Analytical capabilities of high performance liquid chromatography – Atmospheric pressure photoionization – Orbitrap mass spectrometry (HPLC-APPI-Orbi…

2015

A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, …

AnalyteChromatographyAtmospheric pressureChemistryAnalytical chemistryRepeatabilityMass spectrometryOrbitrapBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrylaw.inventionPolybrominated diphenyl ethersCertified reference materialslawEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Procedure for automated background correction in flow systems with infrared spectroscopic detection and changing liquid-phase composition

2009

This paper describes a partial least squares (PLS) based automatic procedure to correct for changes in the spectral contribution of the solvent or solvent mixtures from solute spectra recorded in these solvents. The procedure was developed for successful on-line Fourier transform infrared (FT-IR) detection in gradient high-performance liquid chromatography (HPLC) separations. It requires a reference FT-IR data set containing all possible combinations of the expected variation in solvent composition. Furthermore, a spectral region ( A) in these spectra is required where the solvents show absorption but the analytes do not. This is the case for the system ACN:H2O, an often-applied solvent mi…

AnalyteChromatographyChemistryAnalytical chemistryInfrared spectroscopyMass spectrometryHigh-performance liquid chromatographyChemometricssymbols.namesakeFourier transformColumn chromatographysymbolsFourier transform infrared spectroscopyInstrumentationSpectroscopy
researchProduct

In-tube solid-phase microextraction-capillary liquid chromatography as a solution for the screening analysis of organophosphorus pesticides in untrea…

2006

This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysi…

AnalyteChromatographyChemistryCapillary actionOrganic ChemistryAnalytical chemistryWaterGeneral Medicineengineering.materialEnvironmentSolid-phase microextractionBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryNonylphenolchemistry.chemical_compoundPolybrominated diphenyl ethersOrganophosphorus CompoundsCoatingengineeringSample preparationPesticidesSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of chromatography. A
researchProduct

Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…

2006

Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…

AnalyteChromatographyChemistryElectrospray ionizationOrganic ChemistryReproducibility of ResultsGeneral MedicineKidneySensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnti-Bacterial AgentsAnalytical ChemistryLiverCalibrationAnimalsmedia_common.cataloged_instanceSample preparationEuropean UnionMacrolidesSolid phase extractionEuropean unionQuantitative analysis (chemistry)Antibacterial agentmedia_commonJournal of Chromatography A
researchProduct

Column-switching techniques for high-performance liquid chromatography of drugs in biological samples.

1993

In recent years, an increasing number of publications have demonstrated the potential of column-switching techniques for the chromatographic separation, determination and preparative isolation of analytes from biological matrices. Column-switching systems greatly facilitate drug analysis, by on-line sample clean-up and trace enrichment, or by improving the analytical separative process. In this paper, the main applications of column-switching techniques to drug analysis in biological samples, are reviewed.

AnalyteChromatographyChemistryGeneral ChemistryHigh-performance liquid chromatographyBiological materialsChromatographic separationColumn chromatographyPharmaceutical PreparationsAnimalsHumansColumn switchingDrug analysisQuantitative analysis (chemistry)Chromatography High Pressure LiquidJournal of chromatography
researchProduct

Environmentally friendly LC for the simultaneous determination of ascorbic acid and its derivatives in skin-whitening cosmetics

2008

Ascorbic acid (AA), also known as vitamin C, is a very popular skin-whitening agent used in cosmetics. However, the use of AA (and also its sodium or magnesium salts) in cosmetic products is limited owing to its labile oxidative properties. In order to avoid its early degradation, different derivatives have been designed, such as ascorbyl phosphate (APH; as magnesium or sodium salts) and ascorbyl palmitate (AP), and more recently the ascorbyl glucoside (AG). Bearing in mind that all these chemicals in skin-whitening cosmetic products must be determined in order to control the efficacy of such products, this paper focuses on developing a wide-ranging LC analytical method able to determine th…

AnalyteChromatographyChemistryMagnesiumSodiummedia_common.quotation_subjectAscorbyl palmitatechemistry.chemical_elementFiltration and SeparationAscorbic AcidCosmeticsReversed-phase chromatographyReference StandardsAscorbic acidSensitivity and SpecificityCosmeticsHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundSpectrophotometry UltravioletChromatography Liquidmedia_commonJournal of Separation Science
researchProduct

Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid…

2002

A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte pe…

AnalyteChromatographyClinical BiochemistryExtraction (chemistry)RetinolReproducibility of ResultsTocopherolsLiterCell BiologyGeneral MedicineBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundSpectrometry FluorescencechemistryLiquid–liquid extractionHumansSample preparationAll trans retinolVitamin AChromatography High Pressure LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Generalised H-point standard addition method for the isolation of the analyte signal from the sample signal when coelution of unknown compounds occur…

1999

The generalised H-point standard addition method (GHPSAM) is proposed for isolating the analytical signal of an analyte from the signal of an unknown sample. Samples containing two and three coeluting compounds have been analysed. The accuracy of the predictions depends on the shape of the analyte and interferent spectra but not on the degree of chromatographic overlap. This methodology involves the location of linear intervals for the unknown interference spectrum from the spectrum of the sample. Once the linear interval has been found the selection of three wavelengths within the interval will allow the cancellation of the signal of the unknown interferent. The method has been applied to …

AnalyteInternal standardChromatographyChemistryOrganic ChemistryAmphetaminesAnalytical chemistryGeneral MedicineBiochemistrySample (graphics)SignalHigh-performance liquid chromatographyAnalytical ChemistryInterference (communication)PhenolsStandard additionSpectrophotometry UltravioletDiureticsQuantitative analysis (chemistry)Chromatography LiquidJournal of chromatography. A
researchProduct

Target analysis and retrospective screening of mycotoxins and pharmacologically active substances in milk using an ultra-high-performance liquid chro…

2020

Milk is a nutritious food suitable for infants and adults, and it plays an important role in the human diet. However, it may also be a vehicle for food contaminants. In this report, we developed a method using ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-Q-Exactive Orbitrap HRMS; Thermo Fisher Scientific, Waltham, MA) for simultaneous identification of target pharmacologically active substances and mycotoxins in milk. We also used the Q-Orbitrap operating in full scan mode to identify other possible drugs and microbial metabolites that occurred in samples. Fifty-six commercially available milk samples from the Italian market were analyze…

AnalyteQuEChERSTarget analysisFood ContaminationOrbitrapMass spectrometryQuechersretrospective analysiMass Spectrometrylaw.inventionmycotoxin03 medical and health scienceschemistry.chemical_compoundlawGeneticsAnimalsMycotoxinChromatography High Pressure Liquid030304 developmental biologyRetrospective Studies0303 health sciencesChromatographyultra-high-performance liquid chromatography/high-resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS)pharmacologically active substanceChemistry0402 animal and dairy science04 agricultural and veterinary sciencesContaminationMycotoxins040201 dairy & animal scienceMilkItalyAnimal Science and ZoologyFood ScienceFood contaminantJournal of dairy science
researchProduct

Science based calibration for the extraction of 'analyte-specific' HPLC-DAD chromatograms in environmental analysis

2010

Multivariate science based calibration (SBC) has been applied to the resolution of overlapped peaks in liquid chromatography with diode array detection (LC-DAD). Complex river water samples spiked with 11 pharmaceutical substances resulted in poorly resolved chromatograms containing additional peaks from interfering matrix compounds and a change in the background absorbance due to the mobile phase gradient. Applying the present multivariate approach it was possible to resolve all 11 analytes from overlapping peaks, obtaining linear calibration lines (R2 > 0.96). Recovery percentages on spiked samples ranged between 74.6 and 113.5%, which are quite satisfactory taking into account the low co…

AnalyteResolution (mass spectrometry)Adrenergic beta-AntagonistsStatistics as TopicAnalytical chemistryEnvironmentHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)AbsorbanceRiversSCIENCE BASED CALIBRATIONSample preparationLeast-Squares AnalysisElectrodesChromatography High Pressure LiquidAnalgesicsENVIRONMENTAL ANALYSISChromatographyChemistryOtras Ciencias QuímicasExtraction (chemistry)Ciencias QuímicasDrug ResiduesStandard curveHIGH PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION (HPLC-DAD)CalibrationMultivariate AnalysisEnvironmental PollutantsCIENCIAS NATURALES Y EXACTAS