Search results for "DEVICES"

showing 10 items of 615 documents

Nondeterministic Moore Automata and Brzozowski’s Algorithm

2011

Moore automata represent a model that has many applications. In this paper we define a notion of coherent nondeterministic Moore automaton (NMA) and show that such a model has the same computational power of the classical deterministic Moore automaton. We consider also the problem of constructing the minimal deterministic Moore automaton equivalent to a given NMA. In this paper we propose an algorithm that is a variant of Brzozowski's algorithm in the sense that it is essentially structured as reverse operation and subset construction performed twice.

Discrete mathematicsTheoryofComputation_COMPUTATIONBYABSTRACTDEVICESSettore INF/01 - InformaticaPowerset constructionBüchi automatonNonlinear Sciences::Cellular Automata and Lattice GasesNondeterministic algorithmTheoryofComputation_MATHEMATICALLOGICANDFORMALLANGUAGESDeterministic finite automatonDFA minimizationDeterministic automatonTwo-way deterministic finite automatonMoore automata minimization Brzozowski'algorithmNondeterministic finite automatonAlgorithmComputer Science::Formal Languages and Automata TheoryMathematics
researchProduct

On Extremal Cases of Hopcroft’s Algorithm

2009

In this paper we consider the problem of minimization of deterministic finite automata (DFA) with reference to Hopcroft’s algorithm. Hopcroft’s algorithm has several degrees of freedom, so there can exist different sequences of refinements of the set of the states that lead to the final partition. We find an infinite family of binary automata for which such a process is unique. Some recent papers (cf. [3,7,1]) have been devoted to find families of automata for which Hopcroft’s algorithm has its worst execution time. They are unary automata associated to circular words. However, automata minimization can be achieved also in linear time when the alphabet has only one letter (cf. [14]), so in …

Discrete mathematicsTheoryofComputation_COMPUTATIONBYABSTRACTDEVICESSettore INF/01 - InformaticaUnary operationBinary numberHopcroft's algorithmNonlinear Sciences::Cellular Automata and Lattice GasesAutomatonCombinatoricsSet (abstract data type)TheoryofComputation_MATHEMATICALLOGICANDFORMALLANGUAGESDeterministic finite automatonDFA minimizationMinificationAlgorithmTime complexityComputer Science::Formal Languages and Automata TheoryMathematics
researchProduct

Minimal nontrivial space complexity of probabilistic one- way turing machines

2005

Languages recognizable in o(log log n) space by probabilistic one — way Turing machines are proved to be regular. This solves an open problem in [4].

Discrete mathematicsTheoryofComputation_COMPUTATIONBYABSTRACTDEVICESSuper-recursive algorithmProbabilistic Turing machineLinear speedup theoremNSPACEDescription numberCombinatoricsTuring machinesymbols.namesakeTheoryofComputation_MATHEMATICALLOGICANDFORMALLANGUAGESNon-deterministic Turing machinesymbolsTime hierarchy theoremComputer Science::Formal Languages and Automata TheoryMathematics
researchProduct

Design of innovative friction damper devices for earthquake-resilient RC frames with Hybrid Steel-Trussed Concrete Beams

2021

This thesis focuses on the design of innovative friction damper devices for earthquake-resilient Reinforced Concrete (RC) frames realized with Hybrid Steel-Trussed Concrete Beams (HSTCBs). These devices fall within the framework of the recently-proposed low-damage design strategy for structures built in earthquake-prone areas, on the basis of which the structures are designed to experience negligible damage when subjected to seismic events. The comprehensive solution proposed aims at introducing a feasible option for building earthquake-resilient RC Moment Resisting Frames (MRFs), having been proposed very few solutions for this structural scheme so far. Innovative solutions are proposed fo…

Dissipative devicesSettore ICAR/09 - Tecnica Delle CostruzioniEarthquake-resilient structuresHybrid Steel-Trussed Concrete Beams
researchProduct

Therapeutic Drug Monitoring for Drugs Used in the Treatment of Substance-Related Disorders: Literature Review Using a Therapeutic Drug Monitoring App…

2011

Background The efficacy of drugs for the treatment of substance-related disorders is moderate at best. Therapeutic drug monitoring (TDM) could be an instrument to improve outcomes. Because TDM for most of those drugs is not established, the authors reviewed the literature and built a rating scale to detect the potential added value of TDM for these pharmacologic agents. Methods A literature search was performed for acamprosate, bupropion, buprenorphine, clomethiazole, disulfiram, methadone, naltrexone, and varenicline. The rating scale included 22 items and was divided in five categories: efficacy, toxicity, pharmacokinetics, patient characteristics, and cost-effectiveness. Three reference …

Drugmedicine.medical_specialtyNarcotic Antagonistsmedia_common.quotation_subjectchemistry.chemical_compoundmedicineHumansPharmacology (medical)Intensive care medicineVareniclinemedia_commonPharmacologyBupropionmedicine.diagnostic_testbusiness.industryTobacco Use Cessation DevicesAcamprosatechemistryTherapeutic drug monitoringDisulfiramDrug MonitoringbusinessAlcohol Deterrentsmedicine.drugMethadoneBuprenorphineTherapeutic Drug Monitoring
researchProduct

Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.

