Search results for "Glasse"
showing 10 items of 88 documents
Luminescence of gamma-radiation-induced defects in alpha-quartz
2004
Optical transitions associated with gamma-radiation-induced defects in crystalline a-quartz were investigated by photoluminescence excited by both pulsed synchrotron radiation and steady-state light. After a 10 MGy gamma-dose we observed two emissions at 4.9 eV (ultraviolet band) and 2.7 eV (blue band) excitable in the range of the induced absorption band at 7.6 eV. These two luminescence bands show a different temperature dependence: the ultraviolet band becomes bright below 80 K; the blue band increases below 180 K, but drops down below 80 K. Both emissions decay in a timescale of a few ns under pulsed excitation, however the blue band could also be observed in slow recombination processe…
Suppressive Efficacy by a Commercially Available Blue Lens on PPR in 610 Photosensitive Epilepsy Patients
2006
Purpose Photosensitivity can represent a serious problem in epilepsy patients, also because pharmacologic treatment is often ineffective. Nonpharmacologic treatment using blue sunglasses is effective and safe in controlling photosensitivity, but large series of patients have never been studied. Methods This multicenter study was conducted in 12 epilepsy centers in northern, central, southern, and insular Italy. A commercially available lens, named Z1, obtained in a previous trial, was used to test consecutively enrolled pediatric and adult epilepsy patients with photosensitivity. Only type 4 photosensitivity (photoparoxysmal response, PPR) was considered in the study. A standardized method …
Watch glasses exposed to 6 MV photons and 10 MeV electrons analysed by means of ESR technique
2011
ESR study of proton irradiation response of watch glasses.
2009
Preliminary application of thermoluminescence and single aliquot regeneration method for dose reconstruction in soda lime glass
2013
The research described in this paper shows that the use of the single aliquot regeneration (SAR) method for thermoluminescence (TL) measurements applied to soda lime glasses allows to carry out a retrospective dose evaluation. We have followed a fast and efficient sample preparation procedure which permits measurements without powdering and sieving processes. We have analyzed the TL signal of commercial soda lime watch glass irradiated with 6 Mega Volts (MV) LINAC photons, 10 MeV LINAC electrons and 62 MeV protons. After the initial exposure and following TL reading, the samples are successively irradiated with increasing doses of photons. Therefore, for each sample its calibration curve is…
Photosensitivity of SiO2–Al and SiO2–Na glasses under ArF (193 nm) laser
2009
Abstract Photosensitivity of SiO 2 –Al and SiO 2 –Na glass samples was probed by means of the induced optical absorption and luminescence as well as by electron spin-resonance (ESR) after irradiation with excimer-laser photons (ArF, 193 nm). Permanent visible darkening in the case of SiO 2 –Al and transient, life time about one hour, visible darkening in the case of SiO 2 –Na was found under irradiation at 290 K. No darkening was observed at 80 K for either kind of material. This investigation is dedicated to revealing the electronic processes responsible for photosensitivity at 290 and 80 K. The photosensitivity of both materials is related to impurity defects excited directly in the case …
Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses
2014
Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…
Residual Stresses in Glasses
2013
The history dependence of the glasses formed from flow-melted steady states by a sudden cessation of the shear rate $\dot\gamma$ is studied in colloidal suspensions, by molecular dynamics simulations, and mode-coupling theory. In an ideal glass, stresses relax only partially, leaving behind a finite persistent residual stress. For intermediate times, relaxation curves scale as a function of $\dot\gamma t$, even though no flow is present. The macroscopic stress evolution is connected to a length scale of residual liquefaction displayed by microscopic mean-squared displacements. The theory describes this history dependence of glasses sharing the same thermodynamic state variables, but differi…
In situobservation of the generation and annealing kinetics of E ′ centres induced in amorphous SiO2by 4.7 eV laser irradiation
2011
The kinetics of E' centers induced in silica by 4.7eV laser irradiation was investigated observing in situ their optical absorption band at 5.8 eV. After exposure the defects decay due to reaction with diffusing molecular hydrogen of radiolytic origin. Hydrogen-related annealing is active also during exposure and competes with the photo-induced generation of the centers until a saturation is reached. The concentrations of E' and H2 at saturation are proportional, so indicating that the UV-induced generation processes of the two species are correlated. These results are consistent with a model in which E' and hydrogen are generated from a common precursor Si-H.
Stereoacuity with balanced presbyopic contact lenses.
2010
Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…