Search results for "Lens Implantation"

showing 10 items of 140 documents

Contrast sensitivity and color perception with orange and yellow intraocular lenses

2012

To evaluate contrast sensitivity function (CSF) and color vision after implantation of either orange or yellow-tinted intraocular lenses (IOLs).Fifty-six eyes of 28 cataract patients who had bilateral implantation of orange-tinted (PC440Y Orange, Ophtec), yellow-tinted (AcrySof Natural SN60AT, Alcon), or clear (AcrySof SA60AT, Alcon) IOLs were examined. Six months postoperatively, monocular CSF under photopic and mesopic (with and without glare) conditions were measured using the Functional Visual Analyzer. Color discrimination was determined with the Farnsworth-Munsell 100-Hue test.Patients implanted with orange-tinted, yellow-tinted, or clear IOLs displayed similar CSF values, with no sta…

Male0301 basic medicinemedicine.medical_specialtygenetic structuresColor visionmedicine.medical_treatmentMesopic VisionVisual AcuityOrange (colour)Prosthesis DesignColor discriminationContrast Sensitivity03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOphthalmologyHumansMedicineProsthesis designProspective StudiesAgedLenses IntraocularPhacoemulsificationColor Visionbusiness.industryGeneral MedicinePhacoemulsificationeye diseasesOphthalmology030104 developmental biologyIntraocular lenses030221 ophthalmology & optometryFemalesense organsbusinessColor PerceptionEuropean Journal of Ophthalmology
researchProduct

Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction.

2019

To study the agreement between manifest refraction and objective refraction measured with two autorefractor models and an aberrometer in eyes implanted with a trifocal diffractive intraocular lens (IOL).IOA Madrid Innova Ocular, Madrid, Spain.Prospective comparative cohort study.An autorefractor keratometer (KR-8800), based on a Scheiner double pinhole, and a 3-dimension wavefront topography aberrometer system (OPD-Scan III), based on the scanning-slit retinoscopy principle, were used to obtain objective refraction readings. In addition, lower-order Zernike coefficients (Z) were used to calculate objective refraction. A set of 7 different results was obtained in power vector notation (spher…

MaleCorneal Wavefront AberrationPseudophakiaMesopic visionZernike polynomialsmedicine.medical_treatmentVisual AcuityIntraocular lensRefraction OcularPupillaw.inventionsymbols.namesakeLens Implantation IntraocularlawmedicineHumansProspective StudiesRetinoscopyMathematicsAgedPhacoemulsificationmedicine.diagnostic_testKeratometerAberrometryMiddle AgedMultifocal Intraocular LensesSensory SystemsOphthalmologyAutorefractorsymbolsOptometrySurgeryFemalePhotopic visionJournal of cataract and refractive surgery
researchProduct

A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma

2014

Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…

MaleIntraocular pressureVisual acuityMinimally invasive glaucoma surgerymedicine.medical_treatmentVisual AcuityGlaucomalaw.inventionRandomized controlled trialLens Implantation Intraocularlaw80 and overMedicineSingle-Blind MethodProspective StudiesProspective cohort studyGlaucoma Drainage ImplantsAged 80 and overIntraocularMedicine (all)Adult; Aged; Aged 80 and over; Antihypertensive Agents; Female; Follow-Up Studies; Glaucoma Open-Angle; Humans; Intraocular Pressure; Lens Implantation Intraocular; Limbus Corneae; Male; Middle Aged; Prospective Studies; Prosthesis Implantation; Single-Blind Method; Tonometry Ocular; Visual Acuity; Visual Fields; Young Adult; Glaucoma Drainage Implants; Phacoemulsification; Stents; Ophthalmology; Medicine (all)Middle AgedOpen-AngleFemaleStentsmedicine.symptomLens ImplantationGlaucoma Open-AngleAdultmedicine.medical_specialtyLimbus CorneaeTonometryProsthesis ImplantationTonometry OcularYoung AdultOphthalmologyOcularHumansAntihypertensive AgentsIntraocular PressureAgedPhacoemulsificationbusiness.industryGlaucomaPhacoemulsificationCataract surgerymedicine.diseaseOphthalmologyVisual FieldsbusinessFollow-Up Studies
researchProduct

European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma

2020

indexation en cours.; PURPOSE: This study investigated the efficacy and safety of a cross-linked collagen stent (XEN 45) with or without cataract surgery in the treatment of glaucoma. SETTING: Real-life setting. DESIGN: Prospective, open-label, multicenter clinical trial. METHODS: Eligible patients with glaucoma inadequately controlled by treatment, or poor compliance or intolerance to topical therapy were included. Patients were divided into those with implant only (solo group; phakic and pseudophakic patients) and implant combined with cataract surgery (combo group). Differences in average intraocular pressure (IOP) and number of medications between baseline and study end (12 months), and…

MaleIntraocular pressuregenetic structuresmedicine.medical_treatmentVisual AcuityGlaucomasurgery0302 clinical medicineLens Implantation IntraocularimplantationProspective StudiesGlaucoma Drainage ImplantsAged 80 and overDry needlingMiddle AgedSensory Systems3. Good healthEuropeTreatment OutcomeFemaleStentsGlaucoma Open-Anglesafetymedicine.medical_specialtyintraocular-pressurepredictive-value03 medical and health sciencesTonometry OcularmedicineHumans[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrganssuccessIntraocular PressureAgedbusiness.industryStentPhacoemulsificationCataract surgerymedicine.diseaseeye diseasesSurgeryClinical trialOphthalmologyphacoemulsification030221 ophthalmology & optometryImplantsense organsbusiness030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyFollow-Up Studies
researchProduct

