Search results for "Dental Abutment"

showing 10 items of 38 documents

The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study

2011

Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…

Dental Stress Analysisbone mechanical responseMaterials scienceimplant-abutment stresFinite Element AnalysisPlatform switchingDental Abutmentsimplant-abutment stressFinite element studyImaging Three-Dimensionalvon Mises yield criterionGeneral Dentistryplatform switchingDental Implant-Abutment Designfinite element analysis; implant-abutment stress; bone mechanical response; platform switching; implant-abutment stres:CIENCIAS MÉDICAS [UNESCO]Finite element methodBiomechanical PhenomenaStress fieldPlatform switching bone mechanical response finite element analysis implant-abutment stress.Dental Implant-Abutment DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantAbutment (dentistry)Biomedical engineering
researchProduct

Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation

2020

Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…

Dental Stress Analysisbusiness.product_categoryMaterials scienceScanning electron microscopemicrobial leakageDental AbutmentsFixtureFocused ion beamAbrasion (geology)law.inventionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE03 medical and health sciences0302 clinical medicineOpticslawfocused ion beam SEMMaterials TestingMicrotomeimplant-abutment connectionGeneral DentistryDental ImplantDental Implantsbusiness.industryResearchmorse taperDental Implant-Abutment Design030206 dentistryConical surface:CIENCIAS MÉDICAS [UNESCO]Machine toolCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASdental abutmentSurgerybusinessAbutment (dentistry)Implantology
researchProduct

Zirconia implant abutments: A review

2009

Objectives: An increasing aesthetic demand within developed populations conducted to the fabrication of metalfree restorations and to a wide use of ceramic materials, due to its excellent characteristics of biocompatibility and aesthetics. With the incessant increase of commercial labels involved in this technological advance, a review is imposed on ceramic abutments, specifically on zirconia. We made a search of articles of peer-reviewed Journals in PubMed/ Medline, crossing the terms ?Dental Abutments?, ?Dental Porcelain? and ?Zirconia?. The review was divided by subtopics: zirconia physical and mechanical properties, precision fit in the implant-abutment interface, zirconia abutments str…

Engineeringbusiness.industryProve itDentistryDental Abutments:CIENCIAS MÉDICAS [UNESCO]Ceramic abutmentsDental MaterialsDental porcelainDental Prosthesis DesignOtorhinolaryngologyDental AbutmentsUNESCO::CIENCIAS MÉDICASDental Prosthesis DesignHumansSurgeryCubic zirconiaZirconiumImplantTechnological advancebusinessGeneral DentistryMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Comparison of peri-implant soft tissues in submerged versus transmucosal healing: A split mouth prospective immunohistochemical study

2018

Objective The present split-mouth prospective study involves an immunohistochemical evaluation of peri-implant soft tissue healing after the osseointegration period, comparing submerged and transmucosal approaches using two-piece implant systems. The null hypothesis was that both surgical procedures elicit a similar immune response of the peri-implant soft tissues. Design Thirty-one healthy patients were included in this study, in which two implants were placed in the right and left maxillary pre-molar regions. A total of 62 dental implants were analyzed, establishing a control side with 31 submerged implants, and a study side with 31 exposed implants bearing healing abutments. After a thre…

Male0301 basic medicineTecnología de materialesBiopsymedicine.medical_treatmentDentistryDental AbutmentsOdontologíaOsseointegration03 medical and health sciencesDental Implants Single-Tooth0302 clinical medicineImmune systemOsseointegrationBiopsyMaxillaHumansMedicineLymphocytesProspective StudiesIL-2 receptorDental implantTecnología médicaGeneral DentistryDental ImplantsWound Healingmedicine.diagnostic_testbusiness.industryDental Implantation EndosseousMouth MucosaSoft tissue030206 dentistryCell BiologyGeneral MedicineMiddle AgedImplantación dentalImmunohistochemistry030104 developmental biologyOtorhinolaryngologySpainFemaleDental Prosthesis Implant-SupportedImplantbusinessWound healing
researchProduct

Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.

