Search results for "RESONANCE"
showing 10 items of 6625 documents
Prediction error signal correlates with fluid intelligenceand dopamine synthesis across the lifespan
2011
IntroductionFluid intelligence expresses the capacity for interpretation of novel stimuli and flexible behavioral adaptation to such cues. Phasic dopamine firing closely matches a temporal difference prediction error (PE) signal important for learning and rapid behavioral adaptation. Both fluid intelligence and dopaminergic neurotransmission decline with age. So far, no study investigated the relationship between fluid IQ, PE signal and direct measures of dopaminergic neurotransmission. Here we used a multimodal imaging approach that combines positron emission tomography and functional magnetic resonance imaging.MethodsA group of healthy controls was investigated with both 6-[18F]FluoroDOPA…
Measuring Functional Connectivity of Human Intra-Cortex Regions with Total Correlation
2021
The economy of brain organization makes the primate brain consume less energy but efficiency. The neurons densely wired each other dependent on both anatomy structure connectivity and functional connectivity. Here, I only describe functional connectivity with Functional Magnetic Resonance Imaging (fMRI) data. Most importantly, how to quantitative measure information share or separate among functional brain regions, what’s worse, fMRI data exist large dimensional problems or “curse dimensionality” [1]. However, the multivariate total correlation method can perfectly address the above problems. In this paper, two things measured with the information-theoretic technique - total correlation [2,…
New imaging procedures in thyroid-associated ophthalmopathy
1996
Lymphocytic and other mononuclear cell infiltrations of the retrobulbar space are observed in thyroid-associated ophthalmopathy (TAO). The identification of somatostatin receptors on lymphocytes has provided a rationale for receptor-imaging with the radiolabeled somatostatin analog Octreotide in TAO. Furthermore, previous investigations have shown that quantitative magnetic resonance imaging (MRI) allows non-invasive detection of acute inflammatory changes in extraocular muscles. Therefore, in patients with TAO and controls, scans of the orbits were obtained at 4h and 24h after i.v. injection of the radionuclide and orbital MRI was performed. Compared to controls, patients with TAO showed a…
Manejo perioperatorio de pacientes portadores de sistemas electrónicos implantables para el control del dolor crónico
2019
Linking immune-mediated damage to neurodegeneration in multiple sclerosis: could network-based MRI help?
2021
Abstract Inflammatory demyelination characterizes the initial stages of multiple sclerosis, while progressive axonal and neuronal loss are coexisting and significantly contribute to the long-term physical and cognitive impairment. There is an unmet need for a conceptual shift from a dualistic view of multiple sclerosis pathology, involving either inflammatory demyelination or neurodegeneration, to integrative dynamic models of brain reorganization, where, glia-neuron interactions, synaptic alterations and grey matter pathology are longitudinally envisaged at the whole-brain level. Functional and structural MRI can delineate network hallmarks for relapses, remissions or disease progression, …
Autogreffe chondrocostale pour lésion latérale ostéochondrale de la tête métacarpienne
2020
Abstract Osteochondral injuries of the metacarpal head require anatomical restoration to prevent limitations in range of motion and osteoarthritis. Osteochondral bone grafting is a viable option, especially in younger patients. Central injuries allow for different types of grafting, but when the injured area is on the lateral portion of the metacarpal head, the graft must include both a cortical and a cartilaginous portion. We present here the pearls and pitfalls in the surgical technique of chondrocostal grating from the 6th rib and an example of its use within a case of comminuted fracture of the metacarpal head. This technique provides a graft with cortical bone that allows for a stable …
Clustering Algorithms for MRI
1991
Magnetic Resonance Imaging (MRI) plays a relevant role in the design of systems for computer assisted diagnosis. MR-images are multi-dimensional in nature; physicians have to combine several perceptual information images to perform the tissue classification needed for diagnosis. Automatic clustering methods help to discriminate relevant features and to perform a preliminary segmentation of the image; it can guide the final manual classification of body-tissues. Three clustering techniques and their integration in a MRI-system are described. Their performance and accuracy was evaluated on synthetic and real image-data. A comparison of our approach with the tissue-classification done by a rad…
Classification of Schizophrenia Patients and Healthy Controls Using ICA of Complex-Valued fMRI Data and Convolutional Neural Networks
2019
Deep learning has contributed greatly to functional magnetic resonance imaging (fMRI) analysis, however, spatial maps derived from fMRI data by independent component analysis (ICA), as promising biomarkers, have rarely been directly used to perform individualized diagnosis. As such, this study proposes a novel framework combining ICA and convolutional neural network (CNN) for classifying schizophrenia patients (SZs) and healthy controls (HCs). ICA is first used to obtain components of interest which have been previously implicated in schizophrenia. Functionally informative slices of these components are then selected and labelled. CNN is finally employed to learn hierarchical diagnostic fea…
Bestimmung der myokardialen Perfusionsreserve bei KHK-Patienten mit der kontrastmittelverstärkten MRT: Ein Vergleich zwischen semiquantitativer und q…
2002
OBJECTIVE Comparison between two semiquantitative methods and a quantitative evaluation of myocardial blood flow (MBF) for assessment of myocardial perfusion reserve (MPR) in patients with CAD. MATERIAL AND METHODS 9 patients with coronary stenoses > 50 % were examined with an ECG-gated Saturation Recovery Turbo FLASH sequence by using Gd-DTPA as contrast agent (CA). The entive measurements were performed both during rest and hyperemia induced by adenosine. The up-slopes of the signal-time S(t) curves in the myocardium and left ventricular (LV) cavity were evaluated by a linear fit. MPR was calculated from the original up-slopes of the myocardial S(t) curves and from the up-slopes, which we…
Comparison of the quantitative first pass myocardial perfusion MRI with and without prospective slice tracking: Comparison between breath-hold and fr…
2010
Physiologic motion of the heart is one of the major problems of myocardial blood flow quantification using first pass perfusion-MRI method. To overcome these problems, a perfusion pulse sequence with prospective slice tracking was developed. Cardiac motion was monitored by a navigator directly positioned at heart's basis to overcome no additional underlying model calculations connecting diaphragm and cardiac motion. Additional prescans were used before the perfusion measurement to detect slice displacements caused by remaining cardiac motion between navigator and the perfusion slice readout. The pulse sequence and subsequent quantification of myocardial blood flow was tested in healthy pigs…