Search results for "Laser diode"
showing 10 items of 23 documents
Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes
2017
This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3mm wall thickn…
Multi-spectral photoplethysmography biosensor
2011
A photoplethysmography (PPG) signal can provide very useful information about a subject's hemodynamic status in a hospital or home environment. A newly developed portable multi-spectral photoplethysmography device has been used for studies of 11 healthy subjects. The developed optical fiber biosensor comprises one multi-wavelength laser diode (405nm, 660nm and 780nm) and a single photodiode with multi-channel signal output processing and built in Li-ion accumulator; special software was created for visualization and measuring of the MS-PPG signals. ARM7TDMI-S LPC2148, NXP (founded by Philips) 32 bit processor with clock frequency of 60 MHz performs measurement and analysis of the signal.
Hydrogen sensor based on a palladium-coated fibre-taper with improved time-response
2006
Abstract We report an experimental study of the response of a hydrogen sensor, based on a palladium-coated tapered optical fibre, at different temperatures in the range −30 to 80 °C. We have studied the transmission, the time-response and the initial response velocity, being able to correlate these measurements with the pressure–composition isotherms of the Pd–H system and its phase transitions. Heating of the palladium layer optically with an auxiliary laser diode permits to improve the sensor's time-response at low temperatures.
Selective Excitation of Guided Waves into Bone Phantoms by a Time-Delayed Laser Diode Array
2012
We excite selectively the Ao and So plate mode into an acrylic bone phantom using a laser diode array. This is done by controlling the time delay between the signals driving the array elements. Selective mode generation is important because it can potentially increase the sensitivity of in vivo osteoporosis screening.
Intra-center and recombination luminescence of bismuth defects in fused and unfused amorphous silica fabricated by SPCVD
2013
Abstract Photoluminescence (PL) of bismuth doped silicon dioxide excited by UV excimer lasers (ArF — 193 nm, KrF — 248 nm) and a green light laser diode (532 nm) is studied in a wide spectral band at temperatures ranging from 12 to 750 K. Two types of samples are investigated: unfused, 100 μm in thickness amorphous layer immediately deposited on the inner surface of silica substrate tube, and the same material after profusion resulted from tube collapsing to a rod by external heating. PL bands centered at 620–650 nm, 820 nm and 1400 nm wavelengths are observed in both fused and unfused samples. Under excitation by the green laser diode decay time constants for 650 nm (orange) and 1400 nm (N…
Optical characterization of phase transitions in pure polymers and blends
2015
To study the optical properties of polymeric samples, an experimental apparatus was designed on purpose and set up. The sample is a thin film enclosed between two glass slides and a PTFE frame, with a very thin thermocouple placed on sample for direct temperature measurement. This sample holder was placed between two aluminum slabs, equipped with a narrow slit for optical measurements and with electrical resistances for temperature control. Sample was enlightened by a laser diode, whereas transmitted light was detected with a photodiode. Measurements were carried out on polyethylene-terephtalate (PET) and two different polyamides, tested as pure polymers and blends. The thermal history impo…
Analysis of the imaging method for assessment of the smile of laser diode bars.
2009
We study imaging systems designed to assess the smile of laser diode bars (LDBs). The magnification matrix is derived from the required sampling period and the geometries of the LDBs and the charge-coupled device (CCD) array. These image-forming systems present in-plane pure translation invariance, but in the case of anamorphic ones, lack in-plane rotation invariance. It is shown that the smile parameters of the image of the LDB are linked with the smile parameters of the LDB by simple mathematical expressions. The spatial resolution of such optical systems is estimated at approximately 1 microm for a mean wavelength of lambda approximately 800 nm. Our results suggest that, with the current…
Light Scattering Measurements of Hemoglobin Critical Fluctuation and the Energy Landscape For Polymerization
2010
We have developed a novel method for measuring light scattering to observe critical fluctuations in hemoglobin (Hb) solutions. A small rectangular cell (0.2 x 4.0 x 30 mm) is filled with 24 μL of Hb solution. An optical fiber with outer diameter of 125 μm (62.5 μm core) is sealed into the cell in contact with the solution, and light scattering is measured at 90°. The flat faces of the cell permit measuring absorbance spectra to ensure sample integrity. The scattering source is a 785 nm laser diode that delivers 1.5 mW to the sample. Scattered light is detected by a Hamamatsu GaAs(Cs) PMT via a LWD microscope objective. Measured scattered light intensity agrees (±10%) with scattered intensit…
Highly Efficient Holmium-Doped All-Fiber ∼2.07-μm Laser Pumped by Ytterbium-Doped Fiber Laser at ∼1.13 μm
2018
We report a 2.07-μm Holmium-doped all-fiber laser (HDFL) pumped by a 1.13-μm Ytterbium-doped fiber laser (YDFL). Home-made alumino–germano–silicate holmium-doped fiber (HDF) served here as an active medium, optimized in terms of chemical composition and co-dopants’ concentrations. Laser action at 2.07 μm was assessed in simple Fabry–Perot cavity, formed by a couple of home-made fiber Bragg gratings (FBGs), inscribed directly in the HDF; this allowed notable diminishing of intracavity loss of the 2.07-μm laser. HDF was in-core pumped by the 1.13-μm double-clad YDFL with a power of ∼12.5 W, in turn pumped in-clad by a laser diode (LD) operated at 0.97 μm with ∼24.5-W output. Using optimal len…
Application of WGM Resonances to the Measurement of the Temperature Increment of Ho and Ho-Yb Doped Optical Fibers Pumped at 1125 and 975 nm
2021
Optical fiber characterization using whispering gallery mode resonances of the fiber itself has been demonstrated to be a powerful technique. In this work, we exploit the thermal sensitivity of whispering gallery mode resonances to characterize the pump-induced temperature increment in holmium doped and holmium-ytterbium codoped optical fibers. The technique relies on the measurement of the resonances’ wavelength shift due to temperature variation as a function of the pump power. Holmium doped fibers were pumped to the second excited level 5I6 of the Ho3+ ion using a laser diode at 1125 nm and ytterbium-holmium codoped fibers to the 2F5/2 level of the Yb3+ ion by a laser diode at 975 nm. Ou…