Search results for "Polyethylene"

showing 10 items of 809 documents

Acid‐Cleavable Poly(ethylene glycol) Hydrogels Displaying Protein Release at pH 5

2020

Abstract PEG is the gold standard polymer for pharmaceutical applications, however it lacks degradability. Degradation under physiologically relevant pH as present in endolysosomes, cancerous and inflammatory tissues is crucial for many areas. The authors present anionic ring‐opening copolymerization of ethylene oxide with 3,4‐epoxy‐1‐butene (EPB) and subsequent modification to introduce acid‐degradable vinyl ether groups as well as methacrylate (MA) units, enabling radical cross‐linking. Copolymers with different molar ratios of EPB, molecular weights (M n) up to 10 000 g mol−1 and narrow dispersities (Đ<1.05) were prepared. Both the P(EG‐co‐isoEPB)MA copolymer and the hydrogels showed pH‐…

540 Chemistry and allied sciencesVinyl CompoundsBiocompatible MaterialsDegree of polymerization010402 general chemistry01 natural sciencesCatalysisPolyethylene GlycolsPolymerizationchemistry.chemical_compoundHydrolysisPolymer chemistryPEG ratioCopolymermedicinehydrogelsPolymer Technologieschemistry.chemical_classificationFull PaperEthylene oxide010405 organic chemistryHydrolysisOrganic ChemistryBiochemistry and Molecular BiologyProteinsprotein releaseHydrogelsGeneral ChemistryPolymerFull PapersHydrogen-Ion ConcentrationVinyl etherPolymerteknologiPEG0104 chemical sciencescopolymerizationchemistry540 Chemiedrug deliverySelf-healing hydrogelsMethacrylatesBiokemi och molekylärbiologimedicine.drugChemistry – A European Journal
researchProduct

Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…

2000

The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…

Accuracy and precisionGeneral Chemical EngineeringAnalytical chemistrychemistry.chemical_elementGeneral ChemistryIsotope dilutionPolyethyleneMass spectrometryMatrix (chemical analysis)Chromiumchemistry.chemical_compoundThird phasechemistrySafety Risk Reliability and QualityInstrumentationInductively coupled plasma mass spectrometryAccreditation and Quality Assurance
researchProduct

Assisted baseline subtraction in complex chromatograms using the BEADS algorithm.

2017

The data processing step of complex signals in high-performance liquid chromatography may constitute a bottleneck to obtain significant information from chromatograms. Data pre-processing should be preferably done with little (or no) user supervision, for a maximal benefit and highest speed. In this work, a tool for the configuration of a state-of-the-art baseline subtraction algorithm, called BEADS (Baseline Estimation And Denoising using Sparsity) is developed and verified. A quality criterion based on the measurement of the autocorrelation level was designed to select the most suitable working parameters to obtain the best baseline. The use of a log transformation of the signal attenuate…

AcetonitrilesNoise reduction02 engineering and technology01 natural sciencesBiochemistrySignalAnalytical ChemistryPolyethylene GlycolsBaseline (configuration management)Chromatography High Pressure LiquidData processingElectronic Data ProcessingChromatographyElutionChemistry010401 analytical chemistryOrganic ChemistryAutocorrelationProcess (computing)General Medicine021001 nanoscience & nanotechnologySample (graphics)0104 chemical sciences0210 nano-technologyAlgorithmAlgorithmsJournal of chromatography. A
researchProduct

Visceral adiposity index is associated with histological findings and high viral load in patients with chronic hepatitis C due to genotype 1.

2010

Metabolic factors have been associated with liver damage in patients with genotype 1 chronic hepatitis C (G1 CHC). We tested visceral adiposity index (VAI), a new marker of adipose dysfunction in G1 CHC, patients to assess its association with host and viral factors and its link to both histological findings and sustained virological response (SVR). Two hundred thirtysix consecutive G1 CHC patients were evaluated by way of liver biopsy and anthropometric and metabolic measurements, including insulin resistance (IR), homeostasis model assessment (HOMA), and VAI using waist circumference, body mass index, triglycerides, and highdensity lipoprotein cholesterol. All biopsies were scored by one …

