Search results for "Failure analysis"

showing 10 items of 132 documents

In-situ NDT testing procedure as an integral part of failure analysis of historical masonry arch bridges

2015

Abstract A nineteenth-century masonry arch bridge was analyzed as an illustrative example to explain the role of in-situ test campaigns in failure analysis and retrofit design. Test results were studied to find out the advantages of each technique, with the aim of proposing an optimized in-situ testing procedure. Standard static penetrometer, flat jack, thermographic and georadar in-situ tests were conducted. Traffic effects were analyzed by means of vibrational tests. The experimental analysis performed to investigate damage on the bridge structures shows the degree of reliability offered by each technique in evaluating specific information and reproducing the global behavior of the struct…

Failure analysisEngineeringFinite element methodDrawingBridge (nautical)law.inventionHistorical arch bridgeEngineering (all)lawNondestructive testingDiagnosisForensic engineeringGeneral Materials ScienceFailure analysiMasonryMasonry; Historical arch bridges; Failure analysis; Diagnosis; Drawing; Finite element methodReliability (statistics)business.industryGeneral EngineeringStructural engineeringMasonryHistorical arch bridgesPenetrometerFinite element methodMaterials Science (all)businessMasonry archDiagnosi
researchProduct

multimodal and multi-criteria analysis for the expertise and locating faults in modern electrical components

2017

The purpose of this manuscript is to exhibit the research work solving the issue of data processing stem from defect localization techniques. This step being decisive in the failure analysis process, scientists have to harness data coming from light emission and laser techniques. Nevertheless, this analysis process is sequential and only depends on the expert’s decision. This factor leads to a not quantified probability of localization. Consequently to solve these issues, a multimodaland multicriteria analysis has been developped, taking advantage of the heterogeneous and complementary nature of light emission and laser probing techniques. This kind of process is based on advanced level too…

Failure analysisFusion de donnéesTraitement d'imagesImage ProcessingSignal ProcessingAnalyse de défaillanceData fusionTraitement du signal[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Multimodal and multicriteria analysis for VLSI expertises and defects localization

2017

The purpose of this manuscript is to exhibit the research work solving the issue of data processing stem from defect localization techniques. This step being decisive in the failure analysis process, scientists have to harness data coming from light emission and laser techniques. Nevertheless, this analysis process is sequential and only depends on the expert’s decision. This factor leads to a not quantified probability of localization. Consequently to solve these issues, a multimodal and multicriteria analysis has been developped, taking advantage of the heterogeneous andcomplementary nature of light emission and laser probing techniques. This kind of process is based on advanced level too…

Failure analysisdata fusionAnalyse de défaillancescircuits intégrés[SPI.NANO] Engineering Sciences [physics]/Micro and nanotechnologies/Microelectronicsanalyse multimodale et multicritèrestraitement du signal/imagesignal/image processingVLSI[STAT] Statistics [stat]multimodal and criteria analysisdefect localizationlocalisation de défauts[PHYS.PHYS.PHYS-DATA-AN] Physics [physics]/Physics [physics]/Data Analysis Statistics and Probability [physics.data-an]fusion de données[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Diffractive optics for quasi-direct space-to-time pulse shaping.

2008

The strong chromatic behavior associated with a conventional diffractive lens is fully exploited to propose a novel optical device for pulse shaping in the femtosecond regime. This device consists of two optical elements: a spatially patterned circularly symmetric mask and a kinoform diffractive lens, which are facing each other. The system performs a mapping between the spatial position of the masking function expressed in the squared radial coordinate and the temporal position in the output waveform. This space-to-time conversion occurs at the chromatic focus of the diffractive lens, and makes it possible to tailor the output central wavelength along the axial location of the output point…

Femtosecond pulse shapingMasking (art)LightDiffractive lensesPhysics::OpticsDiffraction efficiencyOpticsScattering RadiationComputer SimulationChromatic scalePhysicsPulse shapingKinoformbusiness.industryFísicaOptical DevicesSignal Processing Computer-AssistedEquipment DesignModels TheoreticalPulse shapingAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryFemtosecondComputer-Aided DesignFocus (optics)businessOptics express
researchProduct

Femtosecond parabolic pulse shaping in normally dispersive optical fibers

2013

Formation of parabolic pulses at femtosecond time scale by means of passive nonlinear reshaping in normally dispersive optical fibers is analyzed. Two approaches are examined and compared: the parabolic waveform formation in transient propagation regime and parabolic waveform formation in the steady-state propagation regime. It is found that both approaches could produce parabolic pulses as short as few hundred femtoseconds applying commercially available fibers, specially designed all-normal dispersion photonic crystal fiber and modern femtosecond lasers for pumping. The ranges of parameters providing parabolic pulse formation at the femtosecond time scale are found depending on the initia…

Femtosecond pulse shapingOptical fiberMaterials scienceLightPhysics::Opticslaw.inventionOpticslawDispersion (optics)ChirpFiber Optic TechnologyScattering RadiationComputer Simulationbusiness.industryPulse durationSignal Processing Computer-AssistedEquipment DesignModels TheoreticalSurface Plasmon ResonanceÒpticaPulse shapingAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryFemtosecondComputer-Aided DesignbusinessPhotonic-crystal fiber
researchProduct

Pulse quality analysis on soliton pulse compression and soliton self-frequency shift in a hollow-core photonic bandgap fiber.

