Search results for "Microelectronics"
showing 10 items of 234 documents
High quality nano-patterned thin films of the coordination compound {Fe(pyrazine)[Pt(CN)4]} deposited layer-by-layer
2011
International audience; An optimised procedure was developed for the layer-by-layer deposition of the Hofmann clathrate-like coordination compound {Fe(pyrazine)[Pt(CN)4]} either as continuous or as nano-patterned thin films. Characterization of the thickness and topography of the thin films by atomic force microscopy (AFM) and by surface plasmon resonance (SPR) spectroscopy, which also yields the layer's refractive index and losses, are reported. We found that the films are of good optical quality and the results of both AFM and SPR experiments are in good agreement with the theoretical predictions of the films thicknesses.
Optical absorption of torus-shaped metal nanoparticles in the visible range
2007
Received 22 November 2007; published 19 December 2007We theoretically and experimentally investigated the optical response of a thin metal nanotorus in the visiblerange. The close formulas describing the extinction cross sections of a torus are obtained in the nonretardedapproximation. We demonstrate a good agreement between numerical simulations and experimental data. Ourfindings show that the main resonance is highly sensitive to the external medium and the geometrical param-eters of the particle.DOI: 10.1103/PhysRevB.76.245422 PACS number s : 78.67.Bf, 73.20.Mf, 78.20.Ci
Optimization of surface plasmons launching from subwavelength hole arrays: modelling and experiments
2009
International audience; The launching of surface plasmons by micro-gratings of subwavelength apertures milled in a thick metal film is important for the development of surface plasmon based circuits. By comparing the near-field optical images of such surface plasmon sources with the results of a Huygens-Fresnel principle based scattering model, we show that the properties of the locally launched SP beams such as divergence or uniformity can be tuned by adjusting the shape of the micro-gratings. This allows us to propose an optimized source array well adapted for providing a narrow, collimated and uniform beam. (c) 2007 Optical Society of America.
Differential method for modelling dielectric-loaded surface plasmon polariton waveguides
2008
International audience; This paper demonstrates the efficiency of the differential method, a conventional grating theory, to investigate dielectric loaded surface plasmon polariton waveguides (DLSPPWs), known to be a potential solution for optical interconnects. The method is used to obtain the mode effective indices (both real and imaginary parts) and the mode profiles. The results obtained with the differential method are found to be in good agreement with those provided by the effective index method or finite elements. The versatility of the differential method is demonstrated by considering complex configurations such as trapezoidal waveguides or DLSPPWs lying on a finite width metal st…
Direct interpretation of near-field optical images
2001
International audience; The interpretation of the detection process in near-field optical microscopy is reviewed on the basis of a discussion about the possibility of establishing direct comparisons between experimental images and the solutions of Maxwell equations or the electromagnetic local density of states. On the basis of simple physical arguments, it is expected that the solutions of Maxwell equations should agree with images obtained by collecting mode near-field microscopes, while the electromagnetic local density of states should be considered to provide a practical interpretation of illumination mode near-field microscopes. We review collecting mode near-field microscope images w…
Spectral and temporal distribution of biomolecules by Dynamic SERS
2014
In this thesis, the definition of SERS as a biosensor has been tested and a new approach developed for. Also, in terms of quantification, it has been shown that SERS can be an efficient tool. Concerning the selectivity, the spectral quality was improved. A low limit of detection associated to the statistical and dynamic approach allows a very good sensitivity (under the nanomolar). This approach also enables a high reproducibility in time of the sensor. Thus, as low as SERS does not well answer to the sensor capabilities in a classical approach, in our case the coupling between a non-functionalized GNPs substrate coupled with a microfluidic chip, all mounted on a confocal microscope for tem…
Cloaking In-Plane Elastic Waves with Swiss Rolls
2020
We propose a design of cylindrical cloak for coupled in-plane shear waves consisting of concentric layers of sub-wavelength resonant stress-free inclusions shaped as Swiss rolls. The scaling factor between inclusions&rsquo
Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review
2014
Abstract Inductively coupled plasma optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS) can be considered as the most important tools in inorganic analytical chemistry. Huge progress has been made since the first analytical applications of the ICP. More stable RF generators, improved spectrometers and detection systems were designed along with the achievements gained from advanced microelectronics, leading to overall greatly improved analytical performance of such instruments. In contrast, for the vast majority of cases liquid sample introduction is still based on the pneumatic principle as described in the late 19th century. High flow pneumatic nebulizers typically deman…
Integration of GMR sensors with different technologies
2016
Less than thirty years after the giant magnetoresistance (GMR) effect was described, GMR sensors are the preferred choice in many applications demanding the measurement of low magnetic fields in small volumes. This rapid deployment from theoretical basis to market and state-of-the-art applications can be explained by the combination of excellent inherent properties with the feasibility of fabrication, allowing the real integration with many other standard technologies. In this paper, we present a review focusing on how this capability of integration has allowed the improvement of the inherent capabilities and, therefore, the range of application of GMR sensors. After briefly describing the …
Multifunctional platforms for cancer theranosis
2018
The objective of this thesis was to develop multifunctional tools for cancer theranosis, particularly based on nanotechnology. The work is based on the premise of monomolecular multimodal platform that aims to create the building blocks that can be used for the synthesis of functionalized nanoparticles, bioconjugates or targeted small molecular imaging probes.The initial work focused on the synthesis of the chelator based silane precursors. These novel precursors were employed for the functionalization of AGuIX nanoparticles and have also been implicated in a one pot AGuIX synthesis. Radiolabelling of these nanoparticles was performed with the aim to evaluate the stability of these nanopart…