocarbons in gas phase using Amberlite XAD resins as filling materials of semipermeable membranes

2013

Abstract In this work, a study was performed to evaluate the use of Amberlite XAD resins (XAD-2, XAD-4 and XAD-16), for the first time, as filling materials for low-density polyethylene membranes, which will be inserted as passive samplers for polycyclic aromatic hydrocarbons (PAHs) in gas phase. The use of samplers deployed for 48 h evidenced a relative capability to retain the compounds under study. A detailed study was performed to evaluate the recovery of analytes from the sampler through microwave-assisted extraction by using acetonitrile. A clean-up step using alumina-C18 cartridges was necessary before determination of the PAHs by high performance liquid chromatography with fluoresce…

Detection limitCartridgechemistry.chemical_compoundMembraneChromatographychemistryExtraction (chemistry)AmberlitePolyethyleneAcetonitrileHigh-performance liquid chromatographySpectroscopyAnalytical ChemistryMicrochemical Journal
researchProduct