Search results for "Chemical analysis."
showing 10 items of 308 documents
Determination of amphetamines in hair by integrating sample disruption, clean-up and solid phase derivatization
2016
The utility of matrix solid phase dispersion (MSPD) for the direct analysis of amphetamines in hair samples has been evaluated, using liquid chromatography (LC) with fluorescence detection and precolumn derivatization. The proposed approach is based on the employment of MSPD for matrix disruption and clean-up, followed by the derivatization of the analytes onto the dispersant-sample blend. The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. Different conditions for MSPD, analyte purification and solid phase derivatization have been tested, using amphetamine (AMP), methamphetamine (MET), ephedrine (EPE) and 3,4-methylenedioxymethamphetamine (MDMA)…
Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis
2010
Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…
Assessment of oxidative damage to proteins and DNA in urine of newborn infants by a validated UPLC-MS/MS approach
2014
The assessment of oxidative stress is highly relevant in clinical Perinatology as it is associated to adverse outcomes in newborn infants. This study summarizes results from the validation of an Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS) method for the simultaneous quantification of the urinary concentrations of a set of endogenous biomarkers, capable to provide a valid snapshot of the oxidative stress status applicable in human clinical trials, especially in the field of Perinatology. The set of analytes included are phenylalanine (Phe), para-tyrosine (p-Tyr), ortho-tyrosine (o-Tyr), meta-tyrosine (m-Tyr), 3-NO2-tyrosine (3NO(2)-Tyr), 3-Cl-tyrosine (3Cl-T…
The H-point and generalized H-point standard additions methods for flow injection procedures.
1997
This paper establishes the fundamentals of the H-point standard additions method (HPSAM) and generalized H-point standard additions method (GHPSAM) in the flow injection technique. Two kinds of analytical signals can be employed, FIA peaks and spectra. Different analytical problems have been studied: determinations of one analyte in the presence or absence of matrix effect when different blank features are present, and determination of two analytes in the presence of blank bias error affecting the development of one of them. The determination of chloride with mercury thiocyanate which presents a matrix effect, and the determinations of calcium and/or magnesium with arsenazo III are examined…
Immuno-SLM—a combined sample handling and analytical technique
2004
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…
Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry
2010
A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…
2006
Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …
Unveiling the oxidation behavior of liquid-phase exfoliated antimony nanosheets
2020
Abstract Antimonene, a monolayer of β-antimony, is increasingly attracting considerable attention, more than that of other monoelemental two-dimensional materials, due to its intriguing physical and chemical properties. Under ambient conditions, antimonene exhibits a high thermodynamic stability and good structural integrity. Some theoretical calculations predicted that antimonene would have a high oxidation tendency. However, it remains poorly investigated from the experimental point of view. In this work, we study the oxidation behavior of antimonene nanosheets (ANS) prepared by ultrasonication-assisted liquid-phase exfoliation. Using a set of forefront analytical techniques, a clear effe…
Association between COX-2 rs 6681231 genotype and interleukin-6 in periodontal connective tissue. A pilot study.
2014
[Objectives] The aim of this pilot study was to investigate associations between IL-6 and COX-2 expression in gingival biopsies and both clinical diagnosis and genotypes in the IL-6 and COX-2 genes. [Design] A case-control study included 41 gingival biopsies obtained from Caucasian patients grouped according to clinical diagnosis of gingival health (n = 10), gingivitis (n = 15) or chronic periodontitis (n = 16). Immunohistochemistry analyses were performed to determine COX-2 expression in lamina propria, IL-6 expression in lamina propria and gingival epithelium and level of inflammatory cell infiltrate. Individual DNA was extracted and genotyped by real-time PCR for IL6 SNPs rs 2069827 and …