Search results for "Glasse"

showing 10 items of 88 documents

Luminescence of gamma-radiation-induced defects in alpha-quartz

2004

Optical transitions associated with gamma-radiation-induced defects in crystalline a-quartz were investigated by photoluminescence excited by both pulsed synchrotron radiation and steady-state light. After a 10 MGy gamma-dose we observed two emissions at 4.9 eV (ultraviolet band) and 2.7 eV (blue band) excitable in the range of the induced absorption band at 7.6 eV. These two luminescence bands show a different temperature dependence: the ultraviolet band becomes bright below 80 K; the blue band increases below 180 K, but drops down below 80 K. Both emissions decay in a timescale of a few ns under pulsed excitation, however the blue band could also be observed in slow recombination processe…

ELECTRON-PARAMAGNETIC-RESONANCEAMORPHOUS-SILICON DIOXIDEOPTICAL-ABSORPTIONGLASSESSYNTHETIC SILICAPHOTOLUMINESCENCESIO2BANDOXYGEN-DEFICIENT CENTERSIRRADIATION
researchProduct

Suppressive Efficacy by a Commercially Available Blue Lens on PPR in 610 Photosensitive Epilepsy Patients

2006

Purpose Photosensitivity can represent a serious problem in epilepsy patients, also because pharmacologic treatment is often ineffective. Nonpharmacologic treatment using blue sunglasses is effective and safe in controlling photosensitivity, but large series of patients have never been studied. Methods This multicenter study was conducted in 12 epilepsy centers in northern, central, southern, and insular Italy. A commercially available lens, named Z1, obtained in a previous trial, was used to test consecutively enrolled pediatric and adult epilepsy patients with photosensitivity. Only type 4 photosensitivity (photoparoxysmal response, PPR) was considered in the study. A standardized method …

EPILEPSY-PHOTOSENSITIVE-BLUE GLASSES-NONPHARMACOLOGICAdultMalemedicine.medical_specialtyAdolescentEpilepsy ReflexPharmacological treatmentCentral nervous system diseaseEpilepsyPhotosensitive epilepsyInternal medicineFemale patientmedicineHumansPractice Patterns Physicians'ChildAgedbusiness.industryVideotape RecordingLarge seriesElectroencephalographyMiddle Agedmedicine.diseaseTREATMENT-PHOTOPAROXYSMAL RESPONSE-PPRSurgeryClinical trialTreatment OutcomeItalyNeurologyMulticenter studyChild PreschoolAnticonvulsantsFemaleNeurology (clinical)PHOTOSENSITIVEEye Protective DevicesbusinessColor PerceptionPhotic StimulationEpilepsia
researchProduct

Watch glasses exposed to 6 MV photons and 10 MeV electrons analysed by means of ESR technique

2011

ESR dosimetry watch glasses electrons photonsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

ESR study of proton irradiation response of watch glasses.

2009

ESR dosimetry watch glassesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Preliminary application of thermoluminescence and single aliquot regeneration method for dose reconstruction in soda lime glass

2013

The research described in this paper shows that the use of the single aliquot regeneration (SAR) method for thermoluminescence (TL) measurements applied to soda lime glasses allows to carry out a retrospective dose evaluation. We have followed a fast and efficient sample preparation procedure which permits measurements without powdering and sieving processes. We have analyzed the TL signal of commercial soda lime watch glass irradiated with 6 Mega Volts (MV) LINAC photons, 10 MeV LINAC electrons and 62 MeV protons. After the initial exposure and following TL reading, the samples are successively irradiated with increasing doses of photons. Therefore, for each sample its calibration curve is…

Electron beamSoda-lime glassNuclear and High Energy PhysicsMaterials scienceThermoluminescenceCalibration curveRadiochemistryMineralogyThermoluminescenceProton beamchemistry.chemical_compoundSoda limechemistrySoda lime watch glasseCathode rayPhoton beamSample preparationIrradiationSingle aliquot regeneration methodWatch glassInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Photosensitivity of SiO2–Al and SiO2–Na glasses under ArF (193 nm) laser

2009

Abstract Photosensitivity of SiO 2 –Al and SiO 2 –Na glass samples was probed by means of the induced optical absorption and luminescence as well as by electron spin-resonance (ESR) after irradiation with excimer-laser photons (ArF, 193 nm). Permanent visible darkening in the case of SiO 2 –Al and transient, life time about one hour, visible darkening in the case of SiO 2 –Na was found under irradiation at 290 K. No darkening was observed at 80 K for either kind of material. This investigation is dedicated to revealing the electronic processes responsible for photosensitivity at 290 and 80 K. The photosensitivity of both materials is related to impurity defects excited directly in the case …

