Fishing for a drug: solid-phase microextraction for the assay of clozapine in human plasma
1999
Solid-phase microextraction (SPME) was investigated as a sample preparation method for assaying the neuroleptic drug clozapine in human plasma. A mixture of human plasma, water, loxapine (as internal standard) and aqueous NaOH was extracted with a 100-micron polydimethylsiloxane (PDMS) fiber (Supelco). Desorption of the fiber was performed in the injection port of a gas chromatograph at 260 degrees C (HP 5890; 30 m x 0.53 mm I.D., 1 micron film capillary; nitrogen-phosphorous selective detection). Fibers were used repeatedly in up to about 75 analyses. The recovery was found to be 3% for clozapine from plasma after 30 min of extraction. However, in spite of the low recovery, the analyte was…
Automatic in-tube SPME and fast liquid chromatography: A cost-effective method for the estimation of dibuthyl and di-2-ethylhexyl phthalates in envir…
2007
A 80-cm length commercially available capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane (TBR-5) was employed to carry out on-line extraction and preconcentration of dibuthyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) in the chromatographic system. The coated capillary was placed between the sample injection loop and the injection needle of an autosampler. Variables affecting the automatic in-tube solid-phase microextraction (SPME) were optimized. A Genesis C(18) (5 cm x 4.6 mm i.d., 4 microm particle size) was employed as analytical column. The achieved limits of detection by use of diode array detection were 1 and 2.5 microg L(-1), respectively. The propo…
Analysis of post-harvest fungicides by micellar electrokinetic chromatography.
2001
A method based on solid-phase extraction (SPE) and micellar electrokinetic chromatography (MEKC) was developed for the simultaneous determination of carbendazim, imazalil, methylthiophanate, O-phenylphenol, prochloraz, procimidone, thiabendazole and triadimefon residues in grape, lettuce, orange and tomato. Selectivity and resolution were studied changing the pH and the concentration of the buffer, the type and concentration of surfactant and the methanol content in the mobile phase. A buffer consisting of 4 mM borate with 75 mM sodium cholate (pH 9.2) gave the best results. The recoveries of the fungicides in spiked fruit and vegetable samples ranged from 30 to 105%, and the limits of dete…
Determination of uranium in tap water by ICP-MS
2000
A fast and accurate procedure has been developed for the determination of uranium at microg L(-1) level in tap and mineral water. The method is based on the direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma mass spectrometer (ICP-MS). Uranium was determined at the mass number 238 using Rh as internal standard. The method provides a limit of detection of 2 ng L(-1) and a good repeatability with relative standard deviation values (RSD) about 3% for five independent analyses of samples containing 73 microg L(-1) of uranium. Recovery percentage values found for the determination of uranium in spiked natural samples varied between 91% and 106%…
A microanalytical method for ammonium and short-chain primary aliphatic amines using precolumn derivatization and capillary liquid chromatography.
2007
Abstract A new microscale method is presented for the determination of ammonium and primary short-chain aliphatic amines (methylamine, ethylamine, propylamine, n -butylamine and n -pentylamine) in water. The assay uses precolumn derivatization with the reagent o -phthaldialdehyde (OPA) in combination with the thiol N -acetyl- l -cysteine (NAC), and capillary liquid chromatography with UV detection at 330 nm. The described method is very simple and rapid as no preconcentration of the analytes is necessary, and the volume of sample required is only 0.1 mL. Under the proposed conditions good linearity has been obtained up to a concentration of the analytes of 10.0 mg L −1 , the limits of detec…
A solid-phase extraction and size-exclusion liquid chromatographic method for polyethylene glycol 25 p-aminobenzoic acid determination in urine: Vali…
2007
No previous publications about percutaneous absorption of polyethylene glycol 25 p-aminobenzoic acid (PEG-25 PABA) have been found in the literature and the expected levels to be found in human urine after sunscreens use are unknown. The method proposed here is suitable to determine PEG-25 PABA in the urine of sunscreens users in order to carry out studies on body accumulation/excretion. It is based on solid-phase extraction (SPE) with size-exclusion liquid chromatography determination. Solid-phase extraction allows the analyte to be retained and subsequently eluted for a clean-up, using a silica-based cartridge. The size-exclusion liquid chromatography of the eluted allows the rest of matr…
Simultaneous determination of olanzapine, clozapine and demethylated metabolites in serum by on-line column-switching high-performance liquid chromat…
2001
An automated method for simultaneous routine quantification of the antipsychotic drugs clozapine, olanzapine and their demethylated metabolites is described. The method included adsorption on a cyanopropyl (CPS) coated clean-up column (10 microm; 10 x 2.0 mm I.D.), washing off interfering serum constituents to waste, and separation on C18 ODS Hypersil reversed phase material (5 microm; 250 x 4.6 mm I.D.) using acetonitrile-water-tetramethylethylenediamine (37:62.6:0.4, v/v/v) adjusted to pH 6.5 with concentrated acetic acid. UV-detection was performed at 254 nm. The limit of quantification was 10-20 ng/ml. Relative day to day standard variations ranged between 4.5 and 13.5%. The method is s…
High-performance liquid chromatographic determination of tocopherols in infant formulas
2002
A method for the simultaneous determination of alpha-tocopherol acetate and alpha-, delta-, and gamma-tocopherols by normal-phase high-performance liquid chromatography (HPLC) with a fluorescent detector in infant formula is proposed. The values obtained in the determination of the analytical parameters: linearity, precision, limit of detection and accuracy (analysis of a standard reference material, SRM 1846), confirm the quality of the method. The proposed method is useful for the determination of alpha-, delta-, and gamma-tocopherols and alpha-tocopherol acetate in infant formulas at a low cost and in a total time of 2 h.
Application of ACC method to synchronous luminiscence: determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages.
2001
A new method based on the Q parameter, that permits the determination of the C(compound A)/C(compound B) ratio without preparing calibration graphs of the two compounds, is proposed. This method has been applied to signals obtained by synchronous luminiscence. Simultaneous determination of alpha-tocopherol and alpha-tocopheryl acetate in beverages using synchronous fluorescence has been carried out. To isolate the compounds from samples, liquid extraction with n-hexane as the organic phase was employed. The presence of interferences was tested using the apparent content curves (ACC) method and the C(alpha-tocopherol)/C(alpha-tocopheryl acetate) ratio was calculated using the Q parameter. Th…
High-performance liquid chromatography of lactose with evaporative light scattering detection, applied to determine fine particle dose of carrier in …
2005
A method for quantification of the fine particle dose of lactose is described, using a hydrophilic interaction chromatography (HILIC) method and evaporative light scattering detection. The HILIC method used an aminopropyl column and a mobile phase consisting of acetonitril/water (80/20, v/v) for isocratic elution. Sensitive chromatography was obtained using a low concentration of water in the extraction solvent. The detection limit (RSD10%) at an injection volume of 10 microL is 10 microg/mL. Linearity was obtained in the range of 10-80 microg/mL (R(2)0.99). A relative standard deviation (RSD) of 0.5% (N=6) demonstrated good precision of the optimized method.