Search results for "Experimental technique"
showing 10 items of 227 documents
Operational experience with a large detector system using silicon strip detectors with double sided readout
1992
Abstract A large system of silicon strip detectors with double sided readout has been successfully commissioned over the course of the last year at the e + e − collider LEP. The readout of this 73 728 channel system is performed with custom designed VLSI charge sensitive amplifier chips (CAMEX64A). An overall point resolution of 12 μm on both sides has been acheived for the complete system. The most important difficulties during the run were beam losses into the detector, and a chemical agent deposited onto the electronics; however, the damage from these sources was understood and brought under control. This and other results of the 1991 data-taking run are described with special emphasis o…
Mechanisms of Electron-Induced Single-Event Latchup
2019
In this paper, possible mechanisms by which electrons can induce single-event latchups in electronics are discussed. The energy deposition and the nuclear fragments created by electrons in silicon are analyzed in this context. The cross section enhancement effect in the presence of high-Z materials is discussed. First experimental results of electron-induced latchups are shown in static random access memory devices with low linear energy transfer thresholds. The radiation hardness assurance implications and future work are discussed.
Laser resonance ionization scheme development for tellurium and germanium at the dual Ti:Sa–Dye ISOLDE RILIS
2016
Abstract The resonance ionization laser ion source (RILIS) is the principal ion source of the ISOLDE radioactive beam facility based at CERN. Using the method of in-source laser resonance ionization spectroscopy, a transition to a new autoionizing state of tellurium was discovered and applied as part of a three-step, three-resonance, photo-ionization scheme. In a second study, a three-step, two-resonance, photo-ionization scheme for germanium was developed and the ionization efficiency was measured at ISOLDE. This work increases the range of ISOLDE RILIS ionized beams to 31 elements. Details of the spectroscopy studies are described and the new ionization schemes are summarized.
Data Blinding for the nEDM Experiment at PSI
2020
Psychological bias towards, or away from, prior measurements or theory predictions is an intrinsic threat to any data analysis. While various methods can be used to try to avoid such a bias, e.g. actively avoiding looking at the result, only data blinding is a traceable and trustworthy method that can circumvent the bias and convince a public audience that there is not even an accidental psychological bias. Data blinding is nowadays a standard practice in particle physics, but it is particularly difficult for experiments searching for the neutron electric dipole moment (nEDM), as several cross measurements, in particular of the magnetic field, create a self-consistent network into which it …
Upgrade of ATLAS hadronic Tile Calorimeter for the High-Luminosity LHC
2022
The Tile Calorimeter (TileCal) is a sampling hadronic calorimeter covering the central region of the ATLAS experiment, with steel as absorber and plastic scintillators as active medium. The High-Luminosity phase of LHC, delivering five times the LHC nominal instantaneous luminosity, is expected to begin in 2028. TileCal will require new electronics to meet the requirements of a 1 MHz trigger, higher ambient radiation, and to ensure better performance under high pile-up conditions. Both the on- and off-detector TileCal electronics will be replaced during the shutdown of 2026-2028. The TileCal upgrade program has included extensive R&D and test beam studies. A Demonstrator module with reverse…
Isotopic Enriched and Natural SiC Junction Barrier Schottky Diodes Under Heavy Ion Irradiation
2022
The radiation tolerance of isotopic enriched and natural silicon carbide junction barrier Schottky diodes are compared under heavy ion irradiation. Both types of devices experience leakage current degradation as well as single-event burnout events. The results were comparable, although the data may indicate a marginally lower thresholds for the isotopic enriched devices at lower linear energy transfer (LET). Slightly higher reverse bias threshold values for leakage current degradation were also observed compared to previously published work.
Study of radial motion phase advance during motion excitations in a Penning trap and accuracy of JYFLTRAP mass spectrometer
2021
Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic uncertainties that impose limitations on the accuracy of measurements are discussed. It was found out that the phase evolution of the radial motion of ions in a Penning trap during the application of radio-frequency fields leads to a systematic cyclotron frequency shift when more than one ion species is present in the trap during the cyclotron frequency measurement. An analytic expression was derived to correctly account for the shift. Cross-reference mass…
Assessment of Proton Direct Ionization for the Radiation Hardness Assurance of Deep Submicron SRAMs Used in Space Applications
2021
Proton direct ionization from low-energy protons has been shown to have a potentially significant impact on the accuracy of prediction methods used to calculate the upset rates of memory devices in space applications for state-of-the-art deep sub-micron technologies. The general approach nowadays is to consider a safety margin to apply over the upset rate computed from high-energy proton and heavy ion experimental data. The data reported here present a challenge to this approach. Different upset rate prediction methods are used and compared in order to establish the impact of proton direct ionization on the total upset rate. No matter the method employed the findings suggest that proton dir…
Measurement of proton and nitrogen polarization in ammonia and a test of equal spin temperature
1998
The 1996 data taking of the SMC experiment used polarized protons to measure the spin-dependent structure function g(1) of the proton. Three liters of solid granular ammonia were irradiated at the Bonn electron linac in order to create the paramagnetic radicals which are needed for polarizing the protons. Proton polarizations of +/- (90 +/- 2.5)% were routinely reached. An analysis based on a theoretical line shape for spin-1. systems with large quadrupolar broadening was developed which allowed the nitrogen polarization in the ammonia to be determined with a 10% relative error. The measured quadrupolar coupling constant of N-14 agrees well with earlier extrapolated values. The polarization…
The Pion Single-Event Effect Resonance and its Impact in an Accelerator Environment
2020
International audience; The pion resonance in the nuclear reaction cross section is seen to have a direct impact on the single-event effect (SEE) cross section of modern electronic devices. This was experimentally observed for single-event upsets and single-event latchup. Rectangular parallelepiped (RPP) models built to fit proton data confirm the existence of the pion SEE cross-section resonance. The impact on current radiation hardness assurance (RHA) soft error rate (SER) predictions is, however, minimal for the accelerator environment since this is dominated by high neutron fluxes. The resonance is not seen to have a major impact on the high-energy hadron equivalence approximation estab…