Search results for "Equipment Design"

showing 10 items of 409 documents

Multiplexed plasmon sensor for rapid label-free analyte detection.

2013

Efficient and cost-effective multiplexed detection schemes for proteins in small liquid samples would bring drastic advances to fields like disease detection or water quality monitoring. We present a novel multiplexed sensor with randomly deposited aptamer functionalized gold nanorods. The spectral position of plasmon resonances of individual nanorods, monitored by dark-field spectroscopy, respond specifically to different proteins. We demonstrate nanomolar sensitivity, sensor recycling, and the potential to upscale to hundreds or thousands of targets.

AnalyteMaterials scienceAptamerNanophotonicsProtein Array AnalysisBioengineeringNanotechnology02 engineering and technologyBiosensing Techniques010402 general chemistry01 natural sciencesMultiplexingNanotechnologyGeneral Materials ScienceSpectroscopyPlasmonLabel freeStaining and LabelingMechanical EngineeringProteinsGeneral ChemistryEquipment DesignSurface Plasmon Resonance021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesEquipment Failure AnalysisNanorod0210 nano-technologyNano letters
researchProduct

Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor

2012

We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…

AnalyteMaterials sciencegas detection; optical sensor; Bragg grating; cyclodextrin; aromatic hydrocarbonsTransducersaromatic hydrocarbonsAnalytical chemistryPhysics::OpticsNaphthaleneslcsh:Chemical technologyBiochemistryNoise (electronics)gas detectionArticleAnalytical ChemistryFiber Bragg gratinglcsh:TP1-1185Electrical and Electronic Engineeringoptical sensorInstrumentationDetection limitCyclodextrinsEquipment DesignAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryWavelengthTransducercyclodextrinSolventsBragg gratingGasesRefractometryRefractive indexSensors
researchProduct

Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…

2016

Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …

Analytical chemistry010501 environmental sciences01 natural sciencesHigh-performance liquid chromatographyAnalytical ChemistryAdsorptionColumn chromatographyLimit of DetectionPhase (matter)Sample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsChromatography High Pressure Liquid0105 earth and related environmental sciencesCyclodextrinsChromatographyChemistry010401 analytical chemistryExtraction (chemistry)Solid Phase ExtractionWaterMicroporous materialEquipment DesignSilicon Dioxide0104 chemical sciencesAdsorptionPorosityWater Pollutants ChemicalTalanta
researchProduct

Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…

2015

A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…

Analytical chemistrychemistry.chemical_elementNatural GasMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeLimit of DetectionEnvironmental ChemistryBenzeneSpectroscopyDetection limitAir PollutantsZeeman effectSpectrometerSpectrophotometry AtomicAbsorption RadiationBenzeneEquipment DesignTolueneMercury (element)WavelengthMercury IsotopeschemistrysymbolsEnvironmental MonitoringAnalytica chimica acta
researchProduct

Production and detection of atomic hexadecapole at Earth's magnetic field

2007

Anisotropy of atomic states is characterized by population differences and coherences between Zeeman sublevels. It can be efficiently created and probed via resonant interactions with light, the technique which is at the heart of modern atomic clocks and magnetometers. Recently, nonlinear magneto-optical techniques have been developed for selective production and detection of higher polarization moments, hexadecapole and hexacontatetrapole, in the ground states of the alkali atoms. Extension of these techniques into the range of geomagnetic fields is important for practical applications. This is because hexadecapole polarization corresponding to the $\Delta M=4$ Zeeman coherence, with maxim…

Angular momentumLightEarth PlanetMagnetometerAtomic Physics (physics.atom-ph)TransducersPopulationFOS: Physical sciencesRadiation Dosagelaw.inventionPhysics - Atomic PhysicsMagneticssymbols.namesakelawPhysical Sciences and MathematicsScattering RadiationComputer SimulationPhysics::Atomic PhysicsRadiometryAnisotropyeducationPhysicseducation.field_of_studyZeeman effectEquipment DesignModels TheoreticalPolarization (waves)Atomic and Molecular Physics and OpticsAtomic clockMagnetic fieldEquipment Failure AnalysisBudker [BRII recipient]symbolsComputer-Aided DesignAtomic physicsEnvironmental Monitoring
researchProduct

CardioPulse: developments in the treatment of aortic aneurysms in 2014

2015

Since the introduction of EndoVascular Aortic Repair (EVAR) for the treatment of abdominal aortic aneurysms (AAA) more than 20 years ago, the technique has evolved rapidly, from tubular grafts for fairly simple abdominal aortic anatomy, to bifurcated, fenestrated, branched, or parallel grafts for complex aortic aneurysms, no longer confined to the infrarenal abdominal aorta.

