Search results for "Equivalent"

showing 10 items of 308 documents

Reaction of 4,5-diamino-1,6-dihydropyrimidin-6-ones with two equivalents of chalcones

1995

The reaction of 4,5-diamino-1,6-dihydropyrimidin-6-ones 1 with two equivalents of the chalcones 2 leads in an acidic medium to the formation of the 2,3,6,7-tetrahydro-1H-pyrimido[4,5-b][1,4]diazepin-6-one derivatives 3a-d. The structure elucidation of the products is based on nmr measurements and an X-ray diffraction.

DiffractionEquivalentChemistryOrganic ChemistryMedicinal chemistryJournal of Heterocyclic Chemistry
researchProduct

2,3,7,8-tetrachlorodibenzo-p-dioxin equivalents in extracts of Baltic white-tailed sea eagles

1997

Concentrations of 2,3,7,8-tetrachlorodibenzo-p-dioxin-(TCDD) equivalents were measured in extracts of Baltic white-tailed sea eagle tissues. Extracts of salmon, ringed seal, and grey seal were analyzed as other predatory species of the same area. Concentrations in eagle and seal tissues were greater than those in salmon. Concentrations of TCDD equivalents (TCDD-EQs) determined by the H4IIE bioassay were compared with toxic equivalents (TEQs) derived from instrumental chemical analyses in fractions containing polychlorinated dibenzo-P-dioxins and polychlorinated dibenzofurans (PCDD/PCDF) or coplanar polychlorinated biphenyls (PCBs). Toxic equivalents were calculated by use of an additive mod…

EaglePollutantendocrine systembiologyChemistryHaliaeetus albicillaHealth Toxicology and Mutagenesisbiology.organism_classificationEquivalentbiology.animalEnvironmental chemistryAccipitridaeEnvironmental ChemistryBioassayheterocyclic compoundsWater pollutionPolychlorinated dibenzofuransEnvironmental Toxicology and Chemistry
researchProduct

Gradual caldera collapse at Bardarbunga volcano, Iceland, regulated by lateral magma outflow

2016

Large volcanic eruptions on Earth commonly occur with a collapse of the roof of a crustal magma reservoir, forming a caldera. Only a few such collapses occur per century, and the lack of detailed observations has obscured insight into the mechanical interplay between collapse and eruption.We usemultiparameter geophysical and geochemical data to show that the 110-square kilometer and 65-meter-deep collapse of Bárdarbunga caldera in 2014–2015 was initiated through withdrawal of magma, and lateral migration through a 48-kilometers-long dike, from a 12-kilometers deep reservoir. Interaction between the pressure exerted by the subsiding reservoir roof and the physical properties of the subsurfac…

EldgosLateral eruption010504 meteorology & atmospheric sciencesLavaÖskjugosHraunrennsli010502 geochemistry & geophysics01 natural sciences[SDU.STU.GC]Sciences of the Universe [physics]/Earth Sciences/GeochemistryCalderaComputingMilieux_MISCELLANEOUS0105 earth and related environmental sciencesgeographygeography.geographical_feature_categoryMultidisciplinaryGlacier DynamicsResurgent domeMedicine (all)Complex volcanoLateral Magma Flow16. Peace & justiceCaldera collapseDense-rock equivalentBárðarbungaVolcano13. Climate actionEruptionMagmaGeologySeismology
researchProduct

Equivalent circuit analysis of solid-rotor induction machines with reference to turbocharger accelerator applications

2006

Theoretical, numerical and experimental studies are described that have been carried out to develop a solid-rotor induction machine design for a particularly demanding application as an accelerator drive for a diesel engine turbocharger. In this application the turbo-motor will be required to operate at speeds of up to 130 000 rpm and in temperatures that can exceed 200°C. The results show that the equivalent circuit gives predictions that are of sufficient precision for design purposes and provides a useful design tool. It is shown that the use of a solid rotor affects the value of the stator leakage reactance and influences the motor performance through this effect as well as by presentin…

Electric machineLeakage inductanceEngineeringbusiness.product_categoryRotor (electric)business.industryStatorDesign toolAutomotive engineeringlaw.inventionlawTurbomachineryEquivalent circuitElectrical and Electronic EngineeringbusinessTurbochargerIEE Proceedings - Electric Power Applications
researchProduct

A new empirical method for extracting unloaded resonant frequencies from microwave resonant cavities

2003

Equivalent circuits traditionally used to model resonators and coupling networks in the vicinity of a resonance provide values of unloaded resonant frequencies which usually do not agree with experimental results. A new empirical method for the extraction of influence of coupling networks on resonant cavities is presented. The characterization of coupling structures is performed directly from measurements without the need of obtaining the electromagnetic fields inside the cavity, which is very interesting from a practical point of view. Results are validated with simulations and experimental measurements. The accuracy of some cavity applications, such as dielectric characterization techniqu…

Electromagnetic fieldCouplingResonatorMaterials scienceAcousticsElectronic engineeringResonanceEquivalent circuitCoupling coefficient of resonatorsMicrowaveMicrowave cavity
researchProduct

Design, assembly and characterization of silicide-based thermoelectric modules

2016

ID: 1143 In: Energy conversion and management, 13-21. Summary: Highlights•Novel silicide-based thermoelectric modules were experimentally investigated.•The modules produced high power of 1.04 W at 405 °C and 3.24 W at 735 °C.•An estimated module efficiency of 5.3% represent the highest reported for silicide systems.AbstractSilicides have attracted considerable attention for use in thermoelectric generators due mainly to low cost, low toxicity and light weight, in contrast to conventional materials such as bismuth and lead telluride. Most reported work has focused on optimizing the materials properties while little has been done on module testing. In this work we have designed and tested mod…

