Search results for "Enhancement."
showing 10 items of 557 documents
Polarized multiplex coherent anti-Stokes Raman scattering using a picosecond laser and a fiber supercontinuum
2011
International audience; We perform multiplex coherent anti-Stokes Raman scattering (CARS) micro-spectroscopy with a picosecond pulsed laser and a broadband supercontinuum (SC) generated in photonic crystal fiber. CARS signal stability is achieved using an active fiber coupler that avoids thermal and mechanical drifts. We obtain multiplex CARS spectra for test liquids in the 600–2000 cm−1 spectral range. In addition we investigate the polarization dependence of the CARS spectra when rotating the pump beam linear polarization state relative to the linearly polarized broad stokes SC. From these polarization measurements we deduce the Raman depolarization ratio, the resonant versus nonresonant …
The effects of linearly increasing flip angles on 3D inflow MR angiography
1994
As recently demonstrated, spin saturation effects in 3D time-of-flight (TOF) MR angiography (MRA) can be reduced by using RF pulses with linearly increasing flip angles (ramp pulses) in the main direction of flow. We developed a model for calculating the signal distribution of proton flow within the excitation volume (slab) for different ramp slopes and compared the results with the measured distribution for the lower-leg arteries. The ramp pulses were generated using the Fourier transformation of the desired excitation profiles. With a bandwidth of 6 kHz and a pulse length of 2.56 ms satisfactory ramps with variable slopes were generated and applied in a standard flow-compensated 3D FISP s…
The Single Molecule Probe: Nanoscale Vectorial Mapping of Photonic Mode Density in a Metal Nanocavity
2009
International audience; We use superresolution single-molecule polarization and lifetime imaging to probe the local density of states (LDOS) in a metal nanocavity. Determination of the orientation of the molecular transition dipole allows us to retrieve the different LDOS behavior for parallel and perpendicular orientations with respect to the metal interfaces. For the perpendicular orientation, a strong lifetime reduction is observed for distances up to 150 nm from the cavity edge due to coupling to surface plasmon polariton modes in the metal. Contrarily, for the parallel orientation we observe lifetime variations resulting from coupling to characteristic λ/2 cavity modes. Our results are…
A one-pot method to enhance dissolution rate of low solubility drug molecules using dispersion polymerization in supercritical carbon dioxide
2009
The surfactant assisted polymerization of 1-vinyl-2-pyrrolidone in supercritical carbon dioxide in the presence of Piroxicam, selected as a model of a low aqueous solubility drug, was studied in order to prepare in a single step a polymeric composite to enhance the rate of dissolution of the pharmaceutical compound. Reactive entrapping was carried out at 65 degrees C in the P range 21-38MPa. Under proper operative conditions we obtained the composite under the form of sub-micron spherical particles with relatively narrow particle size distribution. Drug loadings higher than 12% (w/w) were obtained and XRD and Raman spectroscopy suggest that the anti-inflammatory agent is dispersed in the ma…
Engineering of Nanofibrous Amorphous and Crystalline Solid Dispersions for Oral Drug Delivery
2018
Poor aqueous solubility (<0.1 mg/mL) affects a significant number of drugs currently on the market or under development. Several formulation strategies including salt formation, particle size reduction, and solid dispersion approaches have been employed with varied success. In this review, we focus primarily on the emerging trends in the generation of amorphous and micro/nano-crystalline solid dispersions using electrospinning to improve the dissolution rate and in turn the bioavailability of poorly water-soluble drugs. Electrospinning is a simple but versatile process that utilizes electrostatic forces to generate polymeric fibers and has been used for over 100 years to generate synthet…
Experimentelle In-vitro-Studie zur Evaluierung eines elektronischen Detektors für die digitale Radiographie
2004
Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 kV; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR®, ADC®) and two conventional screen-film systems (Insight®, T-Mat®). Using a standardized protocol with a 4-point…
Advantages of fitting contrast curves using logistic function: a technical note.
2013
Objective The aim of this article is to demonstrate how the contrast properties of an imaging system can be ideally fitted with the use of stripe patterns and the logistic function. Study Design Stripe patterns with defined amounts of line pairs (lp/mm) per mm (10-20 lp/mm) were recorded with the use of digital photostimulable storage phosphor. Scan data and normalized image data were analyzed with the use of ImageJ and MatLab to calculate different contrast curves. Results For original scan data, the goodness of fit was 0.0000019 (sum of squared error [SSE]). The R-square was 0.9998. For normalized data the goodness of fit was 0.0007 (SSE) and the R-square 0.998. An amount of 50% contrast …
Quality management in higher education: A comparative study of the United Kingdom, the Netherlands and Finland
2010
This chapter examines lecturers’ perceptions of the balance between quality assurance and quality enhancement in three case study higher education institutions in different European countries. Where quality initiatives emphasised assurance rather than enhancement, this was taken to indicate a significant limitation on a lecturer’s autonomy in the quality management process. In-depth interviews using a semi-structured schedule were conducted with 20 randomly selected academic staff in each of the three higher education institutions. The results from the interviews demonstrated a very wide range of views among the interviewees. However, generally, it was found that there was a high level of d…
Myocardial fibrosis by delayed enhancement cardiovascular magnetic resonance and HCV infection in thalassemia major patients
2010
ss Open Acce Oral presentation Myocardial fibrosis by delayed enhancement cardiovascular magnetic resonance and HCV infection in thalassemia major patients Alessia Pepe1, Antonella Meloni1, Zelia Borsellino2, Maria Chiara Dell'Amico1, Vincenzo Positano1, Caterina Borgna-Pignatti3, Aurelio Maggio4, Gennaro Restaino5, Francesco Gagliardotto2, Paolo Cianciulli6, Luciano Prossomariti7, Aldo Filosa7, Michele Centra8, Domenico D'Ascola9, Antonella Quarta10, Angelo Peluso11, Antonello Pietrangelo12, Eliana Cracolici13, Massimo Lombardi*1 and Marcello Capra2
Low RNA translation activity limits the efficacy of hydrodynamic gene transfer to pig liver “in vivo”
2014
Background Hydrodynamic gene delivery has proved an efficient strategy for nonviral gene therapy in the murine liver but it has been less efficient in pigs. The reason for such inefficiency remains unclear. The present study used a surgical strategy to seal the whole pig liver in vivo. Methods A solution of enhanced green fluorescent protein (eGFP) DNA was injected under two different venous injection conditions (anterograde and retrograde), employing flow rates of 10 and 20 ml/s in each case, with the aim of identifying the best gene transfer conditions. The gene delivery and information decoding steps were evaluated by measuring the eGFP DNA, mRNA and protein copy number 24 h after transf…