Search results for "Heart Ventricles"

showing 10 items of 162 documents

No evidence of adverse cardiac remodeling in former elite endurance athletes

2016

Background: The impact of high exercise loads on a previously healthy heart remains controversial. We examined the consequences of decades of strenuous endurance exercise at the highest competition level on heart dimensions and volumes as well as on serum biomarkers of cardiac fibrosis/remodeling. Methods and results: We compared echocardiographic measurements and serum biomarkers of cardiac fibrosis/remodeling [troponin I, galectin-3, matrix metallopeptidase-2 and -9, N-terminal pro-brain natriuretic peptide, carboxy-terminal propeptide of type I procollagen, and soluble suppressor of tumorigenicity-2 (sST-2)/interleukin(IL)-1R4] in 53 male athletes [11 former professional ('elite') and 42…

MaleCardiac fibrosis030204 cardiovascular system & hematology0302 clinical medicineReference ValuesTroponin INatriuretic peptideVentricular FunctionAtletismo - Aspectos fisiológicosBody surface areaVentricular RemodelingCorazónmedicine.diagnostic_testbiologyOrgan SizeMiddle AgedEndurance exercisePathophysiologyEchocardiographyHeart Function TestsCardiologyCardiology and Cardiovascular MedicineSportsAdultmedicine.medical_specialtymedicine.drug_classHeart VentriclesMagnetic Resonance Imaging CineTime03 medical and health sciencesCardiac magnetic resonance imagingEndurance trainingAtletaInternal medicinemedicineHumansExerciseCardiac remodelingSistema cardiovascularCardiac fibrosisbusiness.industryAthletes030229 sport sciencesmedicine.diseasebiology.organism_classificationEndocrinologyAthletesPhysical FitnessPhysical EndurancebusinessInternational Journal of Cardiology
researchProduct

Isolated RV diverticulum: diagnosis by cardiac magnetic resonance and 3D TEE

2014

A 16-year-old male was referred to our hospital because of exertional chest pain. There was no personal or family history of any cardiovascular disease. Findings on physical examination and vital signs were normal. An ECG showed a right bundle superoanterior zonal block pattern with low potentials in frontal plane and intraventricular conduction delay (QRS Complex 120 msg) with pseudo-epsilon wave in V1 …

MaleChest Painmedicine.medical_specialtyAdolescentHeart DiseasesHeart VentriclesEchocardiography Three-DimensionalVital signsMagnetic Resonance Imaging CinePhysical examinationQRS complexRare DiseasesInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesFamily historyMonitoring Physiologicmedicine.diagnostic_testbusiness.industryGeneral Medicinemedicine.diseaseDiverticulumExertional chest painCoronal planeCardiologyRadiologyCardiology and Cardiovascular MedicinebusinessCardiac magnetic resonanceEchocardiography TransesophagealDiverticulumEuropean Heart Journal - Cardiovascular Imaging
researchProduct

GAS CHROMATOGRAPHIC ESTIMATION OF ACETYLCHOLINE IN THE RABBIT HEART USING A NITROGEN SELECTIVE DETECTOR

1973

The distribution of ACh in the rabbit heart was investigated by a modified gas chromatographic estimation method. ACh was extracted with perchloric acid, precipitated as reineckate and demethylated with sodium benzenethiolate. The tertiary amines derived from ACh and other choline esters were concentrated by a microdistillation procedure. Gas chromatography was performed using a nitrogen selective detector. In the range of concentrations between 0.4 and 2.5 nmol ACh per tissue sample the coefficient of variation was 5.2 per cent. The recovery of ACh added to heart extracts was 101 per cent. Evidence for the identity of the choline ester isolated from rabbit hearts and authentic ACh was obta…

MaleChromatography GasHeart VentriclesCoefficient of variationSodiumchemistry.chemical_elementBlood PressureBiochemistryCholineCellular and Molecular Neurosciencechemistry.chemical_compoundMethodsmedicineAnimalsBioassayCholineHeart AtriaPerchloric acidButyrylcholineChromatographyChemistryMyocardiumAcetylcholineRatsButyratesBiological AssayFemaleRabbitsGas chromatographyPropionatesAcetylcholinemedicine.drugJournal of Neurochemistry
researchProduct

Downregulation and Nuclear Relocation of MLP During the Progression of Right Ventricular Hypertrophy Induced by Chronic Pressure Overload

2000

Abstract The cardiac LIM domain protein MLP plays a crucial role in the architecture and mechanical function of cardiac myocytes. Mice lacking the MLP gene develop cardiac hypertrophy, dilated cardiopathy and heart failure. We investigated whether downregulation of MLP is induced by pressure overload and contributes to the physiopathology of cardiac hypertrophy and failure. We studied this mechanism in rat right ventricles submitted to pulmonary arterial hypertension, because it is known that this ventricle is very vulnerable to the deleterious effects of pressure overload. During the progression of cardiac hypertrophy to failure over a 31 days period there was a dramatic decrease by 50% of…

MaleCytoplasmmedicine.medical_specialtyTime FactorsTranscription GeneticHeart VentriclesDown-RegulationMuscle ProteinsCardiomegalyCytosolMyofibrilsDownregulation and upregulationRight ventricular hypertrophyInternal medicinePressureAnimalsVentricular FunctionMedicineMyocyteRNA MessengerRats WistarLungMolecular BiologyCell NucleusHomeodomain ProteinsPressure overloadReverse Transcriptase Polymerase Chain Reactionbusiness.industryMyocardiumLIM Domain Proteinsmedicine.diseaseImmunohistochemistryPulmonary hypertensionRatsMicroscopy Electronmedicine.anatomical_structureVentricleHeart failureCardiologyCardiology and Cardiovascular MedicinebusinessMyofibrilJournal of Molecular and Cellular Cardiology
researchProduct

Effect of aging and hypertension on β-myosin heavy chain in heart of spontaneously hypertensive rats

2001

During aging rat myocardium undergoes structural changes characterized by a shift in the synthesis of myosin heavy chain (MHC) from V1 isoform, composed of two alpha-MHC, to V3 isoform, composed of two beta-MHC. In rat, besides ageing, cardiac hypertrophy as adaptive response to a superimposed pressure load (such as hypertension) is characterized by predominance of V3 myosin isoform. The aim of our study was to evaluate the expression of beta-MHC in right (RV) and left (LV) ventricles of spontaneously hypertensive rats (SHRs), a well defined animal model of hypertension, in relation to aging. We used very young (8-week old) and young (15-week old) SHRs and age-matched normotensive Harlan Sp…

MaleGene isoformSenescenceAgingmedicine.medical_specialtyHeart VentriclesBlotting WesternAnimal modelRats Inbred SHRInternal medicineMyosinGeneticsmedicineAnimalsProtein Isoformscardiovascular diseasesMyosin Heavy ChainsOncogenebusiness.industryGeneral MedicineMolecular medicineRatsEndocrinologyApoptosisAgeingHypertensionbusinessInternational Journal of Molecular Medicine
researchProduct

Expression of thyroid hormone receptor isoforms in the hypertrophic heart of spontaneously hypertensive rats

2001

Thyroid hormones (THs) enhance MHC alpha gene- and repress MHC beta gene-transcription in the heart, by interacting with specific nuclear receptors (TRs), that bind to regulatory sequences localized upstream of basal promoter of myosin heavy chain (MHC) genes. The overall effects of THs include an increase in V1- and a decrease in V3-myosin isozyme concentration in the heart. Myosin V1 contains two MHC alpha chains and has a higher ATPase activity than V3 isoform, which contains two beta chains. Previous studies on papillary muscles of spontaneously hypertensive rats (SHRs) showed that heart hypertrophy is accompanied by a shift from alpha to beta MHC accumulation. The present study was aim…

MaleGene isoformmedicine.medical_specialtyHeart VentriclesBlotting WesternAlpha (ethology)CardiomegalyBiologyIsozymeRats Sprague-DawleyRats Inbred SHRInternal medicineMyosinGeneticsmedicineAnimalsProtein IsoformsReceptorReceptors Thyroid HormoneThyroid hormone receptorMyosin Heavy ChainsGeneral MedicineRatsBlotEndocrinologyNuclear receptorHypertensionModels AnimalInternational Journal of Molecular Medicine
researchProduct

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

2017

Background. Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). Methods and results. Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correla…

MaleIntraclass correlationHeart Ventricles030204 cardiovascular system & hematologyleft ventricular masscardiac magnetic resonance030218 nuclear medicine & medical imagingHeart NeoplasmsLeft ventricular mass03 medical and health sciencesMyocardial perfusion imagingchemistry.chemical_compound0302 clinical medicinePredictive Value of TestsNuclear Medicine and ImagingHumansMedicineRadiology Nuclear Medicine and imagingAgedRetrospective StudiesAged 80 and overTomography Emission-Computed Single-Photonmedicine.diagnostic_testbusiness.industryLimits of agreementMyocardial Perfusion ImagingReproducibility of ResultsCadmium-Zinc-Telluride Æ cardiac magnetic resonance Æ SPECT Æ left ventricular massMiddle AgedMagnetic Resonance ImagingCadmium zinc tellurideZincchemistryCadmium-Zinc-Telluride; cardiac magnetic resonance; left ventricular mass; SPECT; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineSPECTCadmium-Zinc-TellurideFemaleTelluriumRadiologyCardiology and Cardiovascular MedicineNuclear medicinebusinessCardiac magnetic resonanceEmission computed tomographyCadmiumJournal of Nuclear Cardiology
researchProduct

Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study

2017

International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) measurements of left ventricular (LV) strain from a large group of healthy volunteers accounting for age and gender. Methods and results - A total of 549 (mean age: 45.6 ± 13.3 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. 2DE data sets have been analysed with a vendor-independent software package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire the data sets. The lowest expected values of LV strains and twist calculated as ± 1.96 standard deviations from the mean…

MaleLongitudinal straindeformation imaging[SDV]Life Sciences [q-bio]Sex Factor030204 cardiovascular system & hematologyStandard deviationVentricular Function LeftHeart Ventricle2D echocardiography0302 clinical medicineReference ValuesNuclear Medicine and ImagingImage Processing Computer-AssistedMedicineCircumferential strainAge FactorReference Value030212 general & internal medicineMultivariate Analysi2D echocardiography; Adult echocardiography; Deformation imaging; Reference values; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineObserver VariationStrain (chemistry)Age FactorsGeneral MedicineMiddle AgedHealthy VolunteerHealthy VolunteersEuropeHomogeneousEchocardiographyRadiology Nuclear Medicine and imagingCardiologyLinear ModelFemaleRadiologyCardiology and Cardiovascular MedicineRadial stressHumanAdultmedicine.medical_specialtyadult echocardiographyHeart Ventricles03 medical and health sciencesSex FactorsInternal medicineHumansRadiology Nuclear Medicine and imaging2d strainbusiness.industryMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREReference valuesMultivariate AnalysisLinear Modelsbusiness
researchProduct

Echocardiographic reference ranges for normal cardiac chamber size: Results from the NORRE study

2014

AimsAvailability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following chamber quantitation protocols approved by the European Association of Cardiovascular Imaging.MethodsA total of 734 (mean age: 45.8 ± 13.3 years) healthy volunteers (320 men and 414 women) were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORR…

MaleLower blood pressureSex FactorHeart VentricleCohort StudiesChamber size and function; Reference values; Two-dimensional echocardiography; Cardiology and Cardiovascular Medicine; Radiology Nuclear Medicine and Imaging; Medicine (all)Nuclear Medicine and ImagingAge FactorReference ValueYoung adultBody surface areaObserver VariationMedicine (all)Age FactorsGeneral MedicineStroke volumeMiddle AgedEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicineRadiologyHumanCohort studyAdultmedicine.medical_specialtyHeart VentriclesReproducibility of ResultChamber size and functionRisk AssessmentReference valuesYoung AdultSex FactorsTwo-dimensional echocardiographyInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingHeart AtriaAgedbusiness.industryReproducibility of ResultsMean ageStroke VolumeMED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREOriginal ArticlesCardiac chamberReference valuesCohort Studiebusiness
researchProduct

Is there a right place to pace the right ventricle? Evaluation of apical and septal positions in a pacemaker population: Study protocol for a prospec…

2014

Abstract Introduction The main objective of research in pacemaker therapy has been to provide the best physiologic way to pace the heart. Despite the good results provided by right ventricular pacing minimization and by biventricular pacing in specific subsets of heart failure patients, these options present many limitations for standard pacemaker recipients. In these patients, pacing the right ventricle at alternative sites could result in a lower degree of left intraventricular dyssynchrony. Despite the lack of strong evidence and the difficulty in placing and accurately classifying the final lead position, pacing at alternative right ventricular sites seems to have become a standard proc…

MalePacemaker Artificialmedicine.medical_specialtyHeart Ventriclesmedicine.medical_treatmentPopulationCardiac resynchronization therapySTUDY DESIGNSeverity of Illness IndexInternal medicinePACEMAKERmedicineHumansSingle-Blind MethodPharmacology (medical)Prospective StudieseducationVentricular dyssynchronyHeart Failureeducation.field_of_studyEjection fractionDYSSYNCHRONYbusiness.industryGeneral Medicinemedicine.diseaseImplantable cardioverter-defibrillatorHospitalizationmedicine.anatomical_structureEchocardiographyResearch DesignVentriclePACEMAKER; STUDY DESIGN; DYSSYNCHRONYHeart failureQuality of LifeCardiologyEnd-diastolic volumeFemalebusinessContemporary Clinical Trials
researchProduct