Energy storageThermoelectric equipment02 engineering and technology7. Clean energyThermal expansionBismuthchemistry.chemical_compoundDegradationMagnesium silicideHigher manganese silicideSilicide0202 electrical engineering electronic engineering information engineeringHigher manganese silicidesMagnesiumThermo-Electric materialsThermal expansion mismatchDirect energy conversion[CHIM.MATE]Chemical Sciences/Material chemistryThermoelectric materialsMagnesium silicides[CHIM.THEO]Chemical Sciences/Theoretical and/or physical chemistryConversion directeFuel TechnologyThermal expansionSilicidesMaterials scienceMaximum power principleCharacterization020209 energyEnergy Engineering and Power Technologychemistry.chemical_elementMagnesium silicideThermoelectric moduleThermo-electric modulesElectronic engineering[CHIM.CRIS]Chemical Sciences/Cristallography[CHIM]Chemical SciencesManganeseRenewable Energy Sustainability and the EnvironmentEquivalent circuitsThermoelectricityEngineering physicsLead tellurideThermoelectric generatorCross-section areaNuclear Energy and EngineeringchemistryEnergy transferConventional materialsÉnergieMaterials propertiesThermoelectric generatorsMaterials testing
researchProduct

Analysis of voltage dips propagation in MV distribution networks by using ATP-EMTP code

2003

In this paper, voltage dips simulation in electric power MV distribution networks by using an improved ATP circuit-breaker model are reported. An equivalent circuit of a MV distribution system is employed. The circuit-breaker is simulated by using a tool written in MODELS language and by arranging a time-variable differential arc-conductance based on the combination of Mayr's and Cassie's equations. The simulations carried out have shown how the amplitude of the voltage dips depends on the type and location of the fault and their duration is strictly related to the circuit-breaker parameters.

EngineeringEmtpbusiness.industryElectrical engineeringHardware_PERFORMANCEANDRELIABILITYTopologyFault (power engineering)Computer Science::Hardware ArchitecturePower system simulationAmplitudeEquivalent circuitElectric powerbusinessCircuit breakerVoltage1999 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.99EX147)
researchProduct

Evaluation of infilled frames: an updated in-plane-stiffness macro-model considering the effects of vertical loads

2015

The influence of masonry infills on the in-plane behaviour of RC framed structures is a central topic in the seismic evaluation and retrofitting of existing buildings. Many models in the literature use an equivalent strut member in order to represent the infill but, among the parameters influencing the equivalent strut behaviour, the effect of vertical loads acting on the frames is recognized but not quantified. Nevertheless a vertical load causes a non-negligible variation in the in-plane behaviour of infilled frames by influencing the effective volume of the infill. This results in a change in the stiffness and strength of the system. This paper presents an equivalent diagonal pin-jointed…

EngineeringEquivalent diagonal pin-jointed strut modelInfilled framesDiagonalIn-plane behaviourInfilled frames In-plane behaviour Equivalent diagonal pin-jointed strutmodel Vertical load influenceVertical load influenceComputer Science::Computational Engineering Finance and SciencemedicineInfillRetrofittingGeotechnical engineeringMacroCivil and Structural Engineeringmodelbusiness.industryStiffnessStructural engineeringBuilding and ConstructionMasonryGeotechnical Engineering and Engineering GeologyEquivalent diagonal pin-jointed strutFinite element methodStiffeningSettore ICAR/09 - Tecnica Delle CostruzioniGeophysicsmedicine.symptombusinessInfilled frame
researchProduct

Prediction of the additional shear action on frame members due to infills

2014

Infill masonry walls in framed structures make a significant contribution to the response under seismic actions. With special regard to reinforced concrete (RC) structures, it is known that internal forces modifications caused by the frame–infill interaction may be not supported by the surrounding frame because of the additional shear forces arising at the ends of beams and columns. Such additional forces may lead to the activation of brittle collapse mechanisms and hence their prediction is basic in capacity assessment, especially for structures that disregard the details for seismic zones. In this paper a parametric study is carried out addressed to the prediction of the shear forces ment…

EngineeringInfilled framesMasonry infillsbusiness.industryInfilled frames; Masonry infills; Local shear effects; Micromodel; Equivalent strut.Shear forceBuilding and ConstructionStructural engineeringMasonryConcentricGeotechnical Engineering and Engineering GeologyInfilled framesSettore ICAR/09 - Tecnica Delle CostruzioniMicromodelGeophysicsBrittlenessShear (geology)InfillEquivalent strutGeotechnical engineeringInfilled frames · Masonry infills · Local shear effects · Micromodel · Equivalent strutbusinessLocal shear effectsCivil and Structural EngineeringParametric statisticsBulletin of Earthquake Engineering
researchProduct

An efficient analytical approach for obtaining a five parameters model of photovoltaic modules using only reference data

2013

Exploiting the equivalent one-diode circuit of a photovoltaic (PV) module, this paper proposes a novel and fully analytical model to predict the electrical performance upon solar irradiance intensity and PV module temperature. The model refers essentially to an equivalent circuit governed by five parameters and the extraction of them permits to describe the current–voltage curve of the PV panel and consequently permits to assess the energy output of PV modules. The proposed model extracts the five characteristic parameters using only exact analytical relationship and tabular data always available such as short-circuit current, open circuit voltage and the Maximum Power Point (MPP). The diff…

EngineeringMathematical optimizationSettore ING-IND/11 - Fisica Tecnica AmbientaleOptimization problemMaximum power principlebusiness.industryMechanical EngineeringPhotovoltaic systemReference data (financial markets)Building and ConstructionManagement Monitoring Policy and LawSystem of linear equationsSizingGeneral EnergyEquivalent circuitPhotovoltaic panel five parameter model reference data I-V characteristicbusinessAlgorithmEnergy (signal processing)Applied Energy
researchProduct