Aortic Aneurysm ThoracicAortic RuptureEndovascular ProceduresBiomedical Technology610 Medicine & healthEquipment DesignSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis10020 Clinic for Cardiac SurgeryBlood Vessel Prosthesis ImplantationHumansaortic aneurysmAortic Aneurysm Abdominal
researchProduct

Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thora…

2012

Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease.1–4 Fundamentally, it is a far less invasive approach than open surgery and its availability and relative ease of application has changed and extended management options in thoracic aortic disease, including in those patients deemed unfit or unsuitable for open surgery. In the operating room, this requires considerable perceptual, cognitive and psychomotor demands on the operators. The dramatic expansion of TEVAR activity has necessarily prompted a requirement to systematically consider the indications, appropriateness, limitations and…

Aortic archEndoleakMedizinAnastomotic LeakAorta ThoracicChest painPatient Care PlanningAortic aneurysmPostoperative ComplicationsIntraoperative ComplicationsBrain DiseasesEndovascular ProceduresAngiographyEquipment DesignGeneral MedicineTreatment OutcomeCardiothoracic surgeryDescending aortacardiovascular systemCardiologyStentsmedicine.symptomCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyConsensusAortic DiseasesPerioperative CareSpinal Cord DiseasesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryInternal medicineMonitoring IntraoperativemedicineHumansAortaAortic Aneurysm Thoracicbusiness.industryContraindicationsPatient SelectionVascular System Injuriesmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic DissectionSurgerybusinessTomography X-Ray ComputedEchocardiography TransesophagealEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Self-conscious robotic system design process-from analysis to implementation

2011

Developing robotic systems endowed with self-conscious capabilities means realizing complex sub-systems needing ad-hoc software engineering techniques for their modelling, analysis and implementation. In this chapter the whole process (from analysis to implementation) to model the development of self-conscious robotic systems is presented and the new created design process, PASSIC, supporting each part of it, is fully illustrated. © 2011 Springer Science+Business Media, LLC.

Biochemistry Genetics and Molecular Biology (all)Computer sciencebusiness.industryProcess (engineering)ConsciousneMedicine (all)Robotic paradigmsEquipment DesignModels TheoreticalRoboticRobotic systemsDesign processSoftware engineeringbusiness
researchProduct

Spin qubits with electrically gated polyoxometalate molecules

2007

Spin qubits offer one of the most promising routes to the implementation of quantum computers. Very recent results in semiconductor quantum dots show that electrically-controlled gating schemes are particularly well-suited for the realization of a universal set of quantum logical gates. Scalability to a larger number of qubits, however, remains an issue for such semiconductor quantum dots. In contrast, a chemical bottom-up approach allows one to produce identical units in which localized spins represent the qubits. Molecular magnetism has produced a wide range of systems with tailored properties, but molecules permitting electrical gating have been lacking. Here we propose to use the polyox…

Biomedical EngineeringFOS: Physical sciencesBioengineeringComputers MolecularComputer Science::Emerging TechnologiesQuantum mechanicsMesoscale and Nanoscale Physics (cond-mat.mes-hall)NanotechnologyComputer SimulationGeneral Materials ScienceElectrical and Electronic EngineeringQuantumQuantum computerSpin-½PhysicsCondensed Matter - Materials ScienceCondensed Matter - Mesoscale and Nanoscale PhysicsSpinsElectric ConductivityMaterials Science (cond-mat.mtrl-sci)Signal Processing Computer-AssistedSpin engineeringEquipment DesignTungsten CompoundsCondensed Matter PhysicsAtomic and Molecular Physics and OpticsModels ChemicalSemiconductorsQubitComputer-Aided DesignQuantum TheoryLoss–DiVincenzo quantum computerSuperconducting quantum computing
researchProduct

A novel device for intracolonoscopy cleansing of inadequately prepared colonoscopy patients: a feasibility study.

2019

Abstract Background The importance of high quality preprocedural bowel preparation is widely acknowledged, but suboptimal bowel cleansing still occurs in up to 20 % of all colonoscopy patients. The aim of this study was to evaluate the performance of a novel intraprocedural cleaning device for cleaning poorly prepared colons. Methods This multicenter feasibility study included patients aged 18 – 75 years who were referred for colonoscopy. Intraprocedural cleaning was performed in patients after a limited preprocedural bowel preparation regimen (2 days of dietary restrictions and 2 × 10 mg bisacodyl). The primary outcome was the proportion of adequately prepared patients (Boston Bowel Prepar…

BisacodylMalemedicine.medical_specialtyColonColonoscopyOther Research Radboud Institute for Molecular Life Sciences [Radboudumc 0]Drug Administration SchedulePolyethylene GlycolsTumours of the digestive tract Radboud Institute for Health Sciences [Radboudumc 14]03 medical and health sciencesAll institutes and research themes of the Radboud University Medical Center0302 clinical medicinePatient satisfactionInterquartile rangemedicineHumansNew deviceBisacodylTherapeutic IrrigationIntraoperative Caremedicine.diagnostic_testbusiness.industryCatharticsGastroenterologyCecal intubationColonoscopyEquipment DesignMiddle AgedSurgeryClinical trialRegimenTreatment OutcomePatient Satisfaction030220 oncology & carcinogenesisInflammatory diseases Radboud Institute for Health Sciences [Radboudumc 5]Feasibility Studies030211 gastroenterology & hepatologyFemalebusinessmedicine.drugEndoscopy
researchProduct