Search results for "Gas chromatography–mass spectrometry"
showing 10 items of 199 documents
First-order derivative resolution of overlapped PAH peaks with common mass spectra in gas chromatography–mass spectrometry
2007
Abstract First-order derivative of 15 points smoothed chromatograms of mixtures of benzo( b )fluoranthene (BbF) and benzo( k )fluoranthene (BkF) for the m / z 252 ion obtained using two microscans has been proposed as a simple alternative to the resolution of overlapped chromatographic peaks of these two compounds which have identical mass spectra. The procedure provides limits of detection of 12 and 29 ng g −1 for BbF and BkF, respectively and offers the possibility to use the 250 and 248 ions to confirm the identity of these analytes.
Contributions to the analysis of organic xenobiotics in fish
1995
For the residue-analysis of fish samples, a method has been developed to separate the medium polar triazines and acetamides together with lipophilic xenobiotics (organochlorine pesticides, PCBs and octachlorostyrene) from fish tissue. The detection limits of the analytes are mostly within the ppt-range (ng/kg fillet) and vary between 40 and 1050 ng/kg fillet of fish. Their recoveries range from 75 to 108%, spiked at 1.5 μg/kg. The substances are extracted with a mixture of petroleum ether/ethylacetate (2:1) using a soxhlet apparatus. Subsequently, the lipids in the sample extracts are reduced to 0.4% by gel chromatography. A 5 g silica gel clean-up separates the analytes according to their …
Comparison of different methods for extraction of polycyclic aromatic hydrocarbons (PAHs) from Sicilian (Italy) coastal area sediments.
2012
This paper describes a work aimed at improving the conditions of an extraction method, coupling GC-MS determination, for the analysis without cleanup phase, of polycyclic aromatic hydrocarbons (PAHs) from sediment samples. The automatic Soxhlet extraction in warm mode (using Extraction System B-811 Standard, Buchi) has demonstrated advantages for automation, reduced extraction time, and lower solvent use than for conventional Soxhlet extraction. Under these conditions, the recoveries are very good as they resulted greater than 85 % and, in most of the cases, near 100 %. The repeatability is also satisfactory (relative standard deviation less than 15 %). The detection limits are also accepta…
Validated, non-destructive and environmentally friendly determination of cocaine in euro bank notes.
2005
A non-destructive, fast and environmentally friendly procedure has been developed for cocaine determination in euro bank notes. Cocaine was extracted with 15 ml methanol by vortex agitation during 5 min. The extract was evaporated and reconstituted in 0.5 ml methanol. GC-MS-MS analysis was performed using as precursor ion m/z 182.2, with an excitation energy voltage of 1.60 eV, being the product ions measured m/z 150.2 and 82.0. A limit of detection of 0.15 ng per note and a repeatability of 6%, established from the relative standard deviation, of a 1 ng ml(-1) level, were achieved. Recoveries of 101+/-2 and 98+/-3% were obtained for samples spiked with 100 and 10 microg respectively. Resul…
Green, rapid and simultaneous determination of ‘alternative preservatives’ in cosmetic formulations by gas chromatography-mass spectrometry
2022
Abstract Some hydroxylated compounds commonly used in cosmetic formulations including short chain glycols, benzylic alcohols, and organic acids show antimicrobial activity, although they are not considered as preservatives according to the existing European legislation. These ‘alternative preservatives’ are not exempt of potential side-effects for cosmetics users. The aim of this work is to develop a simple and affordable analytical method useful for the simultaneous and green determination of fourteen compounds used as ‘alternative preservatives’ in cosmetic samples with different matrices. The proposed method allows a rapid sample preparation by simple dissolution or dispersion of the sam…
Determination of the new psychoactive substance dichloropane in saliva by microextraction by packed sorbent – Ion mobility spectrometry
2018
Abstract A simple procedure based on microextraction by packed sorbent (MEPS) has been proposed for the extraction of dichloropane in oral fluids and its determination by ion mobility spectrometry (IMS). Extraction conditions such as type of sorbent (octyl and octadecyl silica), sample pH, number of sample loadings, and elution volume were evaluated to obtain the most appropriate values. Dichloropane was extracted from saliva samples using C8 MEPS, loading with 100 μL sample (adjusted to pH 7) in 4 cycles, washing with 100 μL deionized water, and eluting with 50 μL 2-propanol in 10 cycles. The proposed MEPS procedure has been validated in terms of linearity, accuracy, and precision. A limit…
Determination of ultraviolet filters in bathing waters by stir bar sorptive–dispersive microextraction coupled to thermal desorption–gas chromatograp…
2015
In this work, a new approach that combines the advantages of stir bar sorptive extraction (SBSE) and dispersive solid phase extraction (DSPE), i.e. stir bar sorptive-dispersive microextraction (SBSDµE), is employed as enrichment and clean-up technique for the sensitive determination of eight lipophilic UV filters in water samples. The extraction is accomplished using a neodymium stir bar magnetically coated with oleic acid-coated cobalt ferrite magnetic nanoparticles (MNPs) as sorbent material, which are detached and dispersed into the solution at high stirring rate. When stirring is stopped, MNPs are magnetically retrieved onto the stir bar, which is subjected to thermal desorption (TD) to…
Fast extraction of cannabinoids in marijuana samples by using hard-cap espresso machines
2018
Abstract A simple, quick and low cost procedure was developed for the extraction of Δ9-tetrahydrocannabinol, cannabidiol, and cannabinol from marijuana samples, based on the use of a hard-cap espresso extraction with 2-propanol. After extraction, cannabinoids were directly determined after appropriate dilution by gas-chromatography-mass spectrometry, reaching a limit of detection from 0.03 to 0.05 mg g−1. Extraction efficiency was evaluated by the comparison of results obtained for seized samples by the proposed method and a reference methodology based on ultrasound-assisted extraction. Moreover, ion mobility was proposed for the rapid and sensitive determination of Δ9-tetrahydrocannabinol …
Detection of 9-Tetrahydrocannabinol and Amphetamine-Type Stimulants in Oral Fluid Using the Rapid Stat Point-of-Collection Drug-Testing Device
2010
The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Delta(9)-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a spec…
Influence of Pigmentation on the Codeine Content of Hair Fibers in Guinea Pigs
1997
Tortoise shell guinea pigs (n = 7) were administered codeine (1 mg/mL codeine-base) in their drinking water for 3 weeks. Black, reddish-brown and white hair was collected separately from each animal before and after treatment. The hair samples were analyzed by GC/MS. The experiment showed positive results for all hair fibers with large individual variability of drug incorporation. Low drug intake resulted in small differences of the drug content in hair fibers different in color, whereas in cases of high drug intake a strong influence of hair pigmentation on the analytical results was observed. The highest drug content was always found in black hair samples, non-pigmented hair showed the lo…