Search results for "Magnetometer"

showing 10 items of 102 documents

Spherical fused silica cells filled with pure helium for nuclear magnetic resonance-magnetometry.

2016

High magnetic fields (> 1 T) are measured by NMR magnetometers with un-rivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted ${}^{3}$He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field the optimal container for the ${}^{3}$He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO${}_{2}$ laser and the inner…

Materials scienceMagnetometerchemistry.chemical_elementLaser01 natural sciences010305 fluids & plasmasMagnetic fieldlaw.inventionSphericitychemistrylaw0103 physical sciencesHomogeneity (physics)Atomic physics010306 general physicsInstrumentationDiffusion bondingHeliumCoherence (physics)The Review of scientific instruments
researchProduct

The Shielding Effect of Drilling Fluids on MWD Downhole Compasses: The Effect of Drilling Fluid Composition, Contaminants and Rheology

2014

Materials such as added clays, weight materials, drill solids and metalic wear products in the drilling fluid are known to distort the geomagnetic field at the location of the Measurement While Drilling (MWD) tool magnetometers that are used to measure the direction of well path. This distortion contributes to substantial errors in determination of azimuth while drilling deviated wells. These errors may result in missing the target of a long deviated 12 ¼″ section in the range of 1–200m; representing a significant cost to be mitigated. The error becomes even more pronounced if drilling occurs in arctic regions close to the magnetic North Pole (or South Pole). The effect on the magnetometer …

Materials sciencePetroleum engineeringMagnetometerlawDrilling fluidBentoniteElectromagnetic shieldingMineralogyDrillingMeasurement while drillingOffshore drillingSwarflaw.inventionVolume 5: Materials Technology; Petroleum Technology
researchProduct

The Shielding Effect of Drilling Fluids on Measurement While Drilling Tool Downhole Compasses—The Effect of Drilling Fluid Composition, Contaminants,…

2016

Materials such as added clays, weight materials, drill solids, and metallic wear products in the drilling fluid are known to distort the geomagnetic field at the location of the measurement while drilling (MWD) tool magnetometers that are used to measure the direction of well path. This distortion contributes to substantial errors in determination of azimuth while drilling deviated wells. These errors may result in missing the target of a long deviated 12 ¼ in. section in the range of 1–200 m, representing a significant cost to be mitigated. The error becomes even more pronounced if drilling occurs in arctic regions close to the magnetic north pole (or south pole). The effect on the magneto…

Materials sciencePetroleum engineeringRenewable Energy Sustainability and the EnvironmentMagnetometerMechanical EngineeringEnergy Engineering and Power TechnologyDrilling02 engineering and technology010502 geochemistry & geophysics01 natural scienceslaw.inventionFuel Technology020401 chemical engineeringRheologyGeochemistry and PetrologylawDrilling fluidElectromagnetic shieldingShielding effectMeasurement while drillingGeotechnical engineering0204 chemical engineering0105 earth and related environmental sciencesJournal of Energy Resources Technology
researchProduct

Diamond magnetometer enhanced by ferrite flux concentrators

2020

Magnetometers based on nitrogen-vacancy (NV) centers in diamond are promising room-temperature, solid-state sensors. However, their reported sensitivity to magnetic fields at low frequencies (<1 kHz) is presently >10 pT s^{1/2}, precluding potential applications in medical imaging, geoscience, and navigation. Here we show that high-permeability magnetic flux concentrators, which collect magnetic flux from a larger area and concentrate it into the diamond sensor, can be used to improve the sensitivity of diamond magnetometers. By inserting an NV-doped diamond membrane between two ferrite cones in a bowtie configuration, we realize a ~250-fold increase of the magnetic field amplitude wi…

Materials sciencePhysics - Instrumentation and DetectorsMagnetometerFOS: Physical sciences02 engineering and technologyApplied Physics (physics.app-ph)engineering.material01 natural sciencesArticlelaw.inventionlaw0103 physical sciencesThermalMesoscale and Nanoscale Physics (cond-mat.mes-hall)Laser power scaling010306 general physicsCondensed Matter - Mesoscale and Nanoscale Physicsbusiness.industryMicrowave powerDiamondInstrumentation and Detectors (physics.ins-det)Physics - Applied Physics021001 nanoscience & nanotechnologyMagnetic fluxMagnetic fieldengineeringFerrite (magnet)Optoelectronics0210 nano-technologybusinessOptics (physics.optics)Physics - Optics
researchProduct

Noncovalent force spectroscopy using wide-field optical and diamond-based magnetic imaging

2019

A realization of the force-induced remnant magnetization spectroscopy (FIRMS) technique of specific biomolecular binding is presented where detection is accomplished with wide-field optical and diamond-based magnetometry using an ensemble of nitrogen-vacancy (NV) color centers. The technique may be adapted for massively parallel screening of arrays of nanoscale samples.