Posterior‐chamber phakic implantable collamer lenses with a central port: a review

2020

Abstract We aimed to summarize the outcomes reported following the implantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc) for myopia correction. A literature search in PubMed, Web of Science and Scopus was carried out to identify publications reporting clinical outcomes of patients who were implanted with the V4c ICL model and had a follow‐up period of at least 6 months. A total of 35 clinical studies published between 2012 and 2020 were included in the present review. A comprehensive analysis of the available data was performed, focusing on visual and refractive outcomes at different time‐points post‐surgery. In addition, adverse events and other pa…

MaleIntraocular pressuremedicine.medical_specialtyPhakic Intraocular LensesVisual acuityWeb of sciencevisual acuityReview ArticleRefraction Ocular03 medical and health sciences0302 clinical medicinePort (medical)vaultLens Implantation IntraocularOphthalmologymedicineMyopiaphakicHumansReview ArticlesIntraocular PressureImplantable collamer lensrefractionbusiness.industryimplantable collamer lensGeneral Medicineadverse eventsEndothelial cell densityOphthalmology030221 ophthalmology & optometryFemalemedicine.symptombusiness030217 neurology & neurosurgeryActa Ophthalmologica
researchProduct

Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses

2013

Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…

MaleRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentMesopic VisionVisual AcuitySettore MED/42 - Igiene Generale E ApplicataLens Implantation IntraocularSickness Impact ProfileSurveys and QuestionnairesMedicineContrast (vision)Prospective StudiesProspective cohort studyOPTICAL-QUALITYmedia_commonLenses IntraocularVision BinocularOUTCOMESMiddle AgedRESTORFemalemedicine.symptomA+3.00 DPhotopic visionDIOPTER ADDITIONmedicine.medical_specialtyINSTITUTE-REFRACTIVE ERRORmedia_common.quotation_subjectMODELSProsthesis DesignCataractDouble-Blind MethodOphthalmologyCONTRAST SENSITIVITYHumansBILATERAL IMPLANTATIONPhacoemulsificationColor Visionbusiness.industrySettore MED/30 - Malattie Apparato VisivoPhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyVISIONINSTITUTE-REFRACTIVE ERROR; CONTRAST SENSITIVITY; BILATERAL IMPLANTATION; DIOPTER ADDITION; OPTICAL-QUALITY; A+3.00 D; VISION; RESTOR; OUTCOMES; MODELSReadingQuality of LifeOptometryMultifocal IOL diffractive Quality of lifebusinessFollow-Up Studies
researchProduct

Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens

2009

Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …

MaleRefractive errormedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensContrast SensitivityVision disorderTonometry OcularLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraocular PressureDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryHipermetropíaPresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOftalmologíaOptometryFemalesense organsmedicine.symptombusinessPhotopic visionAmerican Journal of Ophthalmology
researchProduct

Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

2007

To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…

MaleRefractive errormedicine.medical_specialtyVisual acuitygenetic structuresPseudophakiaEye diseasemedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensResidualVision disorderPostoperative ComplicationsApodizationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansProspective StudiesAgedLenses IntraocularMonocularbusiness.industryMiddle Agedmedicine.diseaseRefractive Errorseye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Foldable toric intraocular lens for astigmatism correction in cataract patients.

2007

PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…

MaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensAstigmatismRefraction OcularVision disorderLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Outcomes of cataract surgery in diabetic patients: results of the Pan American Collaborative Retina Study Group.

2014

Purpose: This study was designed to evaluate the visual and anatomical outcomes after cataract surgery in diabetic patients with different intraoperative therapeutic strategies. Methods: The research design comprised of a multicentric, retrospective, interventional study conducted at 6 centers in Argentina, Brazil, Costa Rica, Puerto Rico, Spain, and Venezuela. We included 138 diabetic patients with at least 6-month follow-up following phacoemulsification and intraocular lens implantation. Best-corrected visual acuity (BCVA) and central subfield thickness were collected at baseline and at 1-, 2-, 3-, and 6-month follow-up. Of these, 42 cases were not treated with any intraoperative coadjuva…

MaleVascular Endothelial Growth Factor ATriamcinolone acetonideVisual acuitygenetic structuresmedicine.medical_treatmentExtração de catarataVisual AcuityIntraocular lensCuidados intraoperatóriosAngiogenesis InhibitorsTriamcinolonelcsh:OphthalmologyLens Implantation IntraocularDiabetic retinopathyAntibodies monoclonalAged 80 and overGeneral MedicineDiabetic retinopathyMiddle AgedMulticenter studyBevacizumabTreatment OutcomeCataract extractionChemotherapy AdjuvantEstudo multicêntricoIntravitreal InjectionsFemalemedicine.symptommedicine.drugAdultmedicine.medical_specialtyBevacizumabAntibodies Monoclonal HumanizedCataractMacular EdemaIntraoperative careOphthalmologyEdema macularmedicineAnticorpos monoclonaisHumansMacular edemaGlucocorticoidsAgedRetrospective StudiesMacular edemaDiabetic RetinopathyIntraoperative CarePhacoemulsificationbusiness.industryRetinopatia diabéticaPhacoemulsificationCataract surgeryFacoemulsificaçãomedicine.diseaseSurgeryImplante de lente intraocularOphthalmologyLens implantation intraocularlcsh:RE1-994businessFollow-Up StudiesArquivos brasileiros de oftalmologia
researchProduct