Search results for "Ioni"
showing 10 items of 14048 documents
Charge breeding at GANIL: Improvements, results, and comparison with the other facilities
2019
International audience; The 1+/n+ method, based on an ECRIS charge breeder (CB) originally developed at the LPSC laboratory, is now implemented at GANIL for the production of Radioactive Ion Beams (RIBs). Prior to its installation in the middle of the low energy beam line of the SPIRAL1 facility, the 1+/n+ system CB has been modified based on the experiments performed on the CARIBU Facility at Argone National Laboratory. Later, it has been tested at the 1+/n+ LPSC test bench to validate its operation performances. Charge breeding efficiencies as well as charge breeding times have been measured for noble gases and alkali elements. The commissioning phase started at GANIL in the second half-y…
Risk Assessment of Electron Induced SEE during the JUICE Mission
2018
The SEE sensitivity of electronic devices to high energy electrons has been put in evidence experimentally. Several ground experiments have shown that electron induced SEE could occur in recent technologies. In the case of the JUICE mission, the expected electron environment is harsher than for Earth orbits. The impact of such electron fluxes on the embedded electronics was assessed in this work. The study focused on SRAM memories SEU sensitivity. Three different device references were tested under electrons, as well as under protons and heavy ions. The electron and the low energy proton direct ionization contributions to the total SEU rate have been studied in more detail.
Simulations on time-of-flight ERDA spectrometer performance
2016
The performance of a time-of-flight spectrometer consisting of two timing detectors and an ionization chamber energy detector has been studied using Monte Carlo simulations for the recoil creation and ion transport in the sample and detectors. The ionization chamber pulses have been calculated using Shockley-Ramo theorem and the pulse processing of a digitizing data acquisition setup has been modeled. Complete time-of-flight–energy histograms were simulated under realistic experimental conditions. The simulations were used to study instrumentation related effects in coincidence timing and position sensitivity, such as background in time-of-flight–energy histograms. Corresponding measurement…
Lead evaporation instabilities and failure mechanisms of the micro oven at the GTS-LHC ECR ion source at CERN
2020
The GTS-LHC ECR ion source (named after the Grenoble Test Source and the Large Hadron Collider) at CERN provides heavy ion beams for the chain of accelerators from Linac3 up to the LHC for high energy collision experiments and to the Super Proton Synchrotron for fixed target experiments. During the standard operation, the oven technique is used to evaporate lead into the source plasma to produce multiple charged lead ion beams. Intensity and stability are key parameters for the beam, and the operational experience is that some of the source instabilities can be linked to the oven performance. Over long operation periods of several weeks, the evaporation is not stable which makes the tuning …
Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization
2020
A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a Floating Gate (FG) MOS discharge principle. The output current is processed by a current-to-voltage (I/V) interface and then converted by a 5-bit flash ADC. The dosimeter is re-usable (FG can be recharged) and can detect a dose up to 1krad (Si) with a resolution of 30rad (Si) typical over temperature 0 to 85°C range. The ADC allows easy further signal processing for calibration and averaging, etc. The power consumption of C-sensor plus I/V interface is < 2mW from a 5 V power supply. The overall layout area is less than 0.25mm2. The Rad…
pKa at Quartz/Electrolyte Interfaces.
2016
Acidity of silanol sites at the crystalline quartz/aqueous electrolyte (NaCl, NaI, KCl) interfaces are calculated from ab initio molecular dynamics simulations. pKa’s are found to follow a combination of the cationic and anionic Hofmeister series in the order pKa(neat solution) < pKa(NaCl) < pKa(NaI) < pKa(KCl), in agreement with experimental measurements. Rationalization of this ranking is achieved in terms of the microscopic local solvation of the protonated silanols and their conjugated bases, the silanolates SiO–. The change in the pKa is the result of both water destructuring by alkali halides, as well as of the specific cation/SiO– interaction, depending on the electrolyte. M…
Ab initio determination of the ionization potentials of water clusters (H2O)n (n = 2-6).
2012
High-level quantum-chemical ab initio coupled-cluster and multiconfigurational perturbation methods have been used to compute the vertical and adiabatic ionization potentials of several water clusters: dimer, trimer, tetramer, pentamer, hexamer book, hexamer ring, hexamer cage, and hexamer prism. The present results establish reference values at a level not reported before for these systems, calibrating different computational strategies and helping to discard less reliable theoretical and experimental data. The systematic study with the increasing size of the water cluster allows obtaining some clues on the structure and reductive properties of liquid water.
Direct mass measurements and ionization potential measurements of the actinides
2019
Abstract The precise determination of atomic and nuclear properties such as masses, differential charge radii, nuclear spins, electromagnetic moments and the ionization potential of the actinides has been extended to the late actinides in recent years. In particular, laser spectroscopy and mass spectrometry have reached the region of heavy actinides that can only be produced only at accelerator facilities. The new results provide deeper insight into the impact of relativistic effects on the atomic structure and the evolution of nuclear shell effects around the deformed neutron shell closure at N = 152. All these experimental activities have also opened the door to extend such measurements t…
Measurement of the laser resonance ionization efficiency for lutetium
2019
Abstract The development of a highly efficient resonance ionization scheme for lutetium is presented. A laser ion source, based on the all-solid-state Titanium:sapphire laser system, was used at the 30 keV RISIKO off-line mass separator to characterize different possible optical excitation schemes in respect to their ionization efficiency. The developed laser resonance ionization scheme can be directly applied to the use at radioactive ion beam facilities, e. g. at the CERN-MEDICIS facility, for large-scale production of medical radioisotopes.
Photoionization cross sections of the 5S1/2 and 5P3/2 states of Rb in simultaneous magneto-optical trapping of Rb and Hg
2018
We report the measurement of the photoionization cross sections of the $5{S}_{1/2}$ and $5{P}_{3/2}$ states of $^{87}\mathrm{Rb}$ in a two-species Hg and Rb magneto-optical trap (MOT) by the cooling laser for Hg. The photoionization cross sections of Rb in the $5{S}_{1/2}$ and $5{P}_{3/2}$ states at 253.7 nm are determined to be ${1}_{\ensuremath{-}1}^{+4.3}\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}20}\phantom{\rule{0.28em}{0ex}}{\text{cm}}^{2}$ and $4.63(30)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}\phantom{\rule{0.28em}{0ex}}{\text{cm}}^{2}$, respectively. To measure the $5{S}_{1/2}$ and $5{P}_{3/2}$ state fractions in the MOT we detected the photoionization rat…