Search results for "ELECTROSURGERY"
showing 10 items of 17 documents
Imaging findings of liver resection using a bipolar radiofrequency electrosurgical device—Initial observations
2010
Abstract Objective To assess contrast-enhanced US (CEUS), computed tomography (CT) and magnetic resonance (MR) imaging findings and serial changes of the treated area at follow-up in patients who underwent liver resection using a bipolar radiofrequency electrosurgical device. Methods Imaging findings of 27 patients with resected hepatocellular carcinomas (HCCs) ( n = 24) and metastases ( n = 3) (mean size: 2.6 cm), were retrospectively evaluated. Two readers assessed: the (a) presence, (b) thickness, (c) shape and (d) echogenicity (CEUS)/attenuation (CT)/signal intensity (MR imaging) at coagulated site and the (e) presence of residual tumor of the bipolar radiofrequency electrosurgical de…
A histological evaluation of the surgical margins from human oral fibrous-epithelial lesions excised with CO2 laser, Diode laser, Er:YAG laser, Nd:YA…
2018
Background We aim to evaluate the presence of histological artefacts in the surgical margins of human oral fibro-epithelial hyperplasias excised with lasers of different wavelengths, and also electrosurgical scalpel and cold scalpel. Moreover, we aim to determine if some of these instruments could impair the normal histological diagnosis of these lesions. Material and Methods We included 130 consecutive surgical samples of 80 females and 50 males (mean age of 53.82±16.55) with a histological diagnosis of an oral benign fibrous-epithelial hyperplasias. The samples were categorized into 6 groups according to the type of instrument used: CO2 laser group, diode laser group, Er:YAG laser group, …
Piezosurgery in endoscopic dacryocystorhinostomy
2009
Piezosurgery is a recently developed system for cutting bone with microvibrations. The equipment consists of two hand pieces, two inserts, and two peristaltic pumps connected to the control unit. The device is endowed with an irrigation system of high-flow saline solution that breaks up into very small particles, with a “bloodless” effect on the surgical site and a low indirect thermal damage to the bone surfaces and adjacent structures. 4,5 The touch screen of the main unit permits selection of the specific insert, and modulation of the irrigation and the power according to the bone density. The device uses low-frequency ultrasonic waves (24.7-29.5 kHz), the applied power can be modulated …
A multicentric randomized study comparing two techniques of magnification assisted loop excision of high-grade cervical intraepithelial neoplasia: vi…
2013
Purpose: To compare loop excisions of cervical intraepithelial neoplasia grade 2 or worse (CIN 2+) under video exoscopy, or colposcopic guidance, with respect to safety and effectiveness. Methods: Prospective multicentric randomized trial of 300 patients, undergoing loop excision for CIN 2+ either under video exoscopy (group A) or colposcope (group B) guidance. Intra- and post-operative complications, resection margins, and removed cervical volume in both groups were evaluated. Results: 19.3% of patients in video exoscopy group and 15.5% in colposcopy group (p = 0.67) had transformation zone (TZ) 3. 45/151 (29.8%) of group A patients and 48/149 (32.2%) of group B patients underwent top-hat …
Small-diameter hysteroscopy with Versapoint versus resectoscopy with a unipolar knife for the treatment of septate uterus: A prospective randomized s…
2007
Abstract Study objective To compare 2 procedures for metroplasty: resectoscopy with monopolar knife versus small-diameter hysteroscopy fitted with a Versapoint device. Design Prospective randomized study (Canadian Task Force classification I). Setting Endoscopic gynecology units at tertiary care university hospitals. Patients One hundred-sixty patients with septate uterus and a history of recurrent abortion or primary infertility undergoing hysteroscopic metroplasty from 2001 to 2005. Interventions Hysteroscopic resection of the uterine septum performed with either a 26F resectoscope with unipolar knife (80 women, group A) or a 5-mm diameter hysteroscope with Versapoint device (80 women, gr…
Benefits of Direct Colposcopic Vision for Optimal LLETZ Procedure: A Prospective Multicenter Study.
