Search results for "DETECT"
showing 10 items of 5902 documents
Application of pressurized fluid extraction to determine cadmium and zinc in plants
2006
Abstract A procedure for the determination of Cd and Zn in plants is proposed. The metals are extracted by pressurized fluid extraction (PFE). Operational conditions are: pressure 1500 psi, temperature 75 °C, static time 5 min, flush volume 35%, purge time 60 s, cycles 1 and 1,2-diaminocyclohexane- N , N , N ′, N ′-tetraacetic acid (CDTA) 0.01 M at pH 4.5 as extracting solution. Determination of Zn is carried out by flame atomic absorption spectroscopy and depending on the concentration level, Cd content is determined by flame or electrothermal atomic absorption spectroscopy. Certified samples of Virginia tobacco leaves, tea leaves, spinach leaves, poplar leaves, a commercial spinach sample…
A New pH-Dependent Macrocyclic Rhodamine B-Based Fluorescent Probe for Copper Detection in White Wine
2019
For efficiently measuring copper (II) ions in the acidic media of white wine, a new chemosensor based on rhodamine B coupled to a tetraazamacrocyclic ring (13aneN4CH2NH2) was designed and synthesized by a one-pot reaction using ethanol as a green solvent. The obtained chemosensor was characterized via NMR, UV and fluorescent spectra. It was marked with no color emission under neutral pH conditions, with a pink color emission under acidic conditions, and a magenta color emission under acidic conditions where copper (II) ions were present. The sensitivity towards copper (II) ions was tested and verified over Ca2+, Ag+, Zn2+, Mg2+, Co2+, Ni2+, Fe2+, Pb2+, Cd2+, Fe3+, and Mn2+, with a detection…
Spatial distribution of temperature trends in Sicily
2014
The detection efficiency of the clover Ge-detectors array at the RITU-GREAT facility
2015
Absolute detection efficiency depending upon its position along the beam line is determined for three germanium detectors, that are part of the GREAT spectrometer at the RITU separator focal plane. The efficiency is determined for an energy range from 80 keV to 1400 keV for all three detectors as an array and also individually using digital electronics. The optimal position for the detector array has been defined for two configurations of the GREAT spectrometer: with planar detector and without it. The obtained results have been compared with three references: a simulation prepared especially for this setup by another student, a previous study that was carried out by applying analogue elect…
Upper limits on the isotropic gravitational-wave background from Advanced LIGO and Advanced Virgo's third observing run
2021
We report results of a search for an isotropic gravitational-wave background (GWB) using data from Advanced LIGO's and Advanced Virgo's third observing run (O3) combined with upper limits from the earlier O1 and O2 runs. Unlike in previous observing runs in the advanced detector era, we include Virgo in the search for the GWB. The results are consistent with uncorrelated noise, and therefore we place upper limits on the strength of the GWB. We find that the dimensionless energy density $\Omega_{\rm GW}\leq 5.8\times 10^{-9}$ at the 95% credible level for a flat (frequency-independent) GWB, using a prior which is uniform in the log of the strength of the GWB, with 99% of the sensitivity comi…
Stroke Cognitive Medical Assistant (StrokeCMA)
2018
Stroke is the number two killer after heart disease since it is responsible for almost 10% of all deaths worldwide. The main problem with a stroke is a significant delay in treatment that happened mainly due to inappropriate detection of stroke symptoms or inability of a person to perform further necessary actions, and might cause death, permanent disabilities, as well as more expensive treatment and rehabilitation. Nowadays assessment of a stroke is done by human, following widely adopted FAST approach of stroke assessment. Since a human factor become one of the causes of treatment delay, offered solution will try to minimize this factor. Artificial Intelligence, Cognitive Computing, Machi…
Solid-state-biased coherent detection of ultra-broadband terahertz pulses
2017
Significant progress in nonlinear and ultrafast optics has recently opened new and exciting opportunities for terahertz (THz) science and technology, which require the development of reliable THz sources, detectors, and supporting devices. In this work, we demonstrate the first solid-state technique for the coherent detection of ultra-broadband THz pulses (0.1-10 THz), relying on the electric-field-induced second-harmonic generation in a thin layer of ultraviolet fused silica. The proposed CMOS-compatible devices, which can be realized with standard microfabrication techniques, allow us to perform ultra-broadband detection with a high dynamic range by employing probe laser powers and bias v…
First Chemosensor for Selective Detection and Quantification of L-4-Hydroxyproline in Collagen and Other Bio Samples.
2017
Amino pyridine-based rhodamine conjugate (APR) has been developed as a first chemosensor for selective detection and quantification of L-4-Hydroxyproline (Hyp). The “turn-on” fluorescence property of the chemosensor makes it unique for easy estimation of Hyp in collagen and biological samples. peerReviewed
Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications
2009
Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector…
Protective coloration of European vipers throughout the predation sequence
2020
Antipredator adaptations in the form of animal coloration are common and often multifunctional. European vipers (genus Vipera) have a characteristic dorsal zigzag pattern, which has been shown to serve as a warning signal to potential predators. At the same time, it has been suggested to decrease detection risk, and to cause a motion dazzle or flicker-fusion effect during movement. We tested these hypotheses by asking whether (1) the zigzag pattern decreases detection risk and (2) the detection is dependent on the base coloration (grey or brown) or the snake's posture (coiled, basking form or S-shaped, active form). Additionally, (3) we measured the fleeing speed of adders, Vipera berus, an…