Search results for "STED"

showing 10 items of 2256 documents

New Cost Effective Titanium Based Protective and Decorative Coatings by Ion Plating Plasma Assisted IPPA

2009

The activity aiming to replace galvanic treatments by vacuum processes is based on the effort to reduce the production costs and to set-up new decorative effects impossible to be galvanically realised because the use of dielectric materials. This work describes cost effective metal-oxide and oxide-metal-oxide decorative coatings based on the use of titanium as basic material deposited by Ion Plating Plasma Assisted from Reactive Magnetron Sputtering source. A new multilayer protective and decorative structure, based on the use of titanium and titanium oxides is also presented. The protective effect against aggressive environment is obtained by alternating layers of metal and metal-oxide mix…

IPPAIon Plating Plasma AssistedSettore ING-INF/02 - Campi ElettromagneticiThin film depositionProtective and Decorative Coating
researchProduct

Assisted Reproductive Techniques and Risk of Congenital Heart Diseases in Children: a Systematic Review and Meta-analysis

2023

AbstractInfertility is a growing phenomenon and leads to an increased use of assisted reproductive techniques (ARTs). In recent years, concerns about the safety of these procedures emerged and ARTs were hypothesized to be a risk factor for developing congenital heart diseases (CHDs) in offspring. Our aim is to investigate the association between ART and CHD, specifying results according to various subtypes of defects. We performed a systematic review and random-effects meta-analysis following the PRISMA guidelines. MEDLINE and Google Scholar were searched from January 2011 to May 2022. Data about incidence of CHD in ART were tabulated and extracted from all the studies included. Twenty-four…

IVFIn vitro fertilizationAssisted reproductive techniqueObstetrics and GynecologySettore MED/40 - Ginecologia E OstetriciaCardiac defectCongenital heart diseaseReproductive Sciences
researchProduct

Listeria monocytogenes EGD-e biofilms: no mushrooms but a network of knitted chains.

2008

ABSTRACT Listeria monocytogenes is a food pathogen that can attach on most of the surfaces encountered in the food industry. Biofilms are three-dimensional microbial structures that facilitate the persistence of pathogens on surfaces, their resistance toward antimicrobials, and the final contamination of processed goods. So far, little is known about the structural dynamics of L. monocytogenes biofilm formation and its regulation. The aims of this study were, by combining genetics and time-lapse laser-scanning confocal microscopy (LSCM), (i) to characterize the structural dynamics of L. monocytogenes EGD-e sessile growth in two nutritional environments (with or without a nutrient flow), and…

Image ProcessingMESH : Analysis of Variance[ SDV.MP.BAC ] Life Sciences [q-bio]/Microbiology and Parasitology/BacteriologyMESH : Green Fluorescent Proteinsmedicine.disease_causeMESH: Listeria monocytogenesApplied Microbiology and BiotechnologyBacterial Adhesionlaw.inventionGreen fluorescent proteinPlasmidComputer-AssistedlawGenes ReporterImage Processing Computer-AssistedMESH : Bacterial ProteinsMESH: Microscopy ConfocalPathogenMESH: Bacterial Proteins2. Zero hunger0303 health sciencesMicroscopyMicroscopy ConfocalPhotobleachingEcologybiologyMESH: KineticsMESH : Genes ReporterMESH: Image Processing Computer-AssistedMESH : BiofilmsConfocalMESH : KineticsMESH: PhotobleachingMESH : Image Processing Computer-AssistedBiotechnologyPlasmidsMESH : Bacterial AdhesionConfocalGreen Fluorescent ProteinsMESH: BiofilmsMESH : PhotobleachingMicrobiology03 medical and health sciencesMESH: Gene Expression ProfilingMESH: Green Fluorescent ProteinsListeria monocytogenesBacterial ProteinsConfocal microscopyMESH: PlasmidsMESH: Analysis of VariancemedicineMESH: Bacterial AdhesionMESH : Microscopy ConfocalReporter030304 developmental biologyAnalysis of Variance030306 microbiologyMESH : Gene Expression ProfilingGene Expression ProfilingMESH: Genes ReporterBiofilmbiochemical phenomena metabolism and nutritionbiology.organism_classification[SDV.MP.BAC]Life Sciences [q-bio]/Microbiology and Parasitology/BacteriologyListeria monocytogenesCulture MediaKineticsGenesMESH : PlasmidsBiofilmsMESH: Culture MediaFood MicrobiologyMESH : Culture MediaMESH : Listeria monocytogenesBacteriaFood ScienceApplied and environmental microbiology
researchProduct

Dual-beam confocal light-sheet microscopy via flexible acousto-optic deflector

2019

Confocal detection in digital scanned laser light-sheet fluorescence microscopy (DSLM) has been established as a gold standard method to improve image quality. The selective line detection of a complementary metal-oxide-semiconductor camera (CMOS) working in rolling shutter mode allows the rejection of out-of-focus and scattered light, thus reducing background signal during image formation. Most modern CMOS have two rolling shutters, but usually only a single illuminating beam is used, halving the maximum obtainable frame rate. We report on the capability to recover the full image acquisition rate via dual confocal DSLM by using an acoustooptic deflector. Such a simple solution enables us t…

Image formationPaperMaterials scienceImage qualityConfocalBiomedical Engineeringacousto-optic deflector; confocal detection; digital scanned laser light-sheet fluorescence microscopy; high contrast; high-throughput microscopy; light-sheet microscopy; mouse brain; zebrafish brainconfocal detection01 natural scienceslaw.invention010309 opticsBiomaterialsMiceacousto-optic deflectorOpticslaw0103 physical sciencesMicroscopyImage Processing Computer-AssistedAnimalsZebrafishhigh-throughput microscopyconfocal light-sheet microscopyMicroscopyMicroscopy Confocalbusiness.industryhigh contrastRolling shutterBrainEquipment DesignLaserFrame ratezebrafish brainAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsHigh-Throughput Screening AssaysMice Inbred C57BLdigital scanned laser light-sheet fluorescence microscopyMicroscopy FluorescenceLight sheet fluorescence microscopyLarvamouse brainbusinesslight-sheet microscopyJournal of Biomedical Optics
researchProduct

Software for automated application of a reference-based method fora posterioridetermination of the effective radiographic imaging geometry

2005

Objectives: Presentation and validation of software developed for automated and accurate application of a reference-based algorithm (reference sphere method: RSM) inferring the effective imaging geometry from quantitative radiographic image analysis. Methods: The software uses modern pattern recognition and computer vision algorithms adapted for the particular application of automated detection of the reference sphere shadows (ellipses) with subpixel accuracy. It applies the RSM algorithm to the shadows detected, thereby providing threedimensional Cartesian coordinates of the spheres. If the three sphere centres do not lie on one line, they uniquely determine the imaging geometry. Accuracy …

Image formationSoftware ValidationImage registrationGeometryMandibleEllipsePattern Recognition Automatedlaw.inventionImaging Three-DimensionalSoftwareArtificial IntelligenceSoftware DesignlawImage Processing Computer-AssistedHumansSuperimpositionRadiology Nuclear Medicine and imagingCartesian coordinate systemGeneral DentistryMathematicsbusiness.industryRadiography Dental DigitalGeneral MedicineSubpixel renderingOtorhinolaryngologyCalibrationLine (geometry)businessAlgorithmsSoftwareDentomaxillofacial Radiology
researchProduct

The impact of irreversible image data compression on post-processing algorithms in computed tomography

2020

PURPOSE: We aimed to evaluate the influence of irreversible image compression at varying levels on image post-processing algorithms (3D volume rendering of angiographs, computer-assisted detection of lung nodules, segmentation and volumetry of liver lesions, and automated evaluation of functional cardiac imaging) in computed tomography (CT). METHODS: Uncompressed CT image data (30 angiographs of the lower limbs, 38 lung exams, 20 liver exams and 30 cardiac exams) were anonymized and subsequently compressed using the JPEG2000 algorithm with compression ratios of 8:1, 10:1, and 15:1. Volume renderings of CT angiographies obtained from compressed and uncompressed data were compared using objec…

Image processing030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineGeneral RadiologyImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingLungCardiac imagingRetrospective Studiesbusiness.industryReproducibility of ResultsExtremitiesHeartVolume renderingData CompressionUncompressed videoLiverTomographyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAlgorithmVolume (compression)Image compressionData compressionDiagnostic and Interventional Radiology
researchProduct

Multifacet structure of observed reconstructed integral images.

2005

Three-dimensional images generated by an integral imaging system suffer from degradations in the form of grid of multiple facets. This multifacet structure breaks the continuity of the observed image and therefore reduces its visual quality. We perform an analysis of this effect and present the guidelines in the design of lenslet imaging parameters for optimization of viewing conditions with respect to the multifacet degradation. We consider the optimization of the system in terms of field of view, observer position and pupil function, lenslet parameters, and type of reconstruction. Numerical tests are presented to verify the theoretical analysis.

Image qualityComputer scienceInformation Storage and RetrievalField of viewIterative reconstructionLensletModels BiologicalSensitivity and SpecificityUser-Computer InterfaceOpticsImaging Three-DimensionalArtificial IntelligencePupil functionImage Interpretation Computer-AssistedComputer GraphicsHumansComputer SimulationIntegral imagingModels Statisticalbusiness.industryReproducibility of ResultsObserver (special relativity)GridImage EnhancementAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisual PerceptionComputer Vision and Pattern RecognitionbusinessAlgorithmsJournal of the Optical Society of America. A, Optics, image science, and vision
researchProduct

Emission tomography with a large-hole collimator (CACAO): a possible new way to improve radionuclide imaging.

2002

This work aims to improve the quality of scintigraphy. It evaluates the use of a large-hole collimator, the Computer Aided Collimation Gamma Camera Project (CACAO), in SPECT. Acquisition data from the same object were simulated for CACAO and for a conventional collimator. Better signal-to-noise ratios were found for CACAO images, whatever the number of emitted photons. This work demonstrates that high-resolution images may be obtained with large-hole collimators. The combination of CACAO and pixilated detectors may further improve radionuclide imaging.

Image qualityImage processingIterative reconstructionCollimated light030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineOpticslawImage Processing Computer-AssistedMedicineHumansRadiology Nuclear Medicine and imaging[SDV.NEU] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Radionuclide ImagingComputingMilieux_MISCELLANEOUSGamma camera[SDV.IB] Life Sciences [q-bio]/BioengineeringPhotonsbusiness.industryDetectorCollimator030220 oncology & carcinogenesisCalibration[SDV.IB]Life Sciences [q-bio]/Bioengineering[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]TomographybusinessNuclear medicineAlgorithmsJournal of computer assisted tomography
researchProduct

Diffusion equations with negentropy applied to denoise mammographic images.

2006

Mammography is a radiographic technique used for the detection of breast lesions. The analysis of the digital image normally requires a previous application of filters as a preprocessing step to reduce the noise level of the image, while preserving important details to carry out a suitable diagnostic. In the literature, there are a large amount of denoising techniques applied to different medical images. In this work we have studied the performance of a diffusive filter with a stopping condition based on the statistical concept of negentropy, applied to denoise mammographic images. The negentropy has been succesfully prove with other denoising methods as independent component analysis by th…

Image qualityNoise reductionEntropyPhysics::Medical PhysicsNormal DistributionBreast NeoplasmsDiffusionDigital imagesymbols.namesakeBreast DiseasesHumansComputer visionImage restorationMathematicsModels Statisticalbusiness.industryWiener filterReproducibility of ResultsFilter (signal processing)Models TheoreticalNon-local meansRadiographic Image EnhancementComputer Science::Computer Vision and Pattern RecognitionSubtraction TechniquesymbolsRadiographic Image Interpretation Computer-AssistedNegentropyArtificial intelligencebusinessArtifactsAlgorithmsMammography
researchProduct

Evaluation of Erythema Severity in Dermatoscopic Images of Canine Skin: Erythema Index Assessment and Image Sampling Reliability.

2021

The regular monitoring of erythema, one of the most important skin lesions in atopic (allergic) dogs, is essential for successful anti-allergic therapy. The smartphone-based dermatoscopy enables a convenient way to acquire quality images of erythematous skin. However, the image sampling to evaluate erythema severity is still done manually, introducing result variability. In this study, we investigated the correlation between the most popular erythema indices (EIs) and dermatologists’ erythema perception, and we measured intra- and inter-rater variability of the currently-used manual image-sampling methods (ISMs). We showed that the EIBRG, based on all three RGB (red, green, and blue) channe…

Image samplingSkin erythemamedicine.medical_specