Search results for "Computer Vision"
showing 10 items of 2353 documents
RGB imaging system for mapping and monitoring of hemoglobin distribution in skin
2011
A prototype R-G-B imaging system for mapping of skin hemoglobin distribution has been designed and tested. Device basically consists of a commercial RGB sensor (CMOS, max. frame rate 87 fps for VGA resolution), RGB LED ringlight illuminator and orthogonally orientated polarizers for reducing specular reflectance. The system was examined for monitoring of hemoglobin concentration changes during specific provocations - arterial/venous occlusions and heat test. Hemoglobin distribution maps of several skin malformations were obtained, as well.
Computer vision profilometer: equipment and evaluation of measurements
1991
Abstract This paper describes a new equipment that measures roughness values by a computer vision (CV) technique. Measurements carried out by a CV profilometer are also evaluated. A laser source (power 2 mW), a cylindrical lens and a charge coupled device (CCD) TV-camera with a suitable optical system form an image of the profile of the sample under inspection. This image is then transformed into a binary image by thresholding and the line that divides the bright zone from the dark zone is the sample profile. From this line the characteristic roughness values can be calculated. The roughness measurements are carried out both by the CV profilometer and a stylus profilometer on eight specimen…
Transillumination imaging through biological tissue by single-pixel detection
2015
One challenge that has long held the attention of scientists is that of clearly seeing objects hidden by turbid media, as smoke, fog or biological tissue, which has major implications in fields such as remote sensing or early diagnosis of diseases. Here, we combine structured incoherent illumination and bucket detection for imaging an absorbing object completely embedded in a scattering medium. A sequence of low-intensity microstructured light patterns is launched onto the object, whose image is accurately reconstructed through the light fluctuations measured by a single-pixel detector. Our technique is noninvasive, does not require coherent sources, raster scanning nor time-gated detection…
Refractance window (RW) concentration of milk‐Part II: Computer vision approach for optimizing microbial and sensory qualities
2021
In Depth Flow Inspection based on Spatial Analysis of Dynamic Laser Speckle
2018
A novel optical approach based on statistical analysis of spatial laser speckle pattern for tissue in-depth flow characteristics is presented. Properties such as flow orientation and speed can be estimated. In-vitro experimental results are demonstrated.
Cover Feature: An Electrochemically Synthesized Nanoporous Copper Microsensor for Highly Sensitive and Selective Determination of Glyphosate (ChemEle…
2020
Modelling of Reflectance Spectra of Skin Phototypes III
2011
In dermatology, study of human skin colour is related to skin phototype (SPT) in which the Fitzpatrick's scale is the most used skin photo type classification. Assessment of skin response to UV for various reasons plays an important role in dermatology. This is however not easy to be performed because of two reasons. Firstly, skin areas may have different skin tone resulting in different reflectance spectra and secondly, different modalities may produce different reflectance spectra. We hypothesize that the underlying pattern of reflectance spectra must be similar regardless of the modalities use and the skin areas where it is obtained, for a particular person. An observational clinical stu…
A New Statistical Reconstruction Method for the Computed Tomography Using an X-Ray Tube with Flying Focal Spot
2021
Abstract This paper presents a new image reconstruction method for spiral cone- beam tomography scanners in which an X-ray tube with a flying focal spot is used. The method is based on principles related to the statistical model-based iterative reconstruction (MBIR) methodology. The proposed approach is a continuous-to-continuous data model approach, and the forward model is formulated as a shift-invariant system. This allows for avoiding a nutating reconstruction-based approach, e.g. the advanced single slice rebinning methodology (ASSR) that is usually applied in computed tomography (CT) scanners with X-ray tubes with a flying focal spot. In turn, the proposed approach allows for signific…
Experimental Characterization of the Human Meniscal Tissue
2018
The meniscus plays a critical role in load transmission, stability and energy dissipation in the knee joint. Loss of the meniscus leads to joint degeneration and osteoarthritis. In a number of cases replacement of the resected meniscal tissue by a synthetic implant might avoid the articular cartilage degeneration. None of the available implants presents optimal biomechanics characteristic due to the fact the biomechanics functionality of the meniscus is not yet fully understood. Mimicking the native biomechanical characteristics of the menisci seems to be the key factor in meniscus replacement functioning. This is extremely challenging due to its complex inhomogeneous microstructure, the la…
Communication: anion-specific response of mesoscopic organization in ionic liquids upon pressurization
2018
One of the outstanding features of ionic liquids is their inherently hierarchical structural organization at mesoscopic spatial scales. Recently experimental and computational studies showed the fading of this feature when pressurising. Here we use simulations to show that this effect is not general: appropriate anion choice leads to an obstinate resistance against pressurization. Published by AIP Publishing.