NB PLC and Software Defined Networking for Smart Grid Applications
2017
During the last years, the installation of Distributed Energy Resources (DERs) and the expected diffusion of Electrical Vehicles (EVs), is increasing the complexity of the distribution grid, making the management of the grid operated by Distribution System Operators (DSOs) more difficult. The Smart Grid approach tries to provide a response to these troubles, by means of a strong interaction between the power grid and Information and Communication Technology (ICT) infrastructures. The drawback of this approach is an increase in the management effort of the ICT infrastructures, for which the DSO are not prepared. Software Defined Networking (SDN) is an approach developed to manage complex ICT…
Medium Voltage Smart Grid: Experimental Analysis of Secondary Substation Narrow Band Power Line Communication
2013
This paper is focused on the possibility of employing narrow band power line communication (PLC) in medium voltage (MV) distribution networks. The topic is investigated by means of both simulations and experimental tests, which were carried out in the distribution network of Ustica Island. In detail, a two-way MV communication was tested between two secondary substations connected by an MV cable power line. Each substation has a by-pass connection at MV bus-bars and an MV/LV oil filled power transformer. In this paper, the MV and the PLC systems under test are described and the experimental tests are presented, which were carried out to evaluate the parameters of the simulation model. The a…
Experimental characterization of a wind generator prototype for sustainable small wind farms
2016
This paper presents the experimental characterization of a wind turbine prototype used for micro wind farms. The proposed prototype, whose advantages can be summarized in versatility of application, low noise and compactness, can generate 1 kW of rated power for a wind speed equal to 4 m/s. The tests here reported and carried out by means of an experimental test bench confirm that the prototype is well designed and adequate for the purpose of its application.
The metrological characterization of the static meters for reactive energy in the presence of harmonic distortion
2007
For the electricity metering for billing purposes in distribution systems, the static meters are substituting the traditional inductive meters. Thus, the evaluation of the performances of such equipments is required, also in the presence of disturbances affecting the power systems. With respect to this, this paper analyzes the main aspects related to the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Particular attention is given to the reference standard meters, that are not considered by the actual in-force Standards. The analysis is supported by several experimental tests.
Disturbing Load Detection in Three-Wire and Four-Wire Systems Based on Novel Nonactive Powers From IEEE 1459-2000
2010
This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems, both three-wire and four-wire. It is based on the IEEE Std. 1459-2000 effective apparent power resolution, and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In this paper, the formulation of the novel approach is given, and its effectiveness is discussed by means of several simulation tests, which were carried out on a simple test system.
A virtual instrument for the measurement of IEEE Std 1459-2000 power quantities
2006
In this paper, the authors present a PC-based instrument for the measurement of electrical-power quantities defined in IEEE Std. 1459. The instrument is based on a time-domain technique for the detection of the fundamental and harmonic components of voltages and currents. The time-domain strategy was originally developed by the authors for three-phase, three-wire systems. In that paper, the strategy had been extended to both three-phase, four-wire and single-phase systems. Simulation tests were carried out to assess the uncertainty contribution of the proposed strategy in the absence of the measurement transducers. Moreover, the accuracy of the PC-based instrument with its transducers was e…
An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…
A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000
2010
In this paper, a novel single-point strategy is proposed for the detection of the harmonic sources in power systems. The method is an improvement of a strategy previously proposed by the authors; it is developed from the IEEE Std 1459-2000 approach and it can be entirely implemented in the time domain, thus simplifying the measurement system. The effectiveness of the proposed method is evaluated by introducing simple decision-making rules and by taking the presence of the measurement transducers into account. Several simulations and experimental tests are presented, showing that the enhanced strategy is able to give an useful information on the detection of the dominant harmonic source upst…
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.