Materials sciencePhysics - Instrumentation and DetectorsMagnetometerFOS: Physical sciencesGeneral Physics and AstronomyApplied Physics (physics.app-ph)02 engineering and technologyengineering.material01 natural scienceslaw.inventionMagnetizationlaw0103 physical sciencesPhysics - Biological PhysicsSpectroscopyMassively parallelNanoscopic scale010302 applied physicsQuantum Physicsbusiness.industryForce spectroscopyDiamondInstrumentation and Detectors (physics.ins-det)Physics - Applied Physics021001 nanoscience & nanotechnology3. Good healthBiological Physics (physics.bio-ph)engineeringOptoelectronicsQuantum Physics (quant-ph)0210 nano-technologybusinessRealization (systems)
researchProduct

High-Spatial-Resolution Monitoring of Strong Magnetic Field using Rb vapor Nanometric-Thin Cell

2011

We have implemented the so-called $\lambda$-Zeeman technique (LZT) to investigate individual hyperfine transitions between Zeeman sublevels of the Rb atoms in a strong external magnetic field $B$ in the range of $2500 - 5000$ G (recently it was established that LZT is very convenient for the range of $10 - 2500$ G). Atoms are confined in a nanometric thin cell (NTC) with the thickness $L = \lambda$, where $\lambda$ is the resonant wavelength 794 nm for Rb $D_1$ line. Narrow velocity selective optical pumping (VSOP) resonances in the transmission spectrum of the NTC are split into several components in a magnetic field with the frequency positions and transition probabilities depending on th…

Materials science[ PHYS.QPHY ] Physics [physics]/Quantum Physics [quant-ph]Atomic Physics (physics.atom-ph)MagnetometerAtomic transition intensityFOS: Physical sciencesFrequency shift01 natural scienceslaw.inventionPhysics - Atomic Physics010309 opticsOptical pumpingsymbols.namesakeSubmicron thin vaporOptics[PHYS.QPHY]Physics [physics]/Quantum Physics [quant-ph]law0103 physical sciencesZeeman HamiltonianPhysics::Atomic PhysicsElectrical and Electronic EngineeringPhysical and Theoretical Chemistry010306 general physicsImage resolutionHyperfine structureLine (formation)Condensed Matter::Quantum GasesZeeman effectCondensed matter physicsbusiness.industryAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsMagnetic fieldWavelengthsymbolsAtomic physicsbusiness
researchProduct

Magnetic Field Gradiometer with Sub-Micron Spatial Resolution Based on Caesium Vapour in an Extremely Thin Cell

2015

Abstract In this paper we present a device for measuring the magnetic field and its gradient with a spatial resolution of several hundred nanometres. This device is based on caesium metal vapour confined to an extremely thin cell (ETC). To measure magnetic signals, we use absorption and very low laser powers, which might be appealing for modern fabrication techniques. A portable, fully automated device was constructed.

Materials sciencebusiness.industryMagnetometerGeneral EngineeringGeneral Physics and Astronomychemistry.chemical_elementGradiometerlcsh:QC1-999Magnetic fieldlaw.inventionmeasurements of magnetic field gradientOpticschemistrylawCaesiummagnetometermagneto-optical resonancesextremely thin cellbusinessImage resolutionlcsh:PhysicsLatvian Journal of Physics and Technical Sciences
researchProduct

High homogeneity permanent magnet for diamond magnetometry

2020

Abstract Halbach magnets are a source of homogeneous magnetic field in an enclosed volume while keeping stray fields at a minimum. Here, we present the design, construction, and characterization for a stack of two Halbach rings with 10 cm inner diameter providing a homogeneous ( 100 ppm over 1.0 × 1.0 × 0.5 cm 3 ) magnetic field of around 105 mT, which will be used for a diamond based microwave-free widefield imaging setup. The final characterization is performed with a novel fiberized diamond-based sensor on a 3D translation stage documenting the high homogeneity of the constructed Halbach array and its suitability for the proposed use.

Nuclear and High Energy PhysicsMaterials sciencePhysics - Instrumentation and DetectorsMagnetometerBiophysicsFOS: Physical sciencesApplied Physics (physics.app-ph)engineering.material010402 general chemistry01 natural sciencesBiochemistryHomogeneous magnetic field030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslawHomogeneity (physics)Quantum Physicsbusiness.industryDiamondPhysics - Applied PhysicsInstrumentation and Detectors (physics.ins-det)Condensed Matter Physics0104 chemical sciencesMagnetic fieldDipoleHalbach arrayMagnetengineeringbusinessQuantum Physics (quant-ph)
researchProduct

Zero- to Ultralow-Field Nuclear Magnetic Resonance $J$-Spectroscopy with Commercial Atomic Magnetometers

2019

Zero- to ultralow-field nuclear magnetic resonance (ZULF NMR) is an alternative spectroscopic method to high-field NMR, in which samples are studied in the absence of a large magnetic field. Unfortunately, there is a large barrier to entry for many groups, because operating the optical magnetometers needed for signal detection requires some expertise in atomic physics and optics. Commercially available magnetometers offer a solution to this problem. Here we describe a simple ZULF NMR configuration employing commercial magnetometers, and demonstrate sufficient functionality to measure samples with nuclear spins prepolarized in a permanent magnet or initialized using parahydrogen. This opens …

Nuclear and High Energy PhysicsMaterials scienceZero field NMRPhysics - Instrumentation and DetectorsMagnetometerBiophysicsFOS: Physical sciences010402 general chemistrySpin isomers of hydrogen01 natural sciencesBiochemistry030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineNuclear magnetic resonancelawPhysics - Chemical PhysicsHyperpolarization (physics)SpectroscopyChemical Physics (physics.chem-ph)SpinsInstrumentation and Detectors (physics.ins-det)Condensed Matter Physics0104 chemical sciencesMagnetic fieldMagnet
researchProduct

A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

2015

We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be inter…

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsFOS: Physical sciencesMagnitude (mathematics)01 natural sciencesResonance (particle physics)High Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)Quantum mechanicsPaul-Scherrer InstituteCesium atom0103 physical sciences[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]NeutronLimit (mathematics)010306 general physicsPhysicsConservation lawmagnetic-momentMagnetic moment010308 nuclear & particles physicsInstrumentation and Detectors (physics.ins-det)QC0793Atomic-Mercury magnetometerElectric dipole momentresonanceQuantum electrodynamicsUltracold neutronsParticle Physics - Experiment
researchProduct