Search results for "Photoplethysmogram"

showing 10 items of 84 documents

A validity and reliability study of Conditional Entropy Measures of Pulse Rate Variability

2019

In this work, we present the feasibility to use a simpler methodological approach for the assessment of the short-term complexity of Heart Rate Variability (HRV). Specifically, we propose to exploit Pulse Rate Variability (PRV) recorded through photoplethysmography in place of HRV measured from the ECG, and to compute complexity via a linear Gaussian approximation in place of the standard model-free methods (e.g., nearest neighbor entropy estimates) usually applied to HRV. Linear PRV-based and model-free HRV-based complexity measures were compared via statistical tests, correlation analysis and Bland-Altman plots, demonstrating an overall good agreement. These results support the applicabil…

020205 medical informaticsComputer scienceEntropy0206 medical engineeringValidity02 engineering and technologySettore ING-INF/01 - ElettronicaElectrocardiographyPulse Rate Variability (PRV)Heart RatePhotoplethysmogram0202 electrical engineering electronic engineering information engineeringHumansEntropy (information theory)Heart rate variabilityEntropy (energy dispersal)Time seriesPhotoplethysmographyEntropy (arrow of time)Statistical hypothesis testingConditional entropyEntropy (statistical thermodynamics)Reproducibility of ResultsHeart Rate Variability (HRV)020601 biomedical engineeringSettore ING-INF/06 - Bioingegneria Elettronica E InformaticacomplexityAlgorithmEntropy (order and disorder)2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
researchProduct

Portable remote photoplethysmography device for monitoring of blood volume changes with high temporal resolution

2016

The compact remote photoplethysmography device for monitoring of blood volume pulsations from human skin were developed. The prototype device comprises electronics board with twelve circullary oriented bright near-infrared LED illuminators, which are precisely controlled, high-speed video camera and battery charging circuit. Device was tested in laboratory and could be used for non-contact monitoring of human blood volume changes in palm.

0301 basic medicineHuman bloodComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONBattery (vacuum tube)Video cameraBlood volume01 natural scienceslaw.invention010309 optics03 medical and health sciences030104 developmental biologylawPhotoplethysmogram0103 physical sciencesHigh temporal resolutionbusinessComputer hardwareBiomedical engineeringVolume (compression)2016 15th Biennial Baltic Electronics Conference (BEC)
researchProduct

Optical noninvasive monitoring of skin blood pulsations

2005

Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…

AdultMaleAdolescentHeartbeatMaterials Science (miscellaneous)Pulsatile flowArterial Occlusive DiseasesBlood volumeSensitivity and SpecificityIndustrial and Manufacturing EngineeringOpticsData acquisitionArterial occlusionsHeart RatePhotoplethysmogrammedicineAnimalsHumansDiagnosis Computer-AssistedBusiness and International ManagementPhotoplethysmographySkinFrequency filteringbusiness.industryReproducibility of ResultsEquipment DesignEquipment Failure Analysismedicine.anatomical_structurePulsatile FlowVascular resistanceFemalesense organsbusinessAlgorithmsBlood Flow VelocityBiomedical engineeringApplied Optics
researchProduct

Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.

2014

Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…

AdultMalemedicine.medical_specialtyBiomedical EngineeringNormal DistributionHemodynamicsBiomaterialsInternal medicinePhotoplethysmogrammedicineHumansPhotoplethysmographyReactive hyperemiaHemodynamicsBlood flowArteriesmedicine.diseaseArterial occlusionAtomic and Molecular Physics and OpticsHealthy VolunteersElectronic Optical and Magnetic MaterialsFemoral Arterymedicine.anatomical_structureBlood pressureAnesthesiaCardiologyVascular resistanceArterial stiffnessFemaleVascular ResistanceJournal of biomedical optics
researchProduct

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Bilateral photoplethysmography studies of the leg arterial stenosis.

2005

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…

Adultmedicine.medical_specialtyPhysiologyBiomedical EngineeringBiophysicsArterial Occlusive DiseasesBlood PressurePhysiology (medical)PhotoplethysmogramInternal medicineHealthy controlmedicineOscillometryHumansPhotoplethysmographyAgedAged 80 and overPeripheral Vascular DiseasesLegArterial stenosisbusiness.industryHealthy subjectsMiddle Agedmedicine.diseaseSurgerybody regionsStenosisBlood pressuremedicine.anatomical_structureVascular resistanceCardiologybusinessPhysiological measurement
researchProduct

Photoplethysmography system for blood pulsation detection in unloaded artery conditions

2012

Photoplethysmography (PPG) is an optical method of blood pulsation recording and has been extensively studied for decades. Recently PPG is widely used in the medical equipment for patient monitoring and in laboratories for research and physiological studies. In spite of the technological progress in the field of medical equipment, there are no generally accepted standards for clinical PPG measurements up to date. One of the most important factors affecting PPG waveform is the contact pressure between tissue and PPG probe. The aim of the current study was to develop and evaluate a system for software-assisted PPG signal acquisition from the unloaded artery. Novel PPG waveform derived Optimal…

Blood pressureTransmural pressuremedicine.anatomical_structureComputer scienceRemote patient monitoringPhotoplethysmogrammedicinePlethysmographWaveformsense organsArteryBiomedical engineeringSPIE Proceedings
researchProduct

LASCA and PPG imaging for non-contact assessment of skin blood supply

2013

Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging (LDPI). Photoplethysmography (PPG) is well known technique for assessment of skin blood pulsations that can be related to blood flow. In recent years several studies have been done on development of non-contact PPG imaging (PPGI). LASCA and PPGI techniques are simpler and cheaper compared with LDPI. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new i…

CMOS sensorPixelComputer scienceSkin blood flowbusiness.industryColor imageBlood flowArterial occlusionsymbols.namesakeSpeckle patternOpticsPhotoplethysmogramsymbolsBlood supplybusinessDoppler effectBiomedical engineeringMedical Imaging 2013: Physics of Medical Imaging
researchProduct

The blood perfusion mapping in the human skin by photoplethysmography imaging

2010

A CMOS camera-based imaging photoplethysmographic (PPGI) system is described to detect the blood pulsations in tissue. Attention of PPGI is drawn to the potential applications in visualized blood perfusion. Intensity variations of three wavelengths (620 nm, 520 nm and 432 nm) were detected and analyzed in each pixel of image. To obtain a twodimensional mapping of the dermal perfusion measurement, custom image-processing software has been developed. The high-resolution PPGI images were derived from human fingers (transmission mode) and face (reflection mode), evaluated at three wavelengths. The newly developed system can be usable in skin blood perfusion monitoring for clinical applications.

CMOS sensorPixelbusiness.industryPhotoplethysmogramMedicineHuman skinbusinessPerfusionBiomedical engineeringIntensity (physics)
researchProduct