Search results for "DETECTOR"
showing 10 items of 3491 documents
Determination of alcohols in essential oils by liquid chromatography with ultraviolet detection after chromogenic derivatization
2013
Abstract An HPLC-UV method to determine compounds having a hydroxyl functional group in plant essential oils is developed. The sample is diluted with 1,4-dioxane and the analytes are derivatized with phthalic anhydride. The derivatives (phthalates hemiesters) are separated on a C8 column using an acetonitrile (ACN)/water gradient. Separation conditions were optimized using the DryLab® method development software. For the alcohols and phenols present in mint and rose essential oils, optimization led to a ca. 40 min gradient time and a column temperature of 8 °C. The alcohol and its derivatives were identified using HPLC with mass spectrometry (MS) detection. A large sensitivity enhancement w…
Search for neutral MSSM Higgs bosons at LEP
2006
The four LEP collaborations, ALEPH, DELPHI, L3 and OPAL, have searched for the neutral Higgs bosons which are predicted by the Minimal Supersymmetric Standard Model (MSSM). The data of the four collaborations are statistically combined and examined for their consistency with the background hypothesis and with a possible Higgs boson signal. The combined LEP data show no significant excess of events which would indicate the production of Higgs bosons. The search results are used to set upper bounds on the cross-sections of various Higgs-like event topologies. The results are interpreted within the MSSM in a number of "benchmark" models, including CP-conserving and CP-violating scenarios. Thes…
Studies of Quantum Chromodynamics with the ALEPH Detector
1998
Previously published and as vet unpublished QCD results obtained with the ALEPH detector at LEP1 are presented. The unprecedented statistics allows detailed studies of both perturbative and non-perturbative aspects of strong interactions to be carried out using hadronic Z and tau decays. The studies presented include precise determinations of the strong coupling constant. tests of its flavour independence, tests of the SU(3) gauge structure of QCD, study of coherence effects, and measurements of single-particle inclusive distributions and two-particle correlations for many identified baryons and mesons. (C) 1998 Elsevier Science B.V.
High-efficiency silicon-compatible photodetectors based on Ge quantum dots
2011
We report on high responsivity, broadband metal/insulator/semiconductor photodetectors with amorphous Ge quantum dots (a-Ge QDs) as the active absorbers embedded in a silicon dioxide matrix. Spectral responsivities between 1-4 A/W are achieved in the 500-900 nm wavelength range with internal quantum efficiencies (IQEs) as high as ∼700%. We investigate the role of a-Ge QDs in the photocurrent generation and explain the high IQE as a result of transport mechanisms via photoexcited QDs. These results suggest that a-Ge QDs are promising for high-performance integrated optoelectronic devices that are fully compatible with silicon technology in terms of fabrication and thermal budget. © 2011 Amer…
H-Point Curve Isolation Method for Coupled Liquid Chromatography and UV−Visible Spectrophotometry
2000
The H-point curve isolation method (HPCIM) for the detection of unknown interferences in chromatography is proposed. The method allows one to estimate the UV-vis spectra of interfering species in a sample as well as to test the purity of the chromatographic peaks. Besides the detection of the unknown interferences in a sample, this method allows one to calculate the concentration of an analyte in the presence of unknown compounds. To illustrate the reliability of the proposed method, samples of diuretics and amphetamines have been analyzed by normal- and reversed-phase high-performance chromatography.
SIGNAL PROCESSING ALGORITHM FOR SCHLIEREN EFFECT CORRECTION IN FLOW ANALYSIS
2001
Due to the radial refractive index gradients that sometimes develop in flow cells during the travelling of the samples through them, the absorbance records obtained in such conditions have a strange shape, particularly at low analyte levels. To correct this phenomenon, called Schlieren effect, a simple and reliable signal processing algorithm is described in correlation to the detector characteristics of noise. The algorithm is illustrated in nitrite and nitrate determinations with proflavin from more real samples. It has a solid theoretical support and involves the subtraction from the sample records of a smoothed signal, acquired by working with a blank solution.
Electrochemical pH Control at Gold Nanowires
2018
In this work, interdigitated arrays of nanowire electrodes are used with one array acting as the working electrode while the other is used to generate the required protons. Finite element simulations of the pH control electrodes were performed to provide insight on the generation and subsequent diffusion of protons. This informed the inter-tine spacing of the electrodes used.. This electrochemical pH control method was then used to enable the detection of analytes of interest.
A study of the effect of molecular and aerosol conditions in the atmosphere on air fluorescence measurements at the Pierre Auger Observatory
2010
The air fluorescence detector of the Pierre Auger Observatory is designed to perforin calorimetric measurements of extensive air showers created by Cosmic rays of above 10(18) eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group Of monitoring instruments to record atmospheric conditions across the detector site, ail area exceeding 3000 km(2). The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierr…
The IceCube prototype string in Amanda
2006
The Antarctic Muon And Neutrino Detector Array (Amanda) is a high-energy neutrino telescope. It is a lattice of optical modules (OM) installed in the clear ice below the South Pole Station. Each OM contains a photomultiplier tube (PMT) that detects photons of Cherenkov light generated in the ice by muons and electrons. IceCube is a cubic-kilometer-sized expansion of Amanda currently being built at the South Pole. In IceCube the PMT signals are digitized already in the optical modules and transmitted to the surface. A prototype string of 41 OMs equipped with this new all-digital technology was deployed in the Amanda array in the year 2000. In this paper we describe the technology and demonst…
Muon track reconstruction and data selection techniques in AMANDA
2004
The Antarctic Muon And Neutrino Detector Array (AMANDA) is a high-energy neutrino telescope operating at the geographic South Pole. It is a lattice of photo-multiplier tubes buried deep in the polar ice between 1500m and 2000m. The primary goal of this detector is to discover astrophysical sources of high energy neutrinos. A high-energy muon neutrino coming through the earth from the Northern Hemisphere can be identified by the secondary muon moving upward through the detector. The muon tracks are reconstructed with a maximum likelihood method. It models the arrival times and amplitudes of Cherenkov photons registered by the photo-multipliers. This paper describes the different methods of r…