Search results for "Detector"
showing 10 items of 3491 documents
Search for Isovector Valence-Shell Excitations in 140 Nd and 142 Sm via Coulomb excitation reactions of radioactive ion beams
2018
Projectile Coulomb excitation experiments were performed at HIE-ISOLDE at CERN with the radioactive ion beams of 140Nd and 142Sm. Ions with an energy of 4:62 MeV/A were impinging on a 1.45 mg/cm2 thick 208Pb target. The γ-rays depopulating the Coulomb-excited states were recorded by the HPGe-array MINIBALL and scattered particles were detected by a double-sided silicon strip detector. Experimental intensities were used for the determination of electromagnetic transition matrix elements. A preliminary result of the B(M1; 2+3 → 2+1) of 140Nd and an upper limit for the case of 142Sm are revealing the main fragments of the proton-neutron mixed-symmetry 2+1;ms states.
The Cryogenic AntiCoincidence detector for ATHENA: the progress towards the final pixel design
2014
“The Hot and Energetic Universe” is the scientific theme approved by the ESA SPC for a Large mission to be flown in the next ESA slot (2028th) timeframe. ATHENA is a space mission proposal tailored on this scientific theme. It will be the first X-ray mission able to perform the so-called “Integral field spectroscopy”, by coupling a high-resolution spectrometer, the X-ray Integral Field Unit (X-IFU), to a high performance optics so providing detailed images of its field of view (5’ in diameter) with an angular resolution of 5” and fine energy-spectra (2.5eV@E<7keV). The X-IFU is a kilo-pixel array based on TES (Transition Edge Sensor) microcalorimeters providing high resolution spectroscopy …
Solar Surface Magnetism and Irradiance on Time Scales from Days to the 11-Year Cycle
2009
The uninterrupted measurement of the total solar irradiance during the last three solar cycles and an increasing amount of solar spectral irradiance measurements as well as solar imaging observations (magnetograms and photometric data) have stimulated the development of models attributing irradiance variations to solar surface magnetism. Here we review the current status of solar irradiance measurements and modelling efforts based on solar photospheric magnetic fields. Thereby we restrict ourselves to the study of solar variations from days to the solar cycle. Phenomenological models of the solar atmosphere in combination with imaging observations of solar electromagnetic radiation and meas…
Application of matrix solid-phase dispersion to the determination of a new generation of fungicides in fruits and vegetables.
2002
A method based on matrix solid-phase dispersion (MSPD) and gas chromatography to determine eight fungicides in fruits and vegetables is described. Fungicide residues were identified and quantified using nitrogen-phosphorus detection and electron-capture detection connected in parallel and confirmed by mass spectrometric detection. The method required 0.5 g of sample, C18 bonded silica as dispersant sorbent, silica as clean-up sorbent and ethyl acetate as eluting solvent. Recoveries from spiked orange, apple, tomato, artichoke, carrot and courgette samples ranged from 62 to 102% and relative standard deviations were less than 15% in the concentration range 0.05-10 mg kg(-1). Detection and qu…
Microphones’ Directivity for the Localization of Sound Sources
2011
In a recent paper [P. Rizzo, G. Bordoni, A. Marzani, and J. Vipperman, "Localization of Sound Sources by Means of Unidirectional Microphones, Meas. Sci. Tech., 20, 055202 (12pp), 2009] the proof-of-concept of an approach for the localization of acoustic sources was presented. The method relies on the use of unidirectional microphones and amplitude-based signals' features to extract information about the direction of the incoming sound. By intersecting the directions identified by a pair of microphones, the position of the emitting source can be identified. In this paper we expand the work presented previously by assessing the effectiveness of the approach for the localization of an acoustic…
Advanced functionality for radio analysis in the Offline software framework of the Pierre Auger Observatory
2011
The advent of the Auger Engineering Radio Array (AERA) necessitates the development of a powerful framework for the analysis of radio measurements of cosmic ray air showers. As AERA performs ‘‘radio- hybrid’’ measurements of air shower radio emission in coincidence with the surface particle detectors and fluorescence telescopes of the Pierre Auger Observatory, the radio analysis functionality had to be incorporated in the existing hybrid analysis solutions for fluorescence and surface detector data. This goal has been achieved in a natural way by extending the existing Auger Offline software framework with radio functionality. In this article, we lay out the design, highlights and features …
A hybrid method for calorimetry with subnanoliter samples using Schottky junctions
2007
A μm-scale calorimeter realized by using Schottky junctions as a thermometer is presented. Combined with a hybrid experimental method, it enables simultaneous time-resolved measurements of variations in both the energy and the heat capacity of subnanoliter samples.
Potential application of some wide band gap materials for UV dosimetry
2005
Properties of some wide band gap materials–natural and CVD diamonds – have been studied for their potential application in UV dosimetry, using methods of optically stimulated luminescence and thermoluminescence. The observed properties are compared with those of the previously studied AlN ceramics. From the OSL excitation spectra, it follows that spectral sensitivity of the studied materials falls mainly into the UVC range, OSL and TL emission spectra are located within the visible light region, thus suitable for usual photodetectors. OSL stimulation spectra of the studied materials have a continuous character and are located in a broad visible/near infrared spectral region implying that th…
Chromatographic Air Analyzer Microsystem for the Selective and Sensitive Detection of Explosive-related Compounds
2014
Abstract The detection of explosives and explosive-related compounds is of major importance for the monitoring of explosive- contaminated sites. Current methods need to become cheaper and portable while maintaining a high sensitivity and selectivity level. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level in the presence of toluene and moisture.
Design of a real-time spectroscopic rotating compensator ellipsometer without systematic errors
2014
6th International Conference on Spectroscopic Ellipsometry (ICSE), Kyoto, JAPAN, MAY 26-31, 2013; International audience; We describe a spectroscopic ellipsometer in the visible domain (400-800 nm) based on a rotating compensator technology using two detectors. The classical analyzer is replaced by a fixed Rochon birefringent beamsplitter which splits the incidence light wave into two perpendicularly polarized waves, one oriented at +45 degrees and the other one at-45 degrees according to the plane of incidence. Both emergent optical signals are analyzed by two identical CCD detectors which are synchronized by an optical encoder fixed on the shaft of the step-by-step motor of the compensato…