Search results for "Microscope"
showing 10 items of 1412 documents
Collagen-inducing biologization of prosthetic material for hernia repair: Polypropylene meshes coated with polyP/collagen
2017
Prostethic mesh material such as nonabsorbable polypropylene used in open and laparoscopic hernia repair are characterized by controllable mechanical properties but may elicit undesirable physiological reactions due to the nonphysiological inert polymer material. We succeeded in developing a biocompatible coating for these meshes, based on a physiological inorganic polymer, polyphosphate (polyP) that is morphogenetically active and used as a metabolic energy source, and a collagen matrix. The polyP/collagen hydrogel material was prepared by a freeze-extraction method, with amorphous Ca-polyP microparticles. Electron microscopy (SEM and REM) studies revealed that the polyP/collagen coats are…
Flexible multi-beam light-sheet fluorescence microscope for live imaging without striping artifacts
2018
The development of light-sheet fluorescence microscopy (LSFM) has greatly expanded the experimental capabilities in many biological and biomedical research fields, enabling for example live studies of murine and zebrafish neural activity or of cell growth and division. The key feature of the method is the selective illumination of a sample single plane, providing an intrinsic optical sectioning and allowing direct 2D image recording. On the other hand, this excitation scheme is more affected by absorption or scattering artifacts in comparison to point scanning methods, leading to un-even illumination. We present here an easily implementable method, based on acousto-optical deflectors (AOD),…
Tunable-frequency three-dimensional structured illumination microscopy with reduced data-acquisition
2018
The performance of a tunable three-dimensional (3D) structured illumination microscope (SIM) system and its ability to provide simultaneously super-resolution (SR) and optical-sectioning (OS) capabilities are investigated. Numerical results show that the performance of our 3D-SIM system is comparable with the one provided by a three-wave interference SIM, while requiring 40% fewer images for the reconstruction and providing frequency tunability in a cost-effective implementation. The performance of the system has been validated experimentally with images from test samples, which were also imaged with a commercial SIM based on incoherent-grid projection for comparison. Restored images from d…
Transformation of Amorphous Polyphosphate Nanoparticles into Coacervate Complexes: An Approach for the Encapsulation of Mesenchymal Stem Cells.
2018
Inorganic polyphosphate [polyP] has proven to be a promising physiological biopolymer for potential use in regenerative medicine because of its morphogenetic activity and function as an extracellular energy-donating system. Amorphous Ca2+ -polyP nanoparticles [Ca-polyP-NPs] are characterized by a high zeta potential with -34 mV (at pH 7.4). This should contribute to the stability of suspensions of the spherical nanoparticles (radius 94 nm), but make them less biocompatible. The zeta potential decreases to near zero after exposure of the Ca-polyP-NPs to protein/peptide-containing serum or medium plus serum. Electron microscopy analysis reveals that the particles rapidly change into a coacerv…
2019
During lytic herpes simplex virus 1 (HSV-1) infection, the expansion of the viral replication compartments leads to an enrichment of the host chromatin in the peripheral nucleoplasm. We have shown previously that HSV-1 infection induces the formation of channels through the compacted peripheral chromatin. Here, we used three-dimensional confocal and expansion microscopy, soft X-ray tomography, electron microscopy, and random walk simulations to analyze the kinetics of host chromatin redistribution and capsid localization relative to their egress site at the nuclear envelope. Our data demonstrated a gradual increase in chromatin marginalization, and the kinetics of chromatin smoothening arou…
Transportation Assessment in Simulated Curved Canals after preparation with Twisted File Adaptive and BT-Race instruments.
2017
BACKGROUND This study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. MATERIAL AND METHODS Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and d…
Effects of in-office bleaching on human enamel and dentin. Morphological and mineral changes
2017
Abstract Background The effects of HP-based products upon dental enamel and dentin are inconclusive. Aim To evaluate changes in micromorphology and composition of calcium (Ca) and phosphate (P) in enamel and dentin after the application of 37.5% hydrogen peroxide (HP) and 35% carbamide peroxide (CP) Methods Crowns of 20 human teeth were divided in two halves. One half was used as control specimen and the other as experimental specimen. The control specimens were kept in artificial saliva, and the experimental specimens were divided into four groups (n = 5 each): group 1 (enamel HP for 45 min); group 2 (dentin HP for 45 min); group 3 (enamel CP for 90 min); and group 4 (dentin CP for 90 min)…
Influence of the Fabrication Accuracy of Hot-Embossed PCL Scaffolds on Cell Growths
2020
Polycaprolactone (PCL) is a biocompatible and biodegradable polymer widely used for the realization of 3D scaffold for tissue engineering applications. The hot embossing technique (HE) allows the obtainment of PCL scaffolds with a regular array of micro pillars on their surface. The main drawback affecting this kind of micro fabrication process is that such structural superficial details can be damaged when detaching the replica from the mold. Therefore, the present study has focused on the optimization of the HE processes through the development of an analytical model for the prediction of the demolding force as a function of temperature. This model allowed calculating the minimum demoldin…
Fast Inertia-Free Volumetric Light-Sheet Microscope
2017
Fast noninvasive three-dimensional (3D) imag-ing is crucial for quantitatively studying highly dynamic events ranging from flow cytometry to developmental biology. Light-sheet microscopy has emerged as the tool-of-choice for 3D characterization of rapidly evolving systems. However, to obtain a 3D image, either the sample or parts of the microscope are moved, limiting the acquisition speed. Here, we propose a novel inertia-free light-sheet-based scheme for volumetric imaging at high temporal resolution. Our approach comprises a novel combination of an acousto-optic scanner to produce tailored illumination and an acoustic-optofluidic lens, placed in the detection path to provide extended dept…
Guanosine-5'-Monophosphate Polyamine Hybrid Hydrogels: Enhanced Gel Strength Probed by z-Spectroscopy.
2017
The self-assembling tendencies of guanosine-5'-monophosphate (GMP) can be drastically increased using polyamines, with potential applications in the production of biocompatible smart materials, as well as for the design of anti-tumoral drugs based on G-quadruplex stabilization. Results from scanning electron microscopy (SEM), wide angle X-ray scattering (WAXS), rheology and nuclear magnetic resonance (NMR) z-spectroscopy studies are presented.