Search results for "STANDARD"

showing 10 items of 3299 documents

Comparative Study on the Determination of Cephalexin in its Dosage Forms by Spectrophotometry and HPLC with UV-vis Detection

1997

This paper discusses the spectrophotometric determination of cephalexin as the intact cephalexin or as its acid-induced degradation product. Cephalexin can be determined in the range 1 × 10−5−18 × 10−5M with relative standard deviations of 5-1%. The limits of quantitation and detection were 10−5 and 0.3 × 10−5M, respectively. These procedures were compared with reversed-phase HPLC determination. No interference was observed in the presence of common pharmaceutical adjuvants. The H-point standard additions method was applied in order to correct for the possible presence of the cephalexin precursor, 7-aminocephalosporanic acid; this improves the selectivity of the UV-vis spectrophotometric me…

Chromatographymedicine.diagnostic_testChemistryHigh-performance liquid chromatographyDosage formAnalytical ChemistryUltraviolet visible spectroscopyCefalexinSpectrophotometryStandard additionmedicineQuantitative analysis (chemistry)medicine.drugAntibacterial agent
researchProduct

A comparison of various calibration techniques applied to the ninhydrin-cefoxitin determination

1996

Abstract This report deals with spectrophotometric determination of cefoxitin from intact antibiotics or from its acid induced degradation product by means of their reaction with ninhydrin in a strong sulphuric acid medium. To obtain the calibration graphs four methods were used: absorbance of reacted cefoxitin against a reagent blank as an analytical signal, first-derivative signal of absorbance against a water blank as an analytical signal, first-derivative signal of absorbance against a reagent blank as an analytical signal and the H-Point Standard Additions Method (HPSAM) by using absorbance increment values as analytical signals. The HPSAM is applied to the determination of cefoxitin i…

Chromatographymedicine.diagnostic_testChemistrydigestive oral and skin physiologyBiochemistryBlankHigh-performance liquid chromatographyAnalytical ChemistryAbsorbancechemistry.chemical_compoundSpectrophotometryNinhydrinReagentStandard additionmedicineEnvironmental ChemistryCefoxitinSpectroscopymedicine.drugAnalytica Chimica Acta
researchProduct

Development of the H-point standard additions method for coupled liquid chromatography and UV-visible spectrophotometry

1992

Abstract This work establishes the fundamentals of the H-point standard additions method for liquid chromatography for the simultaneous analysis of binary mixtures with overlapped chromatographic peaks. The method was compared with the deconvolution method of peak suppression and the second derivative of elution profiles. Different mixtures of diuretics were satisfactorily resolved.

Chromatographymedicine.diagnostic_testElutionChemistryAnalytical chemistryBiochemistryAnalytical ChemistrySpectrophotometryStandard additionmedicineEnvironmental ChemistryDeconvolutionSpectroscopySecond derivativeAnalytica Chimica Acta
researchProduct

Comparison of spectrophotometric and HPLC methods for determining sialic acid in infant formulas

2011

Abstract Two methods for determining sialic acid in infant formulas – spectrophotometry and HPLC with fluorescence detection – have been optimised and validated, the first one allows to determine total sialic acid while the second allows to differentiate the two main forms of sialic acid (N-acetylneuraminic acid (Neu5Ac) and N-glycolylneuraminic acid (Neu5Gc)). A common sample preparation procedure (hydrolysis and purification) for both methods has been proposed. The linearity (from 6 to 150 μg of total sialic acid in the assay for spectrophotometry, and from 12.5 to 250 ng and 1 to 5 ng of Neu5Ac and Neu5Gc, respectively, for HPLC) is adequate. The detection and quantification limits (0.29…

Chromatographymedicine.diagnostic_testRelative standard deviationGeneral MedicineHigh-performance liquid chromatographyFluorescenceAnalytical ChemistrySialic acidHydrolysischemistry.chemical_compoundInfant formulachemistrySpectrophotometrymedicineSample preparationFood ScienceFood Chemistry
researchProduct

Rapid and simultaneous high-performance liquid chromatography assay of polyamines and monoacetylpolyamines in biological specimens

2000

A rapid, resolutive and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for polyamines and acetylpolyamines by adopting pre-column derivatization with benzoyl chloride. In a single run lasting less than 15 min ten polyamines were separated as well as traces of benzoic acid, methylbenzoate and benzoic anhydride. These contaminants, produced during the derivatization reaction, were almost all eliminated by washing steps envisaged in the same procedure. This simple and sensitive method can be applied to routine determination of polyamines in biological samples. A fine application of this procedure to the determination of endogenous content of p…

Chromatographymedicine.diagnostic_testorganic chemicalsBiogenic PolyaminesReproducibility of ResultsGeneral ChemistryReversed-phase chromatographyReference StandardsSensitivity and SpecificityHigh-performance liquid chromatographyBenzoic anhydridechemistry.chemical_compoundBenzoyl chloridechemistrySpectrophotometrymedicineSpectrophotometry UltravioletDerivatizationQuantitative analysis (chemistry)Chromatography High Pressure LiquidBenzoic acidJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

Determination of chromium in treated crayfish,Procambarus clarkii, by Electrothermal AAS: Study of chromium accumulation in different tissues

1986

In the present study, the authors investigated the accumulation of chromium in muscle, hepatopancreas, antennal glands, and gills of Procambarus clarkii (Girard) from Lake Albufera following Cr(VI)-exposure. Determinations of chromium were made by using Electrothermal Atomic Absorption Spectroscopy and the standard additions method.

Chromiuminorganic chemicalsGillChromium CompoundsHealth Toxicology and Mutagenesischemistry.chemical_elementAstacoideaToxicologylaw.inventionChromiumlawAnimalsTissue DistributionProcambarus clarkiibiologySpectrophotometry AtomicGeneral Medicinebiology.organism_classificationCrayfishPollutionKineticschemistryEnvironmental chemistryStandard additionIndicators and ReagentsHepatopancreasAtomic absorption spectroscopyBulletin of Environmental Contamination and Toxicology
researchProduct

HL7v3 CDA Rel.2 Patient Summary and Chronic Care Model: Localization experience and GP/HS Integration Project

2010

The localization experience for the Patient Summary, based on the Health Level Seven Version 3 (HL7v3) Clinical Document Architecture, Release 2 (CDA Rel.2), is presented. An overview of the Chronic Care Model (CCM) is introduced with particular attention to the clinical information systems, in order to organize patient and population clinical data by sharing information among healthcare providers in management of chronic diseases. We propose, as case study, a project for the integration of various services for General Practitioners (GP) and Hospital Specialists (HS), accessing the Electronic Health Record (EHR), implementing the Patient Summary and managing the exchange of Chronic Care med…

Chronic careSettore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionieducation.field_of_studybusiness.industryMedical recordPopulationInteroperabilityCommunities Hospitals Standards developmentContext (language use)computer.file_formatClinical Document Architecturemedicine.diseaseSettore ING-INF/04 - AutomaticaHealth caremedicineNormativeMedical emergencyeducationbusinesscomputer
researchProduct

Performance of jet substructure techniques for large-$R$ jets in proton-proton collisions at $\sqrt{s}$ = 7 TeV using the ATLAS detector

2013

This paper presents the application of a variety of techniques to study jet substructure. The performance of various modified jet algorithms, or jet grooming techniques, for several jet types and event topologies is investigated for jets with transverse momentum larger than 300 GeV. Properties of jets subjected to the mass-drop filtering, trimming, and pruning algorithms are found to have a reduced sensitivity to multiple proton-proton interactions, are more stable at high luminosity and improve the physics potential of searches for heavy boosted objects. Studies of the expected discrimination power of jet mass and jet substructure observables in searches for new physics are also presented.…

Ciencias FísicasPhysics beyond the Standard ModelHadronMonte Carlo method01 natural sciencesHigh Energy Physics - Experiment//purl.org/becyt/ford/1 [https]High Energy Physics - Experiment (hep-ex)Jets[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Invariant massNuclear ExperimentHADRONIC JEThadron-hadron scatteringQCPhysicsLarge Hadron ColliderAtlas (topology)Settore FIS/01 - Fisica SperimentaleObservableATLASPhysical SciencesComputingMethodologies_DOCUMENTANDTEXTPROCESSINGproton–proton collisionLHCCIENCIAS NATURALES Y EXACTASParticle Physics - ExperimentParticle physicsNuclear and High Energy PhysicsCiências Naturais::Ciências Físicas530 PhysicsAstrophysics::High Energy Astrophysical Phenomena:Ciências Físicas [Ciências Naturais]FOS: Physical sciencesddc:500.2530Nuclear physics0103 physical sciencesFysikddc:530High Energy Physics010306 general physicsCiencias ExactasScience & TechnologyHadron-Hadron ScatteringATLAS detector010308 nuclear & particles physicsFísica//purl.org/becyt/ford/1.3 [https]AstronomíaHADRON-HADRON COLLISIONSExperimental High Energy PhysicsSubstructureHigh Energy Physics::Experiment
researchProduct

Liquid chromatography/atmospheric pressure chemical ionization-mass spectrometric analysis of benzoylurea insecticides in citrus fruits.

2000

A liquid chromatography (LC) method for the quantitative determination of three benzoylurea insecticide residues (diflubenzuron, flufenoxuron and hexaflumuron) in citrus fruits is described. Residues were successfully separated on a C18 column by methanol/water gradient elution. Detection was by negative-ion, selected-ion monitoring atmospheric pressure chemical ionization-mass spectrometry (APCI-MS); the main ions were [M - H]-, and the secondary fragment ions were [M - H - HF]-. Useful confirmatory information can thus be obtained at low extraction voltages from losses of HF. Detection limits for standard solutions were 10 fg injected and good linearity and reproducibility were obtained. …

CitrusInsecticidesBenzoylureaAnalytical chemistryAtmospheric-pressure chemical ionizationStandard solutionMass spectrometrySensitivity and SpecificityMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundmedicineSpectroscopyDichloromethaneDetection limitChromatographyAtmospheric pressureElutionPhenylurea CompoundsOrganic ChemistryPesticide ResidueschemistryBenzamidesDiflubenzuronmedicine.drugChromatography LiquidRapid communications in mass spectrometry : RCM
researchProduct

The PASSI and Agile PASSI MAS Meta-models Compared with a Unifying Proposal

2005

A great number of processes for multi-agent systems design have been presented in last years to support the different approaches to agent-oriented design; each process is specific for a particular class of problems and it instantiates a specific MAS meta-model. These differences produce inconsistences and overlaps: a MAS meta-model may define a term not referred by another, or the same term can be used with a different meaning. We think that the lack of a standardization may cause a significant delay to the diffusion of the agent paradigm outside research context. Working for this unification goal, it is also necessary to define in unambiguous way the terms of the agent model and their rela…

Class (computer programming)Use Case DiagramStandardizationbusiness.industryProcess (engineering)Computer scienceComputer Science (all)ComputingMethodologies_ARTIFICIALINTELLIGENCETheoretical Computer ScienceMetamodelingDesign processSystems designArtificial intelligencebusinessSoftware engineeringAdaptation (computer science)Agile software development
researchProduct