Electron mobilityPhotoluminescenceChemistryDopingAnalytical chemistryCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsPhotosensitivityImpurityMaterials ChemistryCeramics and CompositesIrradiationRadiation effects Glasses Laser–matter interactions Optical spectroscopy Defects Optical properties Absorption Lasers Luminescence Photoinduced effects Time resolved measurements Oxide glasses Alkali silicates Aluminosilicates Silica Silicates Radiation Electron spin resonanceSpectroscopyLuminescence
researchProduct

Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses

2014

Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…

In line holographyComputer scienceHolographyNormal DistributionBiomedical EngineeringHolographyDiagnostic Techniques OphthalmologicalEngravinglaw.inventionBiomaterialsAutomationImaging Three-DimensionalOpticslawMaterials TestingImage Processing Computer-AssistedHumansComputer visionLensesProgressive addition lensesWavefrontLaser engravingbusiness.industryLasersReproducibility of ResultsEquipment DesignAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisualizationEyeglassesvisual_artCalibrationvisual_art.visual_art_mediumArtificial intelligencebusinessAlgorithmsDigital holographyJournal of Biomedical Optics
researchProduct

Residual Stresses in Glasses

2013

The history dependence of the glasses formed from flow-melted steady states by a sudden cessation of the shear rate $\dot\gamma$ is studied in colloidal suspensions, by molecular dynamics simulations, and mode-coupling theory. In an ideal glass, stresses relax only partially, leaving behind a finite persistent residual stress. For intermediate times, relaxation curves scale as a function of $\dot\gamma t$, even though no flow is present. The macroscopic stress evolution is connected to a length scale of residual liquefaction displayed by microscopic mean-squared displacements. The theory describes this history dependence of glasses sharing the same thermodynamic state variables, but differi…

Length scaleThermodynamic stateFOS: Physical sciencesGeneral Physics and Astronomy02 engineering and technologyCondensed Matter - Soft Condensed Matterglasses01 natural sciencesMolecular dynamicsResidual stress0103 physical sciencesddc:530Ideal (ring theory)010306 general physicsPhysicsCondensed Matter - Materials ScienceCondensed matter physicsMaterials Science (cond-mat.mtrl-sci)021001 nanoscience & nanotechnologyShear rateCondensed Matter::Soft Condensed MatterFlow (mathematics)residual stressesSoft Condensed Matter (cond-mat.soft)Relaxation (physics)rheology0210 nano-technologyRheology Glasses Residual Stresses Mode Coupling Theory
researchProduct

In situobservation of the generation and annealing kinetics of E ′ centres induced in amorphous SiO2by 4.7 eV laser irradiation

2011

The kinetics of E' centers induced in silica by 4.7eV laser irradiation was investigated observing in situ their optical absorption band at 5.8 eV. After exposure the defects decay due to reaction with diffusing molecular hydrogen of radiolytic origin. Hydrogen-related annealing is active also during exposure and competes with the photo-induced generation of the centers until a saturation is reached. The concentrations of E' and H2 at saturation are proportional, so indicating that the UV-induced generation processes of the two species are correlated. These results are consistent with a model in which E' and hydrogen are generated from a common precursor Si-H.

MECHANISMMaterials scienceHydrogenAnnealing (metallurgy)KineticsHIGH-PURITY SILICAFOS: Physical scienceschemistry.chemical_elementPhotochemistrylaw.inventionDEFECT FORMATIONTRANSIENT ABSORPTIONlawGeneral Materials ScienceIrradiationINDUCED COLOR-CENTERSCondensed Matter - Materials ScienceMaterials Science (cond-mat.mtrl-sci)Condensed Matter PhysicsLaserDIFFUSIONAmorphous solidchemistryAbsorption bandMOLECULAR-HYDROGENGLASSESLUMINESCENCERadiolysisEXCIMER-LASERJournal of Physics: Condensed Matter
researchProduct

Stereoacuity with balanced presbyopic contact lenses.

2010

Our aim was to evaluate near stereoacuity with the balanced Proclear Multifocal simultaneous vision contact lens. Twenty-five presbyopic subjects were fitted binocularly with the Proclear Multifocal contact lens and with distance contact lenses combined with reading spectacles, which served as controls. After one month, stereoacuity was measured using the vectographic Titmus and Random dot stereotests and the Howard-Dolman (HD) apparatus under photopic conditions (85 cd/m(2) ) at 40 cm. Binocular high-contrast visual acuities (BHCVA) at distance and near were examined. For the multifocal group, mean stereoacuity with the Howard-Dolman method was 22.40 ± 8.23 seconds of arc. Using the Titmus…

MaleVisual acuitygenetic structuresContact LensesVisual AcuityContrast SensitivitymedicineHumansVision testDepth PerceptionVision BinocularVision TestsPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesStereoscopic acuityOphthalmologyEyeglassesReadingOftalmologíaOptometryFemalemedicine.symptomDepth perceptionPsychologyBinocular visionOptometryClinicalexperimental optometry
researchProduct