Experimental comparison between direct and indirect measurement techniques for the characterization of Linear Induction Motors

1997

Abstract An experimental comparison between direct and indirect measurement techniques for the on-line characterization of Linear Induction Motors (LIMs) is presented. Indirect measurements are based on a mathematical model of the motors. Direct measurements are carried out by means of traditional instruments and a smart sensor, located on the LIM and linked to the controller by the power supply line. Both a synthetic description of the LIM model and the sensor architecture are reported. The experimental results, achieved by applying different feeding strategy, are discussed.

Electric motorEngineeringbusiness.industryApplied MathematicsControl engineeringLinear motorCondensed Matter PhysicsCarrier currentPower (physics)Intelligent sensorControl theoryLinear induction motorLine (geometry)Electronic engineeringElectrical and Electronic EngineeringbusinessInstrumentation
researchProduct

Applying Spring Security Framework with KeyCloak-Based OAuth2 to Protect Microservice Architecture APIs: A Case Study

2022

In this study, we implemented an integrated security solution with Spring Security and Keycloak open-access platform (SSK) to secure data collection and exchange over microservice architecture application programming interfaces (APIs). The adopted solution implemented the following security features: open authorization, multi-factor authentication, identity brokering, and user management to safeguard microservice APIs. Then, we extended the security solution with a virtual private network (VPN), Blowfish and crypt (Bcrypt) hash, encryption method, API key, network firewall, and secure socket layer (SSL) to build up a digital infrastructure. To accomplish and describe the adopted SSK solutio…

Electrical and Electronic EngineeringAPI; REST; spring-boot; Keycloak; authentication; authorization; encryption; external attacksVDP::Teknologi: 500::Informasjons- og kommunikasjonsteknologi: 550BiochemistryInstrumentationComputer SecuritySoftwareAtomic and Molecular Physics and OpticsAnalytical ChemistrySensors
researchProduct

Detection of Ventricular Fibrillation Using the Image from Time-Frequency Representation and Combined Classifiers without Feature Extraction

2018

Due the fact that the required therapy to treat Ventricular Fibrillation (V F) is aggressive (electric shock), the lack of a proper detection and recovering therapy could cause serious injuries to the patient or trigger a ventricular fibrillation, or even death. This work describes the development of an automatic diagnostic system for the detection of the occurrence of V F in real time by means of the time-frequency representation (T F R) image of the ECG. The main novelties are the use of the T F R image as input for a classification process, as well as the use of combined classifiers. The feature extraction stage is eliminated and, together with the use of specialized binary classifiers, …

ElectrodiagnòsticECG electrocardiogram signalsComputer science0206 medical engineeringFeature extraction02 engineering and technologycombined classification algorithmslcsh:TechnologyImage (mathematics)lcsh:ChemistryTime–frequency representationimage analysisvoting majority method classifiersnon-stationary signalstime-frequency representation0202 electrical engineering electronic engineering information engineeringmedicineGeneral Materials ScienceInstrumentationlcsh:QH301-705.5Fluid Flow and Transfer Processesbusiness.industrybiomedical systemslcsh:TProcess Chemistry and TechnologyGeneral EngineeringPattern recognitionmedicine.disease020601 biomedical engineeringlcsh:QC1-999Computer Science ApplicationsTheoryofComputation_MATHEMATICALLOGICANDFORMALLANGUAGESlcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040Ventricular fibrillationEnginyeria biomèdica020201 artificial intelligence & image processingArtificial intelligencebusinesslcsh:Engineering (General). Civil engineering (General)hierarchical classifiersImatges Processament Tècniques digitalslcsh:PhysicsApplied Sciences
researchProduct

Real-Time Localization of Epileptogenic Foci EEG Signals: An FPGA-Based Implementation

2020

The epileptogenic focus is a brain area that may be surgically removed to control of epileptic seizures. Locating it is an essential and crucial step prior to the surgical treatment. However, given the difficulty of determining the localization of this brain region responsible of the initial seizure discharge, many works have proposed machine learning methods for the automatic classification of focal and non-focal electroencephalographic (EEG) signals. These works use automatic classification as an analysis tool for helping neurosurgeons to identify focal areas off-line, out of surgery, during the processing of the huge amount of information collected during several days of patient monitori…

ElectrodiagnòsticRemote patient monitoringComputer science02 engineering and technologyElectroencephalographylcsh:Technologylcsh:Chemistryepileptogenic focus03 medical and health sciences0302 clinical medicineClassifier (linguistics)0202 electrical engineering electronic engineering information engineeringmedicineGeneral Materials ScienceEpilepsy surgeryLatency (engineering)Field-programmable gate arrayInstrumentationThroughput (business)lcsh:QH301-705.5FPGAFluid Flow and Transfer Processesmedicine.diagnostic_testbusiness.industrylcsh:TProcess Chemistry and Technologyreal-time implementationepileptic eeg signal classificationGeneral EngineeringProcess (computing)Pattern recognitionelectroencephalogramlcsh:QC1-999Computer Science Applicationsfpgalcsh:Biology (General)lcsh:QD1-999lcsh:TA1-2040epileptic EEG signal classificationepilepsy020201 artificial intelligence & image processingEnginyeria biomèdicaArtificial intelligenceElectroencefalografiabusinesslcsh:Engineering (General). Civil engineering (General)030217 neurology & neurosurgerylcsh:Physics
researchProduct

Electroluminescence TPCs at the thermal diffusion limit

2019

Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM

ElectroluminiscènciaNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsDark Matter and Double Beta DecayFOS: Physical scienceschemistry.chemical_elementElectronAtomic01 natural sciences7. Clean energyMathematical SciencesHigh Energy Physics - ExperimentTECNOLOGIA ELECTRONICAHigh Energy Physics - Experiment (hep-ex)Particle and Plasma PhysicsXenonIonization0103 physical sciencesDark Matter and Double Beta Decay (experiments)Nuclearlcsh:Nuclear and particle physics. Atomic energy. RadioactivityDiffusion (business)010306 general physicsMathematical PhysicsPhysicsQuantum Physics010308 nuclear & particles physicsResolution (electron density)MolecularFísicaNuclear energyInstrumentation and Detectors (physics.ins-det)Nuclear & Particles PhysicsParticle correlations and fluctuations85-05ElectroluminescencechemistryRare decayYield (chemistry)Photon productionPhysical SciencesScintillation counterEnergia nuclearlcsh:QC770-798Atomic physicsEnergy (signal processing)
researchProduct

Near-intrinsic energy resolution for 30-662 keV gamma rays in a high pressure xenon electroluminescent TPC

2013

We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 Xe-136 neutrino-less double beta decay (0 nu beta beta) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of similar to 1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and similar to 5% FWHM for 30 keV fluorescence xenon X-…

ElectroluminiscènciaNuclear and High Energy PhysicsXenonHigh-pressureDark matterchemistry.chemical_elementNuclear physicsTECNOLOGIA ELECTRONICAXenonDouble beta decayEnergy resolutionNeutrinoless double beta decayInstrumentationPhysicsTime projection chamberDetectorResolution (electron density)Gamma rayFísicaNuclear energyFull width at half maximumchemistryElectroluminescenceEnergia nuclearTPC
researchProduct

Efficient Low-Frequency Modal Analysis of Anechoic Chamber

2007

An efficient method to analyze the electromagnetic field inside rectangular anechoic and semianechoic chambers from 30 to 100 MHz is shown. A modal expansion is employed to develop the homogeneous and the inhomogeneous field. This is combined with circuital techniques to compute the effect of the layers of ferrite and dielectrics in the walls of the chamber. Several numerical results of the Free Space Transmission Loss (FSTL) of an anechoic chamber and the Normalized Site Attenuation (NSA) of a semianechoic chamber are provided.

Electromagnetic fieldEngineeringAnechoic chamberPhysics::Instrumentation and Detectorsbusiness.industryAttenuationModal analysisAcousticsTransmission lossDielectricLow frequencyPhysics::Classical PhysicsFerrite (magnet)business2007 IEEE International Symposium on Electromagnetic Compatibility
researchProduct

Transcutaneous transfer energy system designing for electronic pills

2015

Abstract This paper proposes a system capable of transcutaneous electric power delivery by means of a non-guided electromagnetic field, suitable for electronic pill technology to be continually powered without the limitations imposed by batteries. This system consists of a Class-E power oscillator, with a crystal-based feedback network to compensate automatically for changes in the operational frequency, multi-turn spiral coupled coils and a power recovery circuit providing a stable output voltage. The synthesis procedure is based on designing equations for optimizing the link efficiency. The proposed transcutaneous transfer energy system aims at transferring 100 mW and providing a stable 3…

Electromagnetic fieldEngineeringbusiness.industryApplied MathematicsElectrical engineeringCondensed Matter PhysicsPower (physics)Transmission (telecommunications)Electronic engineeringWorkbenchElectronicsElectric powerElectrical and Electronic EngineeringSpiral (railway)businessInstrumentationVoltageMeasurement
researchProduct

A Geant4 simulation package for the sage spectrometer

2012

International audience; A comprehensive Geant4 simulation was built for the SAGE spectrometer. The simulation package includes the silicon and germanium detectors, the mechanical structure and the electromagnetic fields present in SAGE. This simulation can be used for making predictions through simulating experiments and for comparing simulated and experimental data to better understand the underlying physics.

Electromagnetic fieldHistorySiliconSpectrometer010308 nuclear & particles physicsComputer sciencePhysics::Instrumentation and DetectorsDetectorchemistry.chemical_elementExperimental dataGermaniumComputerApplications_COMPUTERSINOTHERSYSTEMS[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesComputer Science ApplicationsEducationComputational scienceKokeellinen ydinfysiikkachemistry0103 physical sciencesComputer Science::Mathematical Software29.40.Wk Solid-state detectors 29.30.Kv X- and gamma-ray spectroscopy 07.85.Nc X-ray and gamma-ray spectrometers 29.30.Dn Electron spectroscopyExperimental nuclear physics010306 general physics
researchProduct

A deep study of the high–energy transient sky

2021

This is an open access article. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds t…

Electromagnetic spectrumESA voyage 2050; High-energy transient sky; Multi-messenger astrophysics; Space mission concept; X–/γ–ray polarimetry; X–/γ–ray telescopes01 natural sciences7. Clean energylaw.inventionSettore FIS/05 - Astronomia E AstrofisicalawNuclear astrophysicsoptical010303 astronomy & astrophysicsmedia_commonPhysicsdensityStrong gravityAstrophysics::Instrumentation and Methods for AstrophysicsnucleosynthesisimagingParticle accelerationHigh-energy transient skyNeutrinoburstparticlelensmedia_common.quotation_subjectAstrophysics::High Energy Astrophysical PhenomenainterferometerSpace mission conceptTelescope0103 physical sciencesTeVequation of statepolarization010308 nuclear & particles physicsGravitational wavenucleusgravitational radiationAmbientaleAstronomyAstronomy and AstrophysicsaccelerationsensitivityMulti-messenger astrophysicsUniversemonitoringelectromagneticX–/γ–ray telescopesangular resolution[SDU]Sciences of the Universe [physics]13. Climate actionSpace and Planetary Sciencegamma raygravitationX–/γ–ray polarimetry[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]ESA voyage 2050
researchProduct