Search results for "Dental Abutment"
showing 10 items of 38 documents
The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
2011
Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…
Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation
2020
Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…
Zirconia implant abutments: A review
2009
Objectives: An increasing aesthetic demand within developed populations conducted to the fabrication of metalfree restorations and to a wide use of ceramic materials, due to its excellent characteristics of biocompatibility and aesthetics. With the incessant increase of commercial labels involved in this technological advance, a review is imposed on ceramic abutments, specifically on zirconia. We made a search of articles of peer-reviewed Journals in PubMed/ Medline, crossing the terms ?Dental Abutments?, ?Dental Porcelain? and ?Zirconia?. The review was divided by subtopics: zirconia physical and mechanical properties, precision fit in the implant-abutment interface, zirconia abutments str…
Comparison of peri-implant soft tissues in submerged versus transmucosal healing: A split mouth prospective immunohistochemical study
2018
Objective The present split-mouth prospective study involves an immunohistochemical evaluation of peri-implant soft tissue healing after the osseointegration period, comparing submerged and transmucosal approaches using two-piece implant systems. The null hypothesis was that both surgical procedures elicit a similar immune response of the peri-implant soft tissues. Design Thirty-one healthy patients were included in this study, in which two implants were placed in the right and left maxillary pre-molar regions. A total of 62 dental implants were analyzed, establishing a control side with 31 submerged implants, and a study side with 31 exposed implants bearing healing abutments. After a thre…
Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.
2014
Objective To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. Materials and methods A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (…
Soft Tissue Response to Titanium Abutments with Different Surface Treatment: Preliminary Histologic Report of a Randomized Controlled Trial
2016
The aim of this preliminary prospective RCT was to histologically evaluate peri-implant soft tissues around titanium abutments treated using different cleaning methods. Sixteen patients were randomized into three groups: laboratory customized abutments underwent Plasma of Argon treatment (Plasma Group), laboratory customized abutments underwent cleaning by steam (Steam Group), and abutments were used as they came from industry (Control Group). Seven days after the second surgery, soft tissues around abutments were harvested. Samples were histologically analyzed. Soft tissues surrounding Plasma Group abutments predominantly showed diffuse chronic infiltrate, almost no acute infiltrate, with …
Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…
2016
Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.
2009
Background: There is a lack of clinical studies on the self-aligning attachment system (Locator®; Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. MaterialsandMethods: From 2003 to 2007, 60 patients received two Osseotite® TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded throug…