Search results for "Enhancement."
showing 10 items of 557 documents
About Objective 3-D Analysis of Airway Geometry in Computerized Tomography
2008
The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…
Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography.
2005
In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous…
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging.
2010
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The pr…
Surpassing digital holography limits by lensless object scanning holography.
2012
We present lensless object scanning holography (LOSH) as a fully lensless method, capable of improving image quality in reflective digital Fourier holography, by means of an extremely simplified experimental setup. LOSH is based on the recording and digital post-processing of a set of digital lensless holograms and results in a synthetic image with improved resolution, field of view (FOV), signal-to-noise ratio (SNR), and depth of field (DOF). The superresolution (SR) effect arises from the generation of a synthetic aperture (SA) based on the linear movement of the inspected object. The same scanning principle enlarges the object FOV. SNR enhancement is achieved by speckle suppression and c…
Enhancing salty taste through odour–taste–taste interactions: Influence of odour intensity and salty tastants’ nature
2013
WOS:000315557500017 ; www.elsevier.com/locate/foodqual; International audience; Decreasing the sodium content in food products without changing consumer acceptability has become an important challenge for the food industry, and several strategies are currently under investigation to reach this goal. This study investigated the effectiveness of saltiness enhancement by an odour to maintain the perception of saltiness in reduced salt content solutions. In the first experiment, we tested the hypothesis that odour intensity drives the level of saltiness enhancement. The results showed that odour can increase the salty intensity by 25%, while no clear influence of odour intensity either in taste…
Experimental and Numerical Simulations of Flow and Heat Transfer in Heat Exchanger Elements Using Liquid Crystal Thermography
2004
Experimental and numerical investigation of heat transfer and fluid flow were conducted for classic heat exchanger elements (flat plate with fin-tubes in-line, staggered and with vortex generators) and corrugated-undulated ducts under transitional and weakly turbulent conditions. The dependence of average heat transfer and pressure drop on Reynolds number and geometrical parameters was investigated. Distributions of local heat transfer coefficient were obtained by using liquid crystal thermography and surface-averaged values were computed. Three-dimensional numerical simulations were conducted by a finite-volume method using a low-Reynolds number k-e model under the assumption of fully deve…
Can ECG-gated MDCT be considered an obligatory step to plan and manage a new chest-pain unit?
2007
The recent improvements in multi-detector computed tomography technology and its application in cardiac field allow to consider this non-invasive imaging technique as a promising comprehensive method for detecting significant coronary stenoses in a chest-pain unit. The possibility to use the ECG-synchronisation acquisition protocol, normally limited to the cardiac volume, for the entire thoracic vascular system should have the remarkable potential to reduce invasive and non-invasive procedures actually used to investigate acute chest pain and the number of unnecessary hospital admissions without reducing appropriate admissions in patients with chest pain.
Comprehensive cardiovascular ECG-gated MDCT as a standard diagnostic tool in patients with acute chest pain
2007
Acute myocardial infarction, pulmonary embolism, and aortic dissection are diseases associated with acute chest pain and may lead to severe morbidity and mortality. These diseases may not be trivial to diagnose in the settings of emergency room. ECG-gated multi-detector computed tomography (MDCT), already established for the assessment of pulmonary embolism and aortic dissection, provides reliable information regarding the triage of patients with acute coronary syndrome in the emergency room. MDCT recently appeared to be logistically feasible and a promising comprehensive method for the evaluation of cardiac and non-cardiac chest pain in emergency department patients. The possibility to sca…
Application of fluorescence spectroscopy and multispectral imaging for non-invasive estimation of GFP transfection efficiency
2014
Electroporation and ultrasound induced sonoporation has been showed to induce plasmid DNA transfection to the mice tibialis cranialis muscle. It offers new prospects for gene therapy and cancer treatment. However, numerous experimental data are still needed to deliver the plausible explanation of the mechanisms governing DNA electro- or sono-transfection, as well as to provide the updates on transfection protocols for transfection efficiency increase. In this study we aimed to apply non-invasive optical diagnostic methods for the real time evaluation of GFP transfection levels at the reduced costs for experimental apparatus and animal consumption. Our experimental set-up allowed monitoring …
Sensor Fusion Combining 3-D and 2-D for Depth Data Enhancement
2012
Time-of-Flight (ToF) cameras are known to be cost-efficient 3-D sensing systems capable of providing full scene depth information at a high frame rate. Among many other advantages, ToF cameras are able to provide distance information regardless of the illumination conditions and with no texture dependency, which makes them very suitable for computer vision and robotic applications where reliable distance measurements are required. However, the resolution of the given depth maps is far below the resolution given by standard 2-D video cameras which, indeed, restricts the use of ToF cameras in real applications such as those for safety and surveillance. In this thesis, we therefore investigate…