AdultBlood GlucoseMalemedicine.medical_specialtyPathologyAlcohol DrinkingGenotypeInterferon alpha-2Intra-Abdominal FatGastroenterologyAntiviral AgentsBody Mass IndexPolyethylene GlycolsInsulin resistanceInternal medicineDiabetes mellitusmedicineHumansHepatologymedicine.diagnostic_testbusiness.industryCholesterol HDLInterferon-alphaAlanine TransaminaseHepatitis CHepatologyHepatitis C ChronicMiddle AgedViral Loadmedicine.diseaseRecombinant ProteinsFatty LiverDiabetes Mellitus Type 2Liver biopsyHypertensionRNA ViralFemaleSteatosisWaist CircumferencebusinessViral loadBody mass indexHepatology (Baltimore, Md.)
researchProduct

Inhibition of Fcγ Receptors in the Plasma of Subjects with Down's Syndrome

1993

Abstract Subjects with Down's syndrome have several immunological abnormalities. We examined the sera of 29 subjects with Down's syndrome for the presence of Fcγ receptor blocking and for the presence of anti-ssDNA antibodies by EA rosette inhibition. Fifty-five percent of Down subjects had levels of inhibition above the upper limit of normality in comparison to 7% of normal controls. The finding that after polyethylene glycol precipitation of selected sera giving high levels of EA rosette inhibition there was a reduction or a disappearance of the EA rosette inhibition could indicate that the blocking factors detected behaved as immune complexes. Since almost all subjects with anti-ssDNA an…

AdultDown syndromeErythrocytesRosette FormationAdolescentImmunologyDNA Single-StrandedAntigen-Antibody ComplexAntibodiesPolyethylene GlycolsPathology and Forensic MedicinePathogenesisImmune systemmedicineAnimalsChemical PrecipitationHumansImmunology and AllergyLymphocytesChildReceptorbiologyRosette (schizont appearance)Receptors IgGAutoantibodyInfantmedicine.diseaseImmunoglobulin AImmunoglobulin MChild PreschoolImmunoglobulin GImmunologybiology.proteinDown SyndromeAntibodyTrisomyChickensClinical Immunology and Immunopathology
researchProduct

FibroTest is an independent predictor of virologic response in chronic hepatitis C patients retreated with pegylated interferon alfa-2b and ribavirin…

2010

EPIC-3 is a prospective, international study that has demonstrated the efficacy of PEG-IFN alfa-2b plus weight-based ribavirin in patients with chronic hepatitis C and significant fibrosis who previously failed any interferon-alfa/ribavirin therapy. The aim of the present study was to assess FibroTest (FT), a validated non-invasive marker of fibrosis in treatment-naive patients, as a possible alternative to biopsy as the baseline predictor of subsequent early virologic (EVR) and sustained virologic response (SVR) in previously treated patients.Of 2312 patients enrolled, 1459 had an available baseline FT, biopsy, and complete data. Uni- (UV) and multi-variable (MV) analyses were performed us…

AdultLiver CirrhosisMaleBiopsyFibrotestInterferon-alphaAlanine TransaminaseHepatitis C ChronicInterferon alpha-2Middle AgedPrognosisRecombinant ProteinsPolyethylene GlycolsFatty LiverRibavirinHumansDrug Therapy CombinationFemaleProspective Studies
researchProduct

Raltegravir Pharmacokinetics in Patients on Asunaprevir-Daclatasvir.

2015

ABSTRACT Raltegravir pharmacokinetics was studied in 20 patients included in the ANRS HC30 QUADRIH Study before and after addition of anti-hepatitis C virus (anti-HCV) quadritherapy, including pegylated-interferon–ribavirin and asunaprevir plus daclatasvir. Raltegravir pharmacokinetic parameters remained unchanged whether administered on or off anti-HCV therapy. In addition, concentrations of raltegravir, asunaprevir, and daclatasvir were not affected by liver cirrhosis. These data suggest that in human immunodeficiency virus (HIV)-HCV-coinfected patients, whether cirrhotic or not, asunaprevir and daclatasvir could be administered safely with raltegravir.

AdultLiver CirrhosisMaleDaclatasvirPyrrolidinesAlpha interferonHIV InfectionsHepacivirusPharmacologyAntiviral AgentsRaltegravir PotassiumPolyethylene Glycolschemistry.chemical_compoundPharmacokineticsRaltegravir PotassiumRibavirinMedicineHumansPharmacology (medical)PharmacologySulfonamidesbusiness.industryCoinfectionRibavirinImidazolesvirus diseasesInterferon-alphaValineHepatitis CHepatitis C ChronicMiddle AgedRaltegravirmedicine.diseaseIsoquinolinesdigestive system diseasesRecombinant ProteinsInfectious DiseaseschemistryLiverHIV-1AsunaprevirDrug Therapy CombinationFemaleCarbamatesbusinessmedicine.drugAntimicrobial agents and chemotherapy
researchProduct