2013

BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…

Drugs and DevicesAnatomy and PhysiologyMaterials scienceSwinePartial PressurePhase (waves)Analytical chemistrychemistry.chemical_elementlcsh:Medicine610 Medicine & healthBioengineeringCardiovascularCardiovascular SystemOxygenFluorescence spectroscopyMedical Devices03 medical and health sciencesEngineering0302 clinical medicineAnesthesiologyDiagnostic MedicineAnimalsFluorometryddc:610030212 general & internal medicine610 Medicine & healthlcsh:ScienceBiologyBlood gas analysisPolarographyChemical PhysicsAnesthesiology TechnologyMultidisciplinaryPhysicslcsh:RPartial pressureModels TheoreticalOxygenChemistrychemistryElectrodeMedicineHigh temporal resolutionlcsh:QBlood Gas Analysis030217 neurology & neurosurgeryResearch ArticlePLoS ONE
researchProduct

Intracellular retention of ABL kinase inhibitors determines commitment to apoptosis in CML cells

2012

PLoS one 7(7), e40853 (2012). doi:10.1371/journal.pone.0040853

Drugs and DevicesDrug Research and DevelopmentTime Factorsmedicine.drug_classChronic Myeloid LeukemiaIntracellular Spacelcsh:MedicineApoptosisPharmacologyPiperazinesTyrosine-kinase inhibitorHematologic Cancers and Related DisordersCell Line TumorLeukemia Myelogenous Chronic BCR-ABL Positivehemic and lymphatic diseasesLeukemiasmedicineHumansAnnexin A5Proto-Oncogene Proteins c-abllcsh:ScienceProtein Kinase InhibitorsMyeloproliferative DisordersMultidisciplinaryABLDose-Response Relationship DrugCaspase 3Chemistrylcsh:RBiological activityImatinibHematologyrespiratory tract diseasesDasatinibKineticsPyrimidinesImatinib mesylatePharmacodynamicsBenzamidesImatinib MesylateMedicineATP-Binding Cassette Transporterslcsh:QDrug Screening Assays AntitumorSignal transductionIntracellularResearch ArticleSignal Transductionmedicine.drug
researchProduct

Validity and reliability of the DiCI for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects

2021

Background A higher risk of shoulder injury in the athletic and non-athletic population is frequently associated with strength deficits. Therefore, shoulder strength assessment can be clinically useful to identify and to quantify the magnitude of strength deficit. Thus, the aim of this study was to evaluate the validity and reliability of a DiCI (a new hand-held dynamometer) for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects. Methods Forty-three recreational athletes (29 males and 14 females; age: 22.1 ± 0.47 years; body mass: 68.7 ± 13.1 kg; height = 173.3 ± 9.7 cm) and 40 symptomatic subjects (28 males and 12 females; age: 49.9 ± 8.1 y…

Drugs and DevicesRelative reliabilitymedicine.medical_specialtyShoulderAnatomy and PhysiologyPopulationValidity/reliabilityValiditySymptomaticShoulder flexionAsymptomaticGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineRheumatologymedicineeducationShoulder injury030222 orthopedicseducation.field_of_studybiologyAthletesbusiness.industryGeneral NeuroscienceR030229 sport sciencesGeneral MedicineKinesiologybiology.organism_classificationHand-held dynamometerOrthopedicsStandard errorPhysical therapyMedicinemedicine.symptomGeneral Agricultural and Biological SciencesbusinessPeerJ
researchProduct

Optimal pareto solutions of a dynamic C chart: An application of statistical process control on a semiconductor devices manufacturing process

2015

The present paper proposes a novel economic-statistical design procedure of a dynamic c control chart for the Statistical Process Control (SPC) of the manufacturing process of semiconductor devices. Particularly, a non-linear constrained mathematical programming model is formulated and solved by means of the ε-constraint method. A numerical application is developed in order to describe the Pareto frontier, that is the set of optimal c charts and the related practical considerations are given. The obtained results highlight how the performance of the developed dynamic c chart overcome that of the related static one, thus demonstrating the effectiveness of the proposed procedure.

Dynamic C chartMultidisciplinaryStatistical process controlε-constraint methodMulti-objective designSemiconductor devices manufacturing
researchProduct

Monte Carlo simulation of high‐order harmonics generation in bulk semiconductors and submicron structures

2004

To qualify the feasibility of standard semiconductor materials and Schottky‐barrier diodes (SBDs) for THz high‐order harmonic generation and extraction, the harmonic intensity, intrinsic noise and signal‐to‐noise ratio are calculated by the Monte Carlo method when a periodic high‐frequency large‐amplitude external signal is applied to a semiconductor device. Due to very high signal‐to‐noise ratio heavily doped GaAs SBDs are found to exhibit conditions for frequency mixing and harmonic extraction that are definitively superior to those of bulk materials. (© 2004 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

EFFICIENCYDEVICESMaterials scienceINPMonte Carlo methodAnalytical chemistry02 engineering and technologySCHOTTKY-BARRIER DIODES01 natural sciencesNoise (electronics)NOISECondensed Matter::Materials Science0103 physical sciencesHigh harmonic generationTHZSILICONELECTRON-TRANSPORTDiode010302 applied physicsbusiness.industryGAASDopingSemiconductor device021001 nanoscience & nanotechnology[SPI.TRON]Engineering Sciences [physics]/ElectronicsHarmonicsHarmonicRADIATIONOptoelectronics0210 nano-technologybusinessphysica status solidi (c)
researchProduct