Search results for "Optometry"
showing 10 items of 812 documents
Age-related changes in the human visual system and prevalence of refractive conditions in patients attending an eye clinic.
2008
PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descriptive values for each parameter and the correlations with age and between different parameters were calculated. Vectorial components of refraction, including blur, were also derived from clinical refractive data and then analyzed. RESULTS: Several parameters changed significantly with …
Genome-wide association study for refractive astigmatism reveals genetic co-determination with spherical equivalent refractive error: the CREAM conso…
2015
To identify genetic variants associated with refractive astigmatism in the general population, meta-analyses of genome-wide association studies were performed for: White Europeans aged at least 25 years (20 cohorts, N = 31,968); Asian subjects aged at least 25 years (7 cohorts, N = 9,295); White Europeans aged <25 years (4 cohorts, N = 5,640); and all independent individuals from the above three samples combined with a sample of Chinese subjects aged <25 years (N = 45,931). Participants were classified as cases with refractive astigmatism if the average cylinder power in their two eyes was at least 1.00 diopter and as controls otherwise. Genome-wide association analysis was carried out for …
No evidence for an association of plasma homocysteine levels and refractive error – Results from the population-based Gutenberg Health Study (GHS)
2020
Purpose There is a strong association between severe hyperhomocysteinemia and myopia. Thus we studied the hypothesis that even moderately increased levels of homocysteine (Hcy) might be a potentially treatable risk factor for myopia. Methods The Gutenberg Health Study (GHS) is a population-based, prospective, observational cohort study in Germany, including 15,010 participants aged between 35 and 74 at recruitment. The baseline examination was conducted from 2007–2012. Refraction was measured using autorefraction (HARK 599, Carl Zeiss AG, Jena, Germany). Hcy was measured by an immunoassay. We included only phakic participants without a history of corneal surgery or corneal laser treatment. …
Characteristics and pathologies of the vitreo‐macular interface—results from the Gutenberg Health Study
2019
Purpose We aimed to determine the prevalence of characteristics and pathologies of the vitreo-macular interface within the general population. Methods The Gutenberg Health Study is a population-based study in Germany, including an ophthalmological examination with refraction, biometry and optical coherence tomography (OCT) imaging. Characteristics of the vitreo-macular interface were graded on volume scans including visibility of an epiretinal membrane, full-thickness macular hole, lamellar hole and pseudohole. Overall and age-specific prevalences including 95% confidence intervals [95%-CI] were calculated. Association analyses were conducted to determine systemic and ocular factors that ar…
Genetic variants associated with human eye size are distinct from those conferring susceptibility to myopia
2021
Purpose: Emmetropization requires coordinated scaling of the major ocular components, corneal curvature and axial length. This coordination is achieved in part through a shared set of genetic variants that regulate eye size. Poorly coordinated scaling of corneal curvature and axial length results in refractive error. We tested the hypothesis that genetic variants regulating eye size in emmetropic eyes are distinct from those conferring susceptibility to refractive error.Methods: A genome-wide association study (GWAS) for corneal curvature in 22,180 adult emmetropic individuals was performed as a proxy for a GWAS for eye size. A polygenic score created using lead GWAS variants was tested for…
Relative Peripheral Myopia Induced by Fractal Contact Lenses
2018
[EN] Purpose: To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. Materials and Methods: This study involved 26 myopic subjects ranging from -0.50 D to -7.00 D. FCLs prototypes were custom-manufactured and characterized. Corneal topographies were taken in order to assess correlations between corneal asphericity and lens decentration. Two-dimensional RPREs were measured with an open-field autorefractor at 67 points, covering the central 60 x 30 degrees of the visual field. The bidimensional RPRE vector components: M, J(0) and J(45) of the difference between the values obtain…
Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses
2013
Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…
Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens
2009
Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …
Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.
2007
To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.In this prospective study, 150 eyes of 75 consecutive patients who had bilateral CLE with implantation of an AcrySof ReSTOR Natural IOL (Alcon) were evaluated. The eyes were divided into 2 groups: myopia and hyperopia. Residual refractive errors were analyzed using vector analysis. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected distance near visual acuity, and best distance-corrected near visual a…
Foldable toric intraocular lens for astigmatism correction in cataract patients.
2007
PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…