Search results for "Nuclear magnetic resonance"
showing 10 items of 1743 documents
Revealing Anisotropy in a Paul Trap Through Berry Phase
2006
When an ion confined in an anisotropic bidimensional Paul trap is subjected to a laser beam oriented along an arbitrary direction, the interaction between its electronic and vibrational degrees of freedom is described by a time-dependent Hamiltonian model as a consequence of the lack of symmetry. Appropriately choosing the laser frequency, the Hamiltonian model turns out to be sinusoidally oscillating at the difference between the proper frequencies of the center of mass of the ion. Thus, if the anisotropy of the trap is sufficiently small, the evolution of the system can be considered as adiabatic. In the context of this physical situation we have calculated the Berry phase acquired in a c…
Diversity in Itraconazole Cocrystals with Aliphatic Dicarboxylic Acids of Varying Chain Length
2013
The cocrystal formation potential of itraconazole, a potent antifungal drug, with C2–C10 aliphatic dicarboxylic acids has been investigated. Using two experimental screening techniques (solvent-assisted grinding and evaporation-based crystallization), the cocrystals of itraconazole with C2–C7 dicarboxylic acids have been successfully synthesized and characterized by powder X-ray diffraction, solid state nuclear magnetic resonance, Raman spectroscopy, and thermal analysis. The characterized multicomponent compounds include anhydrous cocrystals (malonic, succinic, glutaric, and pimelic acids), a cocrystal hydrate (adipic acid), and cocrystal solvates with acetone and tetrahydrofuran (oxalic a…
Reflection anisotropy spectroscopy of decanethiol adsorbed at Au(110)/liquid interfaces
2008
Reflection Anisotropy Spectroscopy (RAS) has been used to monitor the adsorption of decanethiol as a function of coverage on the Au(110)/ethanol interface. The coverage saturates after 60 minutes for a solution of 0.5 µM. It is found that the RAS observed after 30 minutes can be represented as a linear sum of the RAS observed after 15 minutes and after saturation coverage. This implies that the molecule does not change its orientation as function of coverage. (© 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?
1996
A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence o…
Repeatability of patellar cartilage thickness patterns in the living, using a fat-suppressed magnetic resonance imaging sequence with short acquisiti…
1998
A fast, reproducible, and noninvasive method is required for quantifying cartilage thickness clinically and for studying the deformation of articular cartilage during and after mechanical loading in vivo. The objective of the current investigation was to test the repeatability of regional distribution patterns of patellar cartilage thickness in the living on the basis of a fat-suppressed magnetic resonance imaging sequence with a short acquisition time and three-dimensional digital data processing. The knees of eight healthy volunteers were transversally imaged with a fat-suppressed FLASH-3D (fast low angle shot) sequence (acquisition time: 4 minutes and 10 seconds). In each case, the joint…
Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.
2002
Purpose To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. Materials and Methods First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/α = 2.6 msec/1.4 msec/55°) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP …
Cellular-free magnesium depletion in brain and muscle of normal and preeclamptic pregnancy: A nuclear magnetic resonance spectroscopic study
2004
Preeclampsia is a pregnancy disorder of unknown origin, characterized by vasospasm, elevated blood pressure, and increased neuromuscular irritability, features common to syndromes of magnesium deficiency. Evidence of serum and ionized magnesium metabolism disturbances have been observed in women with preeclampsia. This and the therapeutic utility of magnesium in preeclampsia led us to investigate the extent to which an endogenous tissue magnesium deficiency might be present in and contribute to its pathophysiology. We used 31 P nuclear magnetic resonance spectroscopy to noninvasively measure in situ intracellular-free magnesium levels in brain and skeletal muscle of fasting nonpregnant wom…
Metabolite identification in human liver needle biopsies by high-resolution magic angle spinning1H NMR spectroscopy
2006
High-resolution magic angle spinning (HR-MAS) 1 H NMR spectroscopy of intact human liver needle biopsies has not been previously reported. HR-MAS NMR spectra collected on 17 specimens with tissue amounts between � 0.5 and 12 mg showed very good spectral resolution and signal-to-noise ratios. One-dimensional 1 H spectra revealed many intense signals corresponding to cellular metabolites. In addition, some high molecular weight metabolites, such as glycogen and mobile fatty acids, could be observed in some spectra. Resonance assignments for 22 metabolites were obtained by combining the analysis of three different types of 1D 1 H spectral editing, such as T2 filtering or the nuclear Overhauser…
The relative contribution to the plantar-flexor torque of the soleus motor units activated by the H reflex and M response in humans.
2000
Abstract This study proposes a method of quantifying the relative contribution to the plantar-flexor torque of soleus H and M responses evoked by tibial nerve stimulation. For ten subjects, the amplitude of the twitch produced by the H wave was plotted against the corresponding potential, for stimuli producing H without M (i.e. in the ascending portion of the H-recruitment curve). It was then assumed that the contribution of H to twitches produced by M plus H was similar for similar H waves on the curve-descending portion. Hence, the contribution of M was estimated, for the range of M waves including those accompanying H max . The estimated mechanical contributions of H and M wave increase …
COMPARISON OF T-1 ESTIMATION TECHNIQUES IN CARDIAC MRI
1994
International audience; Abstract: We have shown that the use of a simple combination of inversion recovery/spin-echo (IR/SE) sequences provides undeniably superior precision in quantitative in vivo myocardium T-1 estimation than the standard multiple spin-echo approach. On a group of 25 healthy subjects, the T-1 dispersion was, respectively, 3.8% for the IR/SE combination and 19.6% for the best SE pair combination. Moreover, repeated measurements were carried out on seven of the volunteers in order to assess T-1 reproducibility. The mean intra-individual T-1 precision was found to be 2.8% for the IR/SE pair and 20.0% for the best SE pair. The in vivo imaging work was supported and corrobora…