Immuno-SLM—a combined sample handling and analytical technique
2004
Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted ac…
Cubic smoothing splines background correction in on-line liquid chromatography–Fourier transform infrared spectrometry
2010
A background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry (LC-FTIR) is proposed. The developed approach applies univariate background correction to each variable (i.e. each wave number) individually. Spectra measured in the region before and after each peak cluster are used as knots to model the variation of the eluent absorption intensity with time using cubic smoothing splines (CSS) functions. The new approach has been successfully tested on simulated as well as on real data sets obtained from injections of standard mixtures of polyethylene glycols with four different molecular weights in methanol:water, 2-propano…
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…
2006
Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …
Unveiling the oxidation behavior of liquid-phase exfoliated antimony nanosheets
2020
Abstract Antimonene, a monolayer of β-antimony, is increasingly attracting considerable attention, more than that of other monoelemental two-dimensional materials, due to its intriguing physical and chemical properties. Under ambient conditions, antimonene exhibits a high thermodynamic stability and good structural integrity. Some theoretical calculations predicted that antimonene would have a high oxidation tendency. However, it remains poorly investigated from the experimental point of view. In this work, we study the oxidation behavior of antimonene nanosheets (ANS) prepared by ultrasonication-assisted liquid-phase exfoliation. Using a set of forefront analytical techniques, a clear effe…
Association between COX-2 rs 6681231 genotype and interleukin-6 in periodontal connective tissue. A pilot study.
2014
[Objectives] The aim of this pilot study was to investigate associations between IL-6 and COX-2 expression in gingival biopsies and both clinical diagnosis and genotypes in the IL-6 and COX-2 genes. [Design] A case-control study included 41 gingival biopsies obtained from Caucasian patients grouped according to clinical diagnosis of gingival health (n = 10), gingivitis (n = 15) or chronic periodontitis (n = 16). Immunohistochemistry analyses were performed to determine COX-2 expression in lamina propria, IL-6 expression in lamina propria and gingival epithelium and level of inflammatory cell infiltrate. Individual DNA was extracted and genotyped by real-time PCR for IL6 SNPs rs 2069827 and …
Determination of phenytoin in plasma by molecularly imprinted solid-phase extraction.
2001
Abstract A molecularly imprinted polymer (MIP) using phenytoin as template and methacrylamide as the functional monomer was prepared. The selectivity was measured by comparing capacity factors of phenytoin and other structurally related compounds. The polymer was evaluated as a selective sorbent in molecularly imprinted solid-phase extraction (MISPE). Several washing solvents were tested to study their ability to disrupt the non-specific interactions occurring between the sample and the polymer matrix and the role of water in the recognition process was also investigated. It was shown that the key step of successful sample extraction is the right choice of the washing solvent. Plasma sample…
Smart materials for sample preparation in bioanalysis: A green overview
2021
Abstract The analysis of biological samples is a complex challenge due to the complexity of the matrix, but also to the low concentration of target analytes that must be determined. Consequently, different sample treatment procedures have been proposed in bioanalysis to clean-up and enrich sample extracts, paying special attention to microextraction approaches. In this frame, the combined use of microextraction approaches with smart materials provides environmentally friendly sample treatment strategies with improved selectivity, sensitivity, and reusability. Applications of smart solid materials includes antibody–antigen interaction based materials, aptamers, molecularly imprinted polymers…
A miniaturized method for estimating di(2-ethylhexyl) phthalate in bivalves as bioindicators.
2012
This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD), using C18 as dispersant and acetonitrile-water as eluting solvent, for the analysis of di(2-ethylhexyl) phthalate (DEHP) in biota samples by capillary liquid chromatography coupled to in-tube solid phase microextraction and diode array detection. Recovery studies showed that the combination of C18-Florisil® was optimal using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL 1:3.25, v/v). The sample is processed in less than 30 min, no evaporation step is required. The proposed method was applied to the analysis of DEHP in mussels and of the coastal waters in which they…
Towards the development of a fossil bone geochemical standard: An inter-laboratory study
2007
Ten international laboratories participated in an inter-laboratory comparison of a fossil bone composite with the objective of producing a matrix and structure-matched reference material for studies of the bio-mineralization of ancient fossil bone. We report the major and trace element compositions of the fossil bone composite, using in-situ method as well as various wet chemical digestion techniques. For major element concentrations, the intra-laboratory analytical precision (%RSDr) ranges from 7 to 18%, with higher percentages for Ti and K. The %RSDr are smaller than the inter-laboratory analytical precision (%RSDR; 100% was found for the high field strength elements (Hf, Th, Zr, Nb). The…