Search results for "Radiograph"

showing 10 items of 830 documents

Viewing patterns regarding panoramic radiographs with different pathological lesions: an eye-tracking study.

2021

Objective: The aim of this study was to examine how dental students vary their viewing patterns of panoramic radiographs during different levels of dental education. Methods: Two groups of students (total number = 48, n = 24) in different grades (second and fifth clinical semester) were compared. The second clinical semester participated twice, as during the second clinical semester a specific lecture on dental radiology and diagnosis is held. The first viewing took place at the beginning of the semester (2a), the second at the end of it (2e). The fifth semester (5e) represents students shortly before graduation. While viewing 20 panoramic radiographs showing specific pathologies, the eye m…

Eye Movementsbusiness.industryRadiography610 MedizinEye movement610 Medicine & healthGeneral MedicineDental educationOtorhinolaryngology610 Medical sciencesRadiography PanoramicHumansOptometryMedicineEye trackingRadiology Nuclear Medicine and imagingEye-Tracking Technologybusiness610 Medicine & healthGeneral DentistryPathological
researchProduct

Automatable sample fabrication process for pump-probe X-ray holographic imaging

2014

Soft X-ray holography is a recently developed imaging technique with sub-50 nm spatial resolution. Key advantages of this technique are magnetic and elemental sensitivity, compatibility with imaging at free electron laser facilities, and immunity to in-situ sample excitations and sample drift, which enables the reliable detection of relative changes between two images with a precision of a few nanometers. In X-ray holography, the main part of the experimental setup is integrated in the sample, which consequently requires a large number of fabrication steps. Here we present a generic design and an automatable fabrication process for samples suitable, and optimized for, efficient high resolut…

FabricationMaterials scienceImage qualityDynamic imagingHolographyComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONHolography02 engineering and technologyIterative reconstruction01 natural scienceslaw.inventionOpticslaw0103 physical sciencesDigital image processing010306 general physicsImage resolutionLithographybusiness.industryEquipment Design021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsEquipment Failure AnalysisComputer-Aided DesignRadiographic Image Interpretation Computer-Assisted0210 nano-technologybusinessOptics Express
researchProduct

Imaging Evaluation of Facial Complex Strut Fractures

2012

High-resolution multidetector computed tomography with multiplanar reformations and 3-D postprocessing often provides the detail necessary for preoperative assessment of facial injuries. Maxillofacial fractures are classified in the following manner: upper face fractures, midface fractures (the most frequent), Le Fort fractures, and lower face or mandible fractures. The facial skeleton is a framework of vertical and horizontal buttresses that ensures a better resistance to trauma, but serves also as reference for maxillofacial surgery to restore facial size and shape. Radiologists should know how to diagnose and report the main types of facial fracture.

Facial BoneSkull Fracturesbusiness.industryMandibleDentistryLower faceFacial BonesRadiographic Image Enhancementmedicine.anatomical_structureImaging Three-DimensionalMultidetector computed tomographymedicineHumansFacial skeletonRadiology Nuclear Medicine and imagingbusinessHuman
researchProduct

MHT-X: Offline Multiple Hypothesis Tracking with Algorithm X

2021

An efficient and versatile implementation of offline multiple hypothesis tracking with Algorithm X for optimal association search was developed using Python. The code is intended for scientific applications that do not require online processing. Directed graph framework is used and multiple scans with progressively increasing time window width are used for edge construction for maximum likelihood trajectories. The current version of the code was developed for applications in multiphase hydrodynamics, e.g. bubble and particle tracking, and is capable of resolving object motion, merges and splits. Feasible object associations and trajectory graph edge likelihoods are determined using weak mas…

Fluid Flow and Transfer ProcessesFOS: Computer and information sciencesbubble dynamicsComputer Vision and Pattern Recognition (cs.CV)neutron imagingComputational MechanicsComputer Science - Computer Vision and Pattern RecognitionFluid Dynamics (physics.flu-dyn)General Physics and AstronomyFOS: Physical sciencesPhysics - Fluid DynamicsAlgorithm Ximage processingtwo-phase flowMechanics of Materialsliquid metalX-ray radiography
researchProduct

Tissue Sparing Posterior Cervical Indirect Decompression and Fusion in Foraminal Stenosis

2016

Treatment for patients with cervical foraminal stenosis that present with cervical radiculopathy has experienced rapid progress. Cervical spine surgical options have improved through advances in imaging, instrumentation, implant innovations and novel surgical techniques. While historical treatments are largely safe, comorbidities associated with procedures such as ACDF, TDR, and posterior foraminotomy beg the question if these procedures are too much surgery for select patients that could benefit from a tissue sparing approach. This chapter will introduce a novel, less disruptive surgical technique for achieving indirect decompression and fusion utilizing an intervertebral cervical implant.…

Foraminal stenosismedicine.medical_specialtyNerve rootbusiness.industrymedicine.medical_treatmentRadiographyIndirect decompressionFacet jointSurgerymedicine.anatomical_structureForaminotomymedicineRadiologyImplantTissue sparingbusiness
researchProduct

Characterization of clamp-on current transformers under nonsinusoidal conditions

2009

This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…

Frequency responseMaterials scienceElectric current measurementTransductorAcousticsErrorsTransducersPhase (waves)Energy Engineering and Power TechnologyClamp-on current transformers current transformers (CTs) frequency response power system harmonics transducers.Power transformersDistributed power generationElectric power systemsHarmonic analysisElectric power transmission networksClamp-on current transformersCurrent transformersFrequency responsePower electronicsFrequency measurementElectronic engineeringElectrical and Electronic EngineeringElectrical conductorTomographyComputed tomographyElectric power distributionElectric transformersCircuit faultsFault currentsFundamental frequencyComputerized tomographyFourier seriesCurrent measurementCurrent transformerDiagnostic radiographyElectric instrument transformersElectric frequency measurementPower system harmonicsMedical imagingCurrent transformers (CTs)Air gap (plumbing)Power transmissionElectric network analysisExcitation
researchProduct

Prevalence of Apical Periodontitis in patients with Multiple Myeloma

2020

Background Aim Previous reports have been analyzed the prevalence/association of apical periodontitis (AP) with systemic diseases. The present study aims to analyze the prevalence of healthy/diseased periapex and endodontic treatments in patients with Multiple Myeloma (MM) and compare the results with those of control subjects. Material and Methods Methodology Panoramic radiographs of 50 individuals with MM were evaluated and compared with 50 controls that were sex and age matched exactly with the diseased group. Radiographic analysis was performed by 2 two experienced endodontists under standardized conditions. The periapical status (presence or not of AP) was assessed using the periapical…

Future studiesRadiographyDentistry03 medical and health sciences0302 clinical medicineRadiography PanoramicPrevalencemedicineHumansIn patientGeneral DentistryMultiple myelomaPeriodontitisPeriapical periodontitisbusiness.industryResearchSignificant difference030206 dentistryMedically compromised patients in Dentistrymedicine.diseaseControl subjects:CIENCIAS MÉDICAS [UNESCO]Root Canal TherapyOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryMultiple MyelomabusinessPeriapical Periodontitis
researchProduct

A report of an international collaborative experiment to demonstrate the uniformity obtainable using DNA profiling techniques

1992

This paper describes a collaborative exercise intended to demonstrate whether uniformity of DNA profile results could be achieved between different European laboratories. It was shown that this goal can be obtained provided that a common protocol is followed (specifically the use of a common electrophoretic buffer as being the most important parameter). Generally, lower molecular weight loci (with lower molecular weight fragments) such as YNH24 perform better than higher molecular weight loci such as MS43a. The results of the exercise are discussed in relation to the objectives of the European DNA profiling group (EDNAP).

GeneticsProtocol (science)Quality ControlElectrophoresis Agar GelDNA/bloodRestriction MappingComputational biologyDNABiologySettore MED/43 - MEDICINA LEGALEDNA FingerprintingPathology and Forensic MedicineDNA profilingMulticenter studyAutoradiographyHumansRestriction fragment length polymorphismLaboratoriesLawDNA Fingerprinting/standards
researchProduct

The efficiency of lead thyroid shield in trauma surgery

1997

Die Strahlenbelastung der Operateure bei unfallchirurgischen Eingriffen hat in den letzten Jahren durch den Trend zu biologischen Osteosyntheseverfahren, insbesondere der Marknagelung, zugenommen, da geschlossene Reposition und distale Verriegelung radiologisch kontrolliert werden. Wir wollten jetzt uberprufen, welchen Einflus der Schilddrusenbleischutz auf die Strahlenbelastung der Operateure bei operativen Eingriffen an den unteren Extremitaten hat. Mit Hilfe eines Unterschenkelphantoms wurden unterschiedliche intraoperative Durchleuchtungssituationen simuliert und die Strahlenbelastung der Schilddruse mit und ohne Bleischutz des Operateurs uber ein Dosismesgerat (Szintomat) festgestellt.…

Gynecologymedicine.medical_specialtybusiness.industryFracture fixationmedicineSurgerybusinessRadiographic image interpretationUnfallchirurgie
researchProduct

Progressive calcifications of lung and liver in neonatal herpes simplex virus infection

1991

We report a female neonate who developed severe septicemia presenting with pneumonia and hepatitis due to an infection with herpes simplex virus type II. In spite of antiviral as well as intensive care therapy, three weeks after admission, extensive hepatic calcification was demonstrable on abdominal radiograph, a sign of severe cellular necrosis. In contrast the pulmonary infiltration recovered completely. The clinical follow up was completed by ultrasound and radiography. The infant died at the age of two months secondary to severe postnecrotic hepatic failure. At autopsy, histological evaluation confirmed the former diagnostic and technical findings; in addition, pulmonary calcifications…

HepatitisPathologymedicine.medical_specialtyLungmedicine.diagnostic_testbusiness.industryAutopsymedicine.diseasePneumoniamedicine.anatomical_structureIntensive carePediatrics Perinatology and Child HealthmedicineRadiology Nuclear Medicine and imagingChest radiographbusinessHepatic calcificationCalcificationPediatric Radiology
researchProduct