Search results for "Prosthesis"
showing 10 items of 719 documents
Mid- to long-term results after bipolar radial head arthroplasty.
2009
Background Radial head arthroplasty is considered the treatment of choice for unreconstructable radial head fractures in the acute fracture situation. Although short-term results in the current literature are promising, replacement of the radial head remains controversial as long-term results are still missing. We report our 8.8-year results after treatment with a bipolar radial head prosthesis by Judet. Materials and methods In our department, 19 patients were treated with bipolar radial head arthroplasty between 1997 and 2001. Seventeen of these patients—14 men and 3 women—were examined retrospectively after 106 months (range, 78-139). Of these, 9 patients were treated primarily, 7 patien…
Sex-Related Clinical Characteristics and Outcomes of Patients Undergoing Transcatheter Edge-to-Edge Repair for Secondary Mitral Regurgitation.
2021
OBJECTIVES The authors sought to assess sex-based differences in characteristics and outcomes of patients undergoing transcatheter edge-to-edge mitral valve repair (TMVR) for secondary mitral regurgitation (SMR). BACKGROUND Subgroup analysis from the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart��Failure Patients with Functional Mitral Regurgitation) trial indicated potential sex-related differences in outcomes after TMVR. The impact of sex on results after TMVR in a real-world setting is unknown. METHODS The authors assessed clinical outcomes and echocardiographic parameters in women and men undergoing TMVR for SMR between 2008 and 2018 who were …
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
Implant supported dental rehabilitation following segmental mandibular reconstruction- quality of life outcomes of a prospective randomized trial.
2016
Abstract Purpose The primary objective of this study was to assess the difference in quality of life (QoL) in patients with dental rehabilitation using two or four implant-supported overdentures following segmental mandibulectomy defect reconstruction with fibula free flap. Material and methods This prospective, parallel designed, randomized clinical study was conducted with a 1:1 ratio. At baseline, all participants already had fibula flap reconstruction for segmental defects of the mandible and rehabilitation with conventional (non-implant supported) removable partial dentures. The participants were then randomized into two groups. Group I received implant supported overdentures on two im…
Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible.
2010
Background: Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Patients and Methods: Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of imPrimary implant stability was measured by means of RFA an…
A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report.
2009
Background: There is a lack of clinical studies on the self-aligning attachment system (Locator®; Zest Anchors, Inc. homepage, Escondido, CA, USA) for two-implant-retained overdentures in the edentulous mandible. Therefore, a comparison of the Locator with two traditional designs (a rotational gold matrix and a rubber O-ring type) in clinical 1-year use was conducted. MaterialsandMethods: From 2003 to 2007, 60 patients received two Osseotite® TG Standard implants (BIOMET 3i Implant Innovations, Palm Beach Gardens, FL, USA) in the intraforaminal area of the edentulous mandible. The implants were left unloaded for 3.5 months, randomized to three different attachment systems, and loaded throug…
Patient-centered and clinical outcomes of mandibular overdentures retained with the locator system: A prospective observational study
2017
Whether clinical or demographic variables affect the perception of treatment in terms of quality of life and satisfaction is unknown.The purpose of this prospective study was to make an evidence-based assessment of the treatment outcomes (patient- and clinically based) of locator-retained mandibular overdentures.This prospective observational study assessed patients with edentulism who had worn mandibular overdentures supported by 2 implants and retained by the locator system for at least 1 year of functional life (N=80). Medical histories were reviewed, and patients underwent oral examinations. Prosthetic clinical outcomes and patient well-being were registered using the Oral Health Impact…
Modular megaprosthesis reconstruction for oncological and non-oncological resection of the elbow joint
2016
Abstract Background Reconstruction of large bone defects around the elbow joint is surgically demanding due to sparse soft tissue coverage, complex biomechanics and the close proximity to neurovascular structures. Modular megaprostheses are established reconstruction tools for the elbow, but only small case series have been reported in the literature. Methods Thirty-six patients who underwent reconstruction of the elbow joint with a modular megaprosthesis were reviewed retrospectively. In 31 patients (86.1%), elbow replacement was performed after resection of a bone tumour, whereas five non-oncological patients (13.9%) underwent surgery because of a previous failed elbow reconstruction. Fun…
Haemodynamic predictors of a penetrating atherosclerotic ulcer rupture using fluid-structure interaction analysis
2013
We present preliminary data on the flow-induced haemodynamic and structural loads exerted on a penetrating atherosclerotic aortic ulcer (PAU). Specifically, one-way fluid-structure interaction analysis was performed on the aortic model reconstructed from a 66-year-old male patient with a PAU that evolved into an intramural haematoma and rupture of the thoracic aorta. The results show that elevated blood pressure (117 mmHg) and low flow velocity at the aortic wall (0.15 m/s(2)) occurred in the region of the PAU. We also found a low value of time-averaged wall shear stress (1.24 N/m(2)) and a high value of the temporal oscillation in the wall shear stress (oscillatory shear index = 0.13) in t…