2013

A numerical investigation of low-order soliton evolution in a proposed seven-cell hollow-core photonic bandgap fiber is reported. In the numerical simulation, we analyze the pulse quality evolution in soliton pulse compression and soliton self-frequency shift in three fiber structures with different cross-section sizes. In the simulation, we consider unchirped soliton pulses (of 400 fs) at the wavelength of 1060 nm. Our numerical results show that the seven-cell hollow-core photonic crystal fiber, with a cross-section size reduction of 2%, promotes the pulse quality on the soliton pulse compression and soliton self-frequency shift. For an input soliton pulse of order 3 (which corresponds to…

Femtosecond pulse shapingPhysicsPhotonsOptical fiberbusiness.industryPhysics::OpticsSoliton (optics)Equipment DesignSurface Plasmon ResonancePulse shapingAtomic and Molecular Physics and Opticslaw.inventionPulse (physics)Equipment Failure AnalysisRefractometryOpticslawPulse compressionOptoelectronicsFiber Optic TechnologybusinessNonlinear Sciences::Pattern Formation and SolitonsUltrashort pulsePhotonic-crystal fiberOptics express
researchProduct

Multicomponent polymeric micelles based on polyaspartamide as tunable fluorescent pH-window biosensors

2010

Abstract PHEA-PEG 5000 -C 16 is a polyaspartamide polymer with appended hydrophilic PEG 5000 functions and hydrophobic n-C 16 units forming biocompatible micelles with a CAC as low as 1.8 × 10 −7  M. The protonation and acidity constants of the polymer's amino and carboxylic groups have been determined by potentiometric titrations at five different concentrations higher than CAC, finding concentration-independent values. Viscosity and polarity of the micellar core have been investigated by means of fluorescent probes, finding local values comparable to those of pure toluene and to the core of sodium dodecyl sulphate micelles, independently on the protonation degree of the polymer. The fluor…

FluorophorePolymeric micelles Fluorescent biosensor PH window Self-assemblinGInorganic chemistryPotentiometric titrationBiomedical EngineeringBiophysicsProtonationBiosensing TechniquesMicellePolyethylene Glycolschemistry.chemical_compoundElectrochemistryOrganic chemistryMicellesPolyhydroxyethyl Methacrylatechemistry.chemical_classificationEquipment DesignGeneral MedicinePolymerHydrogen-Ion ConcentrationEquipment Failure AnalysisSpectrometry FluorescencechemistrySettore CHIM/09 - Farmaceutico Tecnologico ApplicativoPyreneSelf-assemblyPeptidesBiosensorBiotechnologyBiosensors and Bioelectronics
researchProduct

Twin axial vortices generated by Fibonacci lenses.

2013

Optical vortex beams, generated by Diffractive Optical Elements (DOEs), are capable of creating optical traps and other multifunctional micromanipulators for very specific tasks in the microscopic scale. Using the Fibonacci sequence, we have discovered a new family of DOEs that inherently behave as bifocal vortex lenses, and where the ratio of the two focal distances approaches the golden mean. The disctintive optical properties of these Fibonacci vortex lenses are experimentally demonstrated. We believe that the versatility and potential scalability of these lenses may allow for new applications in micro and nanophotonics.

Fresnel zoneFibonacci numberDevils vortex-lensesLightNanophotonicsPhysics::OpticsMicroscopic scaleOpticsLight beamScattering RadiationGolden ratioComputer SimulationDiffractive opticsLensesPhysicsOptical vorticesbusiness.industryFractal zone platesEquipment DesignModels TheoreticalAtomic and Molecular Physics and OpticsVortexEquipment Failure AnalysisRefractometryFISICA APLICADAComputer-Aided DesignbusinessOptical vortexDiffractionOptics express
researchProduct

Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

2014

In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields…

HDR brachytherapyMaterials sciencesuperficial and interstitialmedicine.medical_treatmentBrachytherapyBrachytherapydosimetric perturbationModels BiologicalSensitivity and SpecificityImaging phantomLead shieldingOpticsRadiation ProtectionShieldBody surfacemedicineHumansScattering RadiationComputer SimulationRadiometryWaste Management and DisposalMonte Carlo simulationbusiness.industrytransmissionPublic Health Environmental and Occupational HealthAbsorption RadiationReproducibility of ResultsRadiotherapy DosageGeneral MedicineEquipment DesignHigh-Dose Rate BrachytherapyEquipment Failure AnalysisLeadElectromagnetic shieldinglead shieldbusinessNuclear medicineBolus (radiation therapy)Journal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy

2014

Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent potential failures. In the application of traditional FMECA, the risk priority number (RPN) is determined to rank the failure modes; however, the method has been criticised for having several weaknesses. Moreover, it is unable to adequately deal with human errors or negligence. In this paper, a new versatile fuzzy rule-based assessment model is proposed to evaluate the RPN index to rank both component failure and human error. The proposed methodology is applied to potential radiological over-exposure of patients during high-dose-rate brach…

HDR brachytherapySafety ManagementComputer sciencemedicine.medical_treatmentBrachytherapyHuman errorBrachytherapyRisk AssessmentRadiation ProtectionComponent (UML)medicineHumansComputer SimulationRadiation InjuriesWaste Management and Disposalhuman errorSettore ING-IND/19 - Impianti Nuclearirisk priority numberModels StatisticalFuzzy ruleMedical ErrorsIncidenceRank (computer programming)Public Health Environmental and Occupational HealthGeneral MedicineReliability engineeringEquipment Failure AnalysisSurvival RateFailure mode effects and criticality analysisEquipment FailurePatient Safetyfuzzy logicRadioactive Hazard ReleaseRisk assessmentFailure mode and effects analysisFMECA
researchProduct