Search results for "Imaging phantom"

showing 10 items of 127 documents

Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography

2013

Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…

MaleUrologyRadiographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomBody Mass IndexRadiation MonitoringRecurrenceReference ValuesHumansMedicineObesityDosimeterPhantoms Imagingbusiness.industryEquivalent doseRadiation doseModels Theoreticalequipment and suppliesBody BurdenTomographyTomography X-Ray ComputedbusinessNuclear medicineBody mass indexJournal of Urology
researchProduct

Fistulous-type vein of Galen malformation phantom model for endovascular training and research.

2016

IntroductionVein of Galen malformation (VGM), a high-flow intracranial arteriovenous shunt, is among the most severe neurovascular diseases in childhood. In many cases untreated children die or survive only severely disabled. Endovascular embolization is the preferred treatment.ObjectiveTo develop a simple fistulous-type VGM phantom model for teaching and training of different endovascular treatment methods and to investigate new treatment options and devices.MethodsAn experimental in vitro pulsatile phantom model was developed imitating a high-flow fistulous-type VGM, which is typical, especially in the neonatal phase. Pressure measurements at different arterial sites were performed before…

Malemedicine.medical_specialtyBiomedical Researchmedicine.medical_treatmentHemodynamicsImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicineFluoroscopyHumansEmbolizationChildmedicine.diagnostic_testbusiness.industryPhantoms ImagingVascular malformationEndovascular ProceduresArteriovenous malformationGeneral MedicineNeurovascular bundlemedicine.diseaseShunt (medical)Child PreschoolArteriovenous FistulaVein of Galen MalformationsSurgeryFemaleNeurology (clinical)Radiologybusiness030217 neurology & neurosurgeryJournal of neurointerventional surgery
researchProduct

Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (C…

2017

The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute an…

Malemedicine.medical_specialtyCone beam computed tomographyEpidemiologyHealth Toxicology and MutagenesisCoefficient of variationRadiation DosageImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciencesRadiation Protection0302 clinical medicinefashionSkin Physiological PhenomenaRadiography DentalHumansMedicineRadiology Nuclear Medicine and imagingReproducibilityDosimeterPhantoms Imagingbusiness.industryThyroidAbsorption RadiationEquipment Design030206 dentistryCone-Beam Computed TomographyRadiation ExposureEquipment Failure Analysismedicine.anatomical_structurefashion.garmentLead apronFemaleBody regionRadiologybusinessHealth Physics
researchProduct

Digital Tomosynthesis: A New Technique for Imaging Nephrolithiasis. Specific Organ Doses and Effective Doses Compared With Renal Stone Protocol Nonco…

2014

Objective To determine organ-specific doses (ODs) and effective dose (ED) for digital tomosynthesis (DT) and compare it with our institutional renal stone protocol noncontrast computed tomography (NCCT). Methods A validated anthropomorphic male phantom was placed supine on a digital GE Definium 8000 radiological scanner. Thermoluminescent dosimeters were placed in 256 locations and used to measure OD. A routine DT study was performed consisting of 2 scout images and 1 tomographic sweep in a 14.2-degree arc over the phantom. Software is used to recreate a series of coronal images from the sweep. ODs were determined as the sum of the doses for the study. Equivalent doses were calculated by mu…

Malemedicine.medical_specialtyRenal stoneSupine positionDosimetermedicine.diagnostic_testPhantoms Imagingbusiness.industryUrologyComputed tomographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomTomosynthesisRadiographic Image EnhancementmedicineHumansTomographyRadiologyTomography X-Ray ComputedNuclear medicinebusinessUrology
researchProduct

Short-Term Precision Error of Bone Strain Index, a New DXA-Based Finite Element Analysis Software for Assessing Hip Strength

2020

Abstract Bone Strain Index (BSI) is a new finite element analysis tool applied to hip dual energy X-ray absorptiometry scans. The aim of this study was to assess the short-term precision error of BSI on the proximal femur, both on a phantom and patients. The International Society for Clinical Densitometry guidelines were followed for short-term precision error assessment. Dual energy X-ray absorptiometry measurements were performed on an anthropomorphic femur phantom that was scanned twice for 30 times, for a total of 60 scans. For the in vivo part, 30 subjects were scanned twice. BSI precision error was compared to that of bone mineral density (BMD). Both for the phantom and the in vivo st…

Malemusculoskeletal diseases0301 basic medicineEndocrinology Diabetes and MetabolismCoefficient of variationFinite Element Analysis030209 endocrinology & metabolismPatient PositioningImaging phantom03 medical and health sciencesAbsorptiometry Photon0302 clinical medicineBone DensitymedicineHumansRadiology Nuclear Medicine and imagingOrthopedics and Sports MedicineFemurFemurDual-energy X-ray absorptiometryAgedFemoral neckBone mineralReproducibilitymedicine.diagnostic_testPhantoms Imagingbusiness.industryReproducibility of Resultsbacterial infections and mycosesmedicine.anatomical_structureOsteoporosisFemale030101 anatomy & morphologyDensitometrybusinessNuclear medicinehuman activitiesSoftwareJournal of Clinical Densitometry
researchProduct

Photo-acoustic excitation and optical detection of fundamental flexural guided wave in coated bone phantoms.