2014

Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…

MaleDentistryEikenella corrodensDental AbutmentsClinical study; Implant connection; Implant-abutment microgap; Microbial leakageClinical studyImplant-abutment microgapHumansAgedDental Implantsbiologybusiness.industryAggregatibacter actinomycetemcomitansPrevotella intermediaCampylobacter rectusTreponema denticolaDental Implant-Abutment DesignGingival Crevicular Fluidbiology.organism_classificationRed complexCross-Sectional StudiesTreatment OutcomeImplant connectionFemaleImplantMicrobial leakageDental Prosthesis Implant-SupportedOral SurgeryFusobacterium nucleatumbusinessClinical oral implants research
researchProduct

Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial

2016

The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with …

MaleGenetics and Molecular Biology (all)Pathologymedicine.medical_specialtyPlasma GasesArticle SubjectCleaning methodsImmunology and Microbiology (all)Statistical differencelcsh:MedicineDental AbutmentsBiochemistryGeneral Biochemistry Genetics and Molecular BiologySoft Tissue Responselaw.inventionPlasma Gase03 medical and health sciences0302 clinical medicineRandomized controlled trialDental AbutmentslawCollagen; Female; Humans; Male; Middle Aged; Mouth; Plasma Gases; Titanium; Wound Healing; Dental AbutmentsHumansMedicineddc:610TitaniumMouthWound HealingDental AbutmentBiochemistry Genetics and Molecular Biology (all)General Immunology and Microbiologybusiness.industrySignificant differencelcsh:RSoft tissue030206 dentistryGeneral MedicineMiddle AgedClinical StudyFemaleCollagenWound healingbusinessHuman030215 immunologyBiochemistry; Genetics and Molecular Biology (all); Immunology and Microbiology (all)BioMed Research International
researchProduct

Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…

2016

Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…

MaleRandomizationimplantRadiographyPlatform switchingAlveolar Bone LossDentistryDental AbutmentsMandiblelaw.inventioncrestal bone preservation03 medical and health sciences0302 clinical medicineRandomized controlled trialDental AbutmentslawMedicineHumansstandardized radiographDental ImplantsCrestal boneCrownsbusiness.industryplatform switchingDental Implantation EndosseousMandiblebone level030206 dentistryMiddle AgedDental Prosthesis Designimplant success030220 oncology & carcinogenesisRandomized Clinical Trialplatform matchPeriodonticsFemaleImplantbusinessImplant TherapyFollow-Up StudiesJournal of clinical periodontology
researchProduct

Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…

2019

Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…

Malemedicine.medical_treatmentAlveolar Bone LossDentistryDental AbutmentsMandibleProsthesisOsseointegrationlaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawOsseointegrationMaxillaMedicineHumansProspective StudiesGeneral DentistryAgedDental Implantsbusiness.industryResearchDental prosthesisDental Implantation EndosseousResonance Frequency Analysis030206 dentistryMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Implant-Abutment DesignOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryFemaleImplantDental Prosthesis Implant-SupportedOral SurgerybusinessMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases

2010

Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…

Malemedicine.medical_treatmentDentistryBiocompatible MaterialsDental AbutmentsEsthetics DentalDental Materialsstomatognathic systemDental AbutmentsDental Prosthesis DesignHumansJaw EdentulousMedicineCubic zirconiaPeriodontal DiseasesAgedRetrospective StudiesDental ImplantsOrthodonticsCrownsbusiness.industryDental prosthesisDenture Complete UpperElectrochemical TechniquesDental Marginal AdaptationMiddle AgedDenture OverlayDenture RetentionDental Marginal Adaptationstomatognathic diseasesDental Prosthesis DesignMaxillaComputer-Aided DesignGold AlloysFemaleDental Prosthesis Implant-SupportedZirconiumImplantOral SurgeryDenturesbusinessFollow-Up StudiesJournal of Oral Implantology
researchProduct

A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.

2009

Background: There is a lack of clinical studies on the self-aligning attachment system (Locator®; Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. MaterialsandMethods: From 2003 to 2007, 60 patients received two Osseotite® TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded throug…

Malemedicine.medical_treatmentDenture Complete LowerDentistryDental AbutmentsOral HealthMandiblelaw.inventionDental AbutmentsRandomized controlled triallawmedicineDenture Precision AttachmentHumansJaw EdentulousProspective StudiesDental implantProspective cohort studyDenture DesignGeneral DentistryDenture RetentionAgedOrthodonticsAged 80 and overDental Implantsbusiness.industryDental prosthesisDental Implantation EndosseousMiddle AgedDenture OverlayDenture RetentionTreatment OutcomeDenture DesignQuality of LifeFemaleImplantDental Prosthesis Implant-SupportedOral SurgerybusinessClinical implant dentistry and related research
researchProduct