2015
International audience; Objective The aim of the study was to assess whether direct colposcopic ă vision (DCV) of the cervix during large loop excision of the ă transformation zone (LLETZ) is associated with a decrease in the volume ă and dimensions of specimens or affects margin status at histology. ă Materials and Methods A prospective multicenter observational study of ă 216 women who underwent LLETZ for grades 2 and 3 cervical ă intraepithelial neoplasia was conducted. The volume and dimensions ă (circumference, length, and thickness) of the surgical specimens were ă measured before fixation. Data were compared according to the use of ă colposcopy during LLETZ. The following 3 groups we…
Tiroidectomia totale con impiego del dissettore ad ultrasuoni: risultati di uno studio prospettico randomizzato
2005
In the last years, the introduction and employment in surgery of the dissectors of last generation (ultrasounds, radiofrequency, etc.) have contributed to a remarkable improvement and simplification of the performances and the surgical techniques. The present study has the aim to verify, on the basis of the experience made in the last two years and through a careful comparisons with operations performed in the usual way, the advantages of employment of ultrasonic dissector in thyroid surgery and if besides such advantages it is possible to obtain real and substantial reductions of the complications. To such aim a randomized perspective study has been lead, confronting two groups of 60 patie…
Koblācija un radiofrekvences ķirurģija otolaringoloģijā. Literatūras apskats un salīdzinoši eksperimenti in vitro
2016
Radiofrekvences un radiofrekvences koblācijas metodes aizvien vairāk tiek pielietotas kā rīkles, tā deguna gliemežnīcu ķirurģijā, tomēr dati par šo procedūru laikā sasniegtajām temperatūrām audos ir skopi. Eksperimentālā pētījuma pirmajā daļā in vitro tika iegūti dati par sasniegtajām temperatūrām koblācijas laikā, kā arī veikta paraugu, ņemtu instrumenta pieskaršanās zonā, histoloģiskā analīze. Cūkas muskuļaudos tika sasniegta 370°C, kamēr submandibulārā dziedzera audos – 320°C temperatūra. Eksperimentālā pētījuma otrajā daļā cūkas deguna gliemežnīcās koblācija tika salīdzināta ar divām citām bipolārām radiofrekvences metodēm, tika iegūti dati par sasniegtajām temperatūrām šo metožu pielie…
Percutaneous antegrade electropapillotomy. Study in dogs.
1984
Antegrade electropapillotomy using the percutaneous transcystic approach was successfully performed in 11 of 16 dogs. When the intervention was effective, the pressure gradient between common bile duct and duodenum decreased from 6 to 1.3 mm Hg on average and returned to gradients slightly below the initial values after 4 weeks, owing to reactivation of the sphincter mechanism. Ineffective cutting, however, resulted in a temporary pressure rise. In one dog a papillary stenosis developed and was relieved by antegrade electrocutting. Irrespective of the success of the papillotomy, rises in levels of serum glutamine oxaloacetic and pyruvic transaminase, alkaline phosphatase, serum amylase and …
Total Thyroidectomy Performed With the Starion Vessel Sealing System Versus the Conventional Technique: A Prospective Randomized Trial
2010
Meticulous dissection and accurate hemostasis are required in thyroid surgery. The authors recently performed a number of thyroidectomies using a new device that combines heat and pressure for sealing and cutting tissue. A prospective randomized trial was conducted on 98 patients subjected to total thyroidectomy for benign disease: 49 patients (group A) with the Starion tissue welding system and 49 (group B) with the clamp-and-tie technique. The 2 groups were comparable in mean age, gender, thyroidal volume (20-60 mL), incision length (<35 mm), and pathology. The authors evaluated operative time, postoperative serum calcemia, dosage and length of postoperative calcium and vitamin D trea…