2013

Abstract Photo-acoustic (PA) imaging was combined with skeletal quantitative ultrasound (QUS) for assessment of human long bones. This approach permitted low-frequency excitation and detection of ultrasound so as to efficiently receive the thickness-sensitive fundamental flexural guided wave (FFGW) through a coating of soft tissue. The method was tested on seven axisymmetric bone phantoms, whose 1- to 5-mm wall thickness and 16-mm diameter mimicked those of the human radius. Phantoms were made of a composite material and coated with a 2.5- to 7.5-mm layer of soft material that mimicked soft tissue. Ultrasound was excited with a pulsed Nd:YAG laser at 1064-nm wavelength and received on the s…

Materials scienceAcoustics and UltrasonicsBiophysics02 engineering and technology01 natural sciencesSensitivity and SpecificityImaging phantomBone and Bones010309 opticsOpticsLamb wavesFlexural strengthCoated Materials BiocompatibleBone Density0103 physical sciencesmedicineHumansRadiology Nuclear Medicine and imagingGuided wave testingRadiological and Ultrasound Technologyta114business.industryPhantoms ImagingLasersUltrasoundReproducibility of ResultsEquipment Design021001 nanoscience & nanotechnologyEquipment Failure Analysismedicine.anatomical_structureSoundAcoustic StimulationElasticity Imaging TechniquesUltrasonic sensorCortical bonePhase velocity0210 nano-technologybusinessPhotic StimulationDensitometryUltrasound in medicinebiology
researchProduct

Thickness sensitivity of ultrasound velocity in long bone phantoms

2004

One approach to bone disease diagnosis such as osteoporosis is to measure the velocity of ultrasound propagating axially along long bones. In this study, the variation in velocity as a function of radial position was assessed using two polyvinyl chloride (PVC) bone phantoms with cross-sectional geometry similar to the human tibia but differing in medullary cavity diameter. Two ultrasonometers were used: these were a commercial device operating at a relatively high frequency (HF) of 1.25 MHz and a prototype low frequency (LF) device operating at approximately 200 kHz. The LF measurements showed a larger variation with radial position, with changes in velocity of up to 20% occurring around th…

Materials scienceAcoustics and UltrasonicsBone diseaseMedullary cavityLong boneBiophysicsLow frequencyBone and BonesImaging phantommedicineHumansUltrasonicsRadiology Nuclear Medicine and imagingTibiaPolyvinyl ChlorideUltrasonographyTibiaRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industryUltrasoundAnatomymedicine.diseasemedicine.anatomical_structureOsteoporosisbusinessAxial symmetryBiomedical engineeringUltrasound in Medicine & Biology
researchProduct

Measuring guided waves in long bones: Modeling and experiments in free and immersed plates

2005

Guided waves, consistent with the A0 Lamb mode, have previously been observed in bone phantoms and human long bones. Reported velocity measurements relied on line fitting of the observed wave fronts. Such an approach has limited ability to assess dispersion and is affected by interference by other wave modes. For a more robust identification of modes and determination of phase velocities, signal processing techniques using the fast Fourier transform (FFT) were investigated. The limitations of FFT because of spatial resolution were addressed to improve the precision of the measured modes. An inversion scheme was developed for determining the plate thickness from the measured velocity. Experi…

Materials scienceAcoustics and UltrasonicsLine fittingAcousticsFast Fourier transformBiophysicsModels BiologicalBone and BonesImaging phantomsymbols.namesakeOpticsmedicineHumansRadiology Nuclear Medicine and imagingImage resolutionUltrasonographySignal processingFourier AnalysisRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industrySignal Processing Computer-AssistedAcousticsmedicine.anatomical_structureFourier analysissymbolsGroup velocityCortical bonebusinessUltrasound in Medicine & Biology
researchProduct

Diagnostic Performance and Radiation Dose of the EOS System to Image Enchondromatosis: A Phantom Study

2020

Background: Radiation doses and capability of EOS, conventional radiography (CR), and computed tomography (CT) to detect and measure enchondromas in a dedicated five-year-old anthropomorphic phantom were compared. Methods: To simulate enchondromas, minced pieces of chicken bone and cartilage were packed in conventional kitchen plastic foil to create ovoidal/rounded masses and randomly hung on the phantom. The phantom was imaged five times with CR, CT, and EOS, each time changing the number and position of inserts. All images were reviewed by a senior radiologist and a radiology resident. Results: EOS and CR detected all inserts in 4/5 cases (80%), while in one case 1/17 inserts was not seen…

Materials scienceComputed tomographylcsh:TechnologyImaging phantom030218 nuclear medicine & medical imagingenchondromalcsh:Chemistry03 medical and health sciences0302 clinical medicineEnchondromatosismedicineGeneral Materials Sciencelcsh:QH301-705.5InstrumentationFluid Flow and Transfer ProcessesReproducibilitymedicine.diagnostic_testlcsh:Tbusiness.industryEOSProcess Chemistry and TechnologyRadiation doseGeneral Engineeringcomputed tomographyRepeatabilityphantommedicine.diseaseconventional radiographylcsh:QC1-999Computer Science ApplicationsConventional radiographylcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Anthropomorphic phantomlcsh:Engineering (General). Civil engineering (General)Nuclear medicinebusinessradiation doselcsh:Physics030217 neurology & neurosurgeryApplied Sciences
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct