Search results for "Lasers"
showing 10 items of 316 documents
Comparison between 2 Different Composite Nd3+:YVO4 Crystals in a Fibre Coupled Diode Pumped Laser
2008
International audience; We detail the performances of two composite Nd3+YVO4crystals, realised with two different sticking techniques. We tested them inside a fibre coupled diode end pumped laser.
Multidimensional shaping of spatiotemporal waves in multimode nonlinear fibers
2019
Recent experiments have shown that nonlinear wave propagation in multimode optical fibers leads to complex spatio-temporal phenomena. In this talk, we introduce new approaches for the control and optimization of nonlinear beam reshaping in the spatial, temporal and spectral dimensions. The first approach applies to spatial beam self-cleaning the technique of transverse wavefront shaping, which permits to launch an optimized input mode combination, that results in the stable generation of a whole nonlinear mode alphabet at the fiber output. The second approach introduces a longitudinal tapering of the core diameter of multimode active and passive fibers, which permits to generate ultra-wideb…
Universal soliton pattern formations in passively mode-locked fiber lasers
2011
International audience; We investigate multiple-soliton pattern formations in a figure-of-eight passively mode-locked fiber laser. Operation in the anomalous dispersion regime with a double-clad fiber amplifier allows generation of up to several hundreds of solitons per round trip. We report the observation of remarkable soliton distributions: soliton gas, soliton liquid, soliton polycrystal, and soliton crystal, thus indicating the universality of such complexes.
Piranilidena atvasinājumu optiskās un pastiprinātas spontānās emisijas īpašības PVK matricā
2015
Organiskie materiāli ir daudzsološi dažādiem moderniem pielietojumiem, tai skaitā optiski ierosinātiem organiskajiem cietvielu lāzeriem, kuriem vajadzīgi materiāli ar augstu pastiprināšanās koeficientu un zemām ierosmes enerģijām. Vairumā organisko sistēmu šie parametri ir limitēti krāsvielu molekulu kristalizācijas dēļ. Tādēļ savienojumi ar samazinātu kristalizēšanos būtu ļoti noderīgi. Šajā darbā tika pētītas plānās kārtiņas ar jauniem plaši zināmās krāsvielas DCM atvasinājumiem PVK polimēra matricā dažādās koncentrācijās. Kārtiņām tika uzņemti fotoluminiscences spektri un veikti pastiprinātas spontānās emisijas (PSE) mērījumi. Tika novērota spēcīga koncentrācijas ietekme uz emisijas spek…
Molecular structures and vibrations of m-methylaniline in the S0 and S1 states studied by laser induced fluorescence spectroscopy and ab initio calcu…
2000
Abstract The UV fluorescence excitation and dispersed fluorescence spectra of a jet-cooled m-methylaniline have been obtained for the S1←S0 transition, in which some of the bands have been observed for the first time. The main spectral bands have been assigned by comparison with those of other relevant substituted benzenes. It was found that the spectra exhibit an important feature which is the internal rotation of the methyl group in the electronic ground and excited states. Ab initio calculations at MP2/6-31G* and CIS/6-31G* show that the optimized structure of m-methylaniline in the ground state is not planar with the amino group having sp3 hybridation-like character due to the existence…
In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis…
2009
Abstract A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatog…
The primary structural photoresponse of phytochrome proteins captured by a femtosecond X-ray laser
2020
Please check the README file for more information about the dataset.
Non-linear interactions of femtosecond laser pulses with graphene : photo-oxidation, imaging and photodynamics
2017
This thesis presents a study focused on interactions of femtosecond laser pulses with graphene, a one atom thick carbon membrane. Graphene, which exhibits exceptional electronic and optoelectronic properties, could provide considerable advantage over current silicon-based electronics. Graphene alone, being semi-metal, is not sufficient for electronic applications, but requires modification. For this, a set of methods for modifying and measuring the properties of graphene was developed. With the perspective of making graphene a suitable component for electronics, optoelectronics or photonics, ultrashort laser pulses were used for drawing patterns on graphene. The procedure modifies graphene …
Performance analysis of dual-pump nonlinear amplifying loop mirror mode-locked all-fibre laser
2019
We numerically characterise, in the three-dimensional space of adjustable cavity parameters, the performance of a recently reported layout of a flexible figure-8 laser having two independently pumped segments of active fibre in its bidirectional ring (Smirnov et al 2017 Opt. Lett. 42 1732–5). We show that this optimisation problem can be efficiently addressed by applying a regression model based on a neural-network algorithm.
Volcanic CO2 flux measurement at Campi Flegrei by tunable diode laser absorption spectroscopy
2014
Near-infrared room-temperature Tunable Diode Lasers (TDL) have recently found increased usage in atmospheric chemistry and air monitoring research, but applications in volcanology are still limited to a few examples. Here, we explored the potential of a commercial infrared laser unit (GasFinder 2.0 from Boreal Laser Ltd) for measurement of volcanic CO2 mixing ratios, and ultimately for estimating the volcanic CO2 flux. Our field tests were conducted at Campi Flegrei near Pozzuoli, Southern Italy, where the GasFinder was used during three campaigns in October 2012, January 2013 and May 2013 to repeatedly measure the path-integrated mixing ratios of CO2 along cross-sections of the atmospheric…