A Randomized, Blinded, Prospective Trial to Compare the Safety and Efficacy of Three Bowel-Cleansing Solutions for Colonoscopy (HSG-01*)

2003

BACKGROUND AND STUDY AIMS There are conflicting data regarding the optimal bowel preparation for colonoscopy. This study was carried out to compare the efficacy, safety, and tolerability of three widely used bowel lavage solutions: the standard polyethylene glycol-electrolyte solution based on the GoLytely formulation (PEG-EL1; Klean-Prep); a sulphate-free PEG-EL solution based on the NuLytely formulation (PEG-EL2, Endofalk); and a sodium phosphate preparation (NaP, Fleet Phospho-Soda). PATIENT AND METHODS A total of 185 consecutive patients scheduled for elective colonoscopy were prospectively randomly assigned to undergo pre-colonoscopic bowel cleansing with either 4 l of PEG-EL1 (n=64), …

AdultMaleAbdominal painmedicine.medical_specialtyRandomizationAdolescentNauseaRectumColonoscopyPhosphatesPolyethylene GlycolsElectrolytesPatient satisfactionmedicineHumansAscending colonProspective StudiesAgedmedicine.diagnostic_testCatharticsbusiness.industryGastroenterologyColonoscopyMiddle AgedSurgerySolutionsmedicine.anatomical_structureTolerabilityFemalemedicine.symptombusinessEndoscopy
researchProduct

Peginterferon-Α_2B plus ribavirin is more effective than peginterferon-Α_2A plus ribavirin in menopausal women with chronic hepatitis C.

2012

Under-enrolment of women to randomized clinical trials, including chronic hepatitis C, has long been recognized. The aim of this study was to identify factors predictive of sustained virological response (SVR) to PEG IFN/Ribavirin antiviral therapy in relation to gender and reproductive status of female patients involved. Seven hundred and forty-six treatment-naïve patients (431 men, 315 women) treated with Peg-IFNα-2a (180 μg/week) or Peg-IFNα-2b (1.5 μg/kg/week) plus ribavirin (800–1400 mg/day) for 24 or 48 weeks were studied between 2006 and 2010. Differences in SVR rate, overall and by gender were assessed after adjustment and propensity score matching. SVR was obtained in 44.2% of Peg-…

AdultMaleAdolescentInterferon alpha-2Antiviral AgentsPolyethylene GlycolsYoung AdultSex FactorsRibaviringenderHumansAgedSettore MED/12 - GastroenterologiaPeg IFNAge FactorsInterferon-alphaHepatitis C ChronicMiddle Agedcentral fat distribution cytokines metabolic syndrome pharmacokinetics sustained virological responseRecombinant ProteinsTreatment OutcomeDrug Therapy CombinationFemaleEpatite HCV; Peg IFN; genderMenopauseSettore SECS-S/01 - StatisticaEpatite HCVJournal of viral hepatitis
researchProduct

Magnetic molecularly imprinted polymers for the selective determination of cocaine by ion mobility spectrometry

2018

Abstract Magnetic molecularly imprinted polymers (MMIPs) were prepared for cocaine recognition by bulk polymerization in the presence of magnetic nanoparticles (MNPs). Two reagents (polyethylene glycol (PEG) and 3-(trimethoxysilyl)propyl methacrylate (V)) were used for MNPs modification. MMIPs were characterized and compared in terms of loading capacity, reusability, accuracy and precision for the extraction of cocaine from saliva samples. It was observed that V-MMIPs gave higher physical stability than PEG-MMIPs. Thus, V-MMIP were used for the analysis of cocaine users saliva. The developed procedure based on ion mobility spectrometry (IMS) provided limits of detection and quantification o…

AdultMaleBulk polymerizationPolymersIon-mobility spectrometry02 engineering and technologyPolyethylene glycolTandem mass spectrometryMethacrylate01 natural sciencesBiochemistryPolyethylene GlycolsAnalytical ChemistryMolecular ImprintingMagneticsYoung Adultchemistry.chemical_compoundCocaineIon Mobility SpectrometryHumansOrganosilicon CompoundsSalivaChromatography High Pressure LiquidDetection limitChromatography010401 analytical chemistryOrganic ChemistryMolecularly imprinted polymerSignal Processing Computer-AssistedGeneral Medicine021001 nanoscience & nanotechnology0104 chemical scienceschemistryMethacrylatesMagnetic nanoparticlesFemale0210 nano-technologyJournal of Chromatography A
researchProduct