Search results for "ReCo"
showing 10 items of 8893 documents
Computational volumetric reconstruction of integral imaging with improved depth resolution considering continuously non-uniform shifting pixels
2018
Abstract In this paper, we propose a new computational volumetric reconstruction technique of three-dimensional (3D) integral imaging for depth resolution enhancement by using non-uniform and integer-valued shifting pixels. In a typical integral imaging system, 3D images can be recorded and visualized using a lenslet array. In previous studies, many computational reconstruction techniques such as computational volumetric reconstruction and pixel of elemental images rearrangement technique (PERT) have been reported. However, a computational volumetric reconstruction technique has low visual quality and depth resolution because low-resolution elemental images and uniformly distributed shiftin…
How Gettering Affects the Temperature Sensitivity of the Implied Open Circuit Voltage of Multicrystalline Silicon Wafers
2019
The temperature sensitivity of the open circuit voltage of a solar cell is mainly driven by changes in the intrinsic carrier concentration, but also by the temperature dependence of the limiting recombination mechanisms in the cell. This paper investigates the influence of recombination through metallic impurities on the temperature sensitivity of multicrystalline silicon wafers. Spatially resolved temperature dependent analysis is performed to evaluate the temperature sensitivity of wafers from different brick positions before and after being subjected to phosphorus diffusion gettering. Local spatial analysis is performed on intra-grain areas, dislocation clusters and grain boundaries. Lar…
Evaluation and Comparison of Novel Precursors for Atomic Layer Deposition of Nb2O5 Thin Films
2012
Atomic layer deposition (ALD) of Nb2O5 thin films was studied using three novel precursors, namely, tBuN═Nb(NEt2)3, tBuN═Nb(NMeEt)3, and tamylN═Nb(OtBu)3. These precursors are liquid at room temperature, present good volatility, and are reactive toward both water and ozone as the oxygen sources. The deposition temperature was varied from 150 to 375 °C. ALD-type saturative growth modes were confirmed at 275 °C for tBuN═Nb(NEt2)3 and tBuN═Nb(NMeEt)3 together with both oxygen sources. Constant growth rate was observed between a temperature regions of 150 and 325 °C. By contrast, amylN═Nb(OtBu)3 exhibited limited thermal stability and thus a saturative growth mode was not achieved. All films we…
Atomic Layer Deposition of LiF Thin Films from Lithd, Mg(thd)2, and TiF4 Precursors
2013
Lithium fluoride is an interesting material because of its low refractive index and large band gap. Previously LiF thin films have been deposited mostly by physical methods. In this study a new way of depositing thin films of LiF using atomic layer deposition (ALD) is presented. Mg(thd)2, TiF4 and Lithd were used as precursors, and they produced crystalline LiF at a temperature range of 300–350 °C. The films were studied by UV–vis spectrometry, field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), atomic force microscopy (AFM), time-of-flight elastic recoil detection analysis (ToF-ERDA), and energy dispersive X-ray spectroscopy (EDX). In addition, film adhesion was t…
Conceptual study of a heavy-ion-ERDA spectrometer for energies below 6 MeV
2017
Abstract Elastic recoil detection analysis (ERDA) is a well established technique and it offers unique capabilities in thin film analysis. Simultaneous detection and depth profiling of all elements, including hydrogen, is possible only with time-of-flight ERDA. Bragg ionization chambers or Δ E - E detectors can also be used to identify the recoiling element if sufficiently high energies are used. The chief limitations of time-of-flight ERDA are the beam induced sample damage and the requirement of a relatively large accelerator. In this paper we propose a detector setup, which could be used with 3 MeV to 6 MeV medium heavy beams from either a single ended accelerator (40Ar) or from a tandem…
Analysis of thin high-k and silicide films by means of heavy ion time-of-flight forward-scattering spectrometry
2006
The use of forward scattered heavy incident ions in combination with a time-of-flight-energy telescope provides a powerful tool for the analysis of very thin (5–30 nm) films. This is because of greater stopping powers and better detector energy resolution for heavier ions than in conventional He-RBS. Because of the forward scattering angle, the sensitivity is greatly enhanced, thus reducing the ion beam induced desorption during the analysis of very thin films. The drawback of forward scattering angle is the limited mass separation for target elements. We demonstrate the performance of the technique with the analysis of 25 nm thick NiSi films and atomic layer deposited 6 nm thick HfxSiyOz f…
Mass calibration of the energy axis in ToF- E elastic recoil detection analysis
2016
We report on procedures that we have developed to mass-calibrate the energy axis of ToF-E histograms in elastic recoil detection analysis. The obtained calibration parameters allow one to transform the ToF-E histogram into a calibrated ToF-M histogram.
Simulations on time-of-flight ERDA spectrometer performance
2016
The performance of a time-of-flight spectrometer consisting of two timing detectors and an ionization chamber energy detector has been studied using Monte Carlo simulations for the recoil creation and ion transport in the sample and detectors. The ionization chamber pulses have been calculated using Shockley-Ramo theorem and the pulse processing of a digitizing data acquisition setup has been modeled. Complete time-of-flight–energy histograms were simulated under realistic experimental conditions. The simulations were used to study instrumentation related effects in coincidence timing and position sensitivity, such as background in time-of-flight–energy histograms. Corresponding measurement…
Data-driven Fault Diagnosis of Induction Motors Using a Stacked Autoencoder Network
2019
Current signatures from an induction motor are normally used to detect anomalies in the condition of the motor based on signal processing techniques. However, false alarms might occur if using signal processing analysis alone since missing frequencies associated with faults in spectral analyses does not guarantee that a motor is fully healthy. To enhance fault diagnosis performance, this paper proposes a machinelearning based method using in-built motor currents to detect common faults in induction motors, namely inter-turn stator winding-, bearing- and broken rotor bar faults. This approach utilizes single-phase current data, being pre-processed using Welch’s method for spectral density es…
Low complexity digital background calibration algorithm for the correction of timing mismatch in time-interleaved ADCs
2019
Abstract A low-complexity post-processing algorithm to estimate and compensate for timing skew error in a four-channel time-interleaved analog to digital converter (TIADC) is presented in this paper, together with its hardware implementation. The Lagrange interpolator is used as the reconstruction filter which alleviates online interpolator redesign by using a simplified representation of coefficients. Simulation results show that the proposed algorithm can suppress error tones for input signal frequency from 0 to 0.4 f s . The proposed structure has, at least, 41% reduction in the number of required multipliers. Implementation of the algorithm, for a four-channel 10-bit TIADC, show that, f…