Search results for "ESOL"
showing 10 items of 2444 documents
Evaluation of several global resolution functions for liquid chromatography
1999
Abstract An interpretative approach, that makes use of the overlapped fraction of each chromatographic peak as elementary resolution criterion, was applied to the separation of mixtures of compounds. The elementary resolution measurements for all peaks in the chromatogram were reduced to a single numerical value using several functions: normalised by the mean resolution product, unnormalised product, geometrical mean of the unnormalised product, and worst elementary resolution value. The descriptive capability of these reduction functions was evaluated through the observation of global resolution diagrams and the change in the shape of the chromatograms in the selected factor space. michrom…
Resolution of inherently chiral resorcarene derivatives by enantioselective HPLC
1999
Abstract The HPLC enantiomeric resolution of five inherently chiral tetrabenzoxazine derivatives of resorcarenes has been achieved by HPLC using Whelk-Ol and in one case Chiralpak AD as stationary phases. Enantiomeric separation was only observed in a very narrow range of mobile phase compositions. On-column enantiomeric interconversion of a racemic compound with a typical plateau-like elution profile was observed using a Chiralpak AD column
Reversed-phase high-performance liquid chromatography of proteins and polypeptides on polystyrene-coated silica supports
1990
Abstract A new type of hydrolytically stable reversed-phase packing material prepared by multi-point covalent binding of polystyrene chains onto the surface of porous silica was examined in the high-performance liquid chromatography of proteins and polypeptides. Whereas wide-pore material was shown to give a rapid and efficient resolution of proteins, packings with smaller pores provided better selectivities for peptides.
Separation of U(VI) and Th(IV) from Some Rare Earths by Thin Layer Chromatography with Di‐(2‐Ethylhexyl)‐Dithiophosphoric Acid on Silica Gel
2005
Abstract Separation of U(VI) and Th(IV) from some rare earths by TLC has been studied using silica gel H and silica gel H impregnated with ammonium nitrate as the stationary phase. The solvent mixture ethyl‐methyl‐ketone–tetrahydrofuran (6∶3, v/v) containing di-(2‐ethylhexyl)-dithiophosphoric acid was used as the mobile phase. When silica gel H impregnated with 2.5 M NH4NO3 was used as stationary phase, the resolution was much improved and the separation of rare earths from each other was also achieved. The tetrad‐effect was observed in variation of R*m versus the atomic number of rare earths.
Methods for the rapid detection, isolation and sequence determination of “peptaibols” and other aib-containing peptides of fungal origin. I. Gliodeli…
1984
A rapid and simple detection procedure of Aib-containing “peptaibol” polypeptide antibiotics (mycotoxins) in fungal culture broths is described which employs alkylsilica (Sep-Pak®) cartridges for a selective enrichment, and the utilization of the unusualα-aminoisobutyric acid (Aib) and amino alcohols as specific marker constituents, which are easily detectable in total hydrolysates. Preparative isolations from fermentation broths is facilitated by adsorber resin (XAD) column chromatography, and purification of crude isolates is achieved by silica gel- and sephadex LH-20 chromatography. Preparative HPLC using spherical, totally porous ODS-bonded phases enables the isolation of uniform peptid…
Fast enantiomeric separation of propranolol by affinity capillary electrophoresis using human serum albumin as chiral selector: application to qualit…
2004
Abstract In the last years, capillary electrophoresis (CE) has gained considerable interest in pharmaceutical laboratories for controlling the chiral purity of drugs. This paper describes a simple and fast method for resolution of propranolol enantiomers by affinity capillary electrophoresis (ACE) using human serum albumin (HSA) as chiral selector. The effect of several experimental variables such as HSA concentration, temperature, chiral selector plug length and addition of organic modifiers, on the separation is evaluated. Complete enantioresolution of R- and S-propranolol was achieved in less than 5 min when the capillary was completely filled with 100 μM HSA solution and the electrophor…
Assessment and optimization of system parameters in size exclusion separation of proteins on diol-modified silica columns
1981
Abstract On diol-modified silica columns the retention of proteins is governed by a size exclusion effect, but superimposed on this are some secondary effects, i.e. , ionic and diol-ligand interactions which can be controlled and adjusted reproducibly by varying the eluent composition. The eluent composition also affects the column efficiency and peak shape. Both dependences can be employed to obtain a better resolution of proteins than can be expected from size exclusion alone.
Program for the interpretive optimization of two-dimensional resolution.
2016
The challenge of fully optimizing LC × LC separations is horrendous. Yet, it is essential to address this challenge if sophisticated LC × LC instruments are to be utilized to their full potential in an efficient manner. Currently, lengthy method development is a major obstacle to the proliferation of the technique, especially in industry. A program was developed for the rigorous optimization of LC × LC separations, using gradient-elution in both dimensions. The program establishes two linear retention models (one for each dimension) based on just two LC × LC experiments. It predicts LC × LC chromatograms using a simple van-Deemter model to generalize band-broadening. Various objectives (ana…
Enantioseparation of phenotiazines by affinity electrokinetic chromatography using human serum albumin as chiral selector
2007
Nowadays, there is a special interest within the pharmaceutical laboratories to develop single enantiomer formulations and consequently a need for analytical methods to determine the enantiomeric purity of drugs. The present paper deals with the enantiomeric separation of promethazine and trimeprazine enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization of the most critical experimental variables in enantioresolution, running pH, HSA concentration and plug length, is carried out to obtain enantioresolution of promethazine and trimeprazine. The estimated maximum and optimum resol…
Enantiomeric separation of chiral phenoxy acid herbicides by electrokinetic chromatography. Application to the determination of analyte-selector appa…
2001
The enantiomeric resolution of chiral phenoxy acid herbicides was performed by electrokinetic chromatography using a cyclodextrin as chiral pseudophase (CD-EKC). A systematic evaluation of several neutral and charged cyclodextrins was made. Among the cyclodextrins tested, (2-hydroxy)propyl beta-cyclodextrin (HP-beta-CD) was found to be the most appropriate for the enantioseparation of phenoxy acids. The influence of some experimental conditions, such as nature and pH of the background electrolyte, chiral selector concentration, and temperature, on the enantiomeric separation of phenoxy acids was also studied. The use of a 50 mM electrolyte solution in ammonium formate at pH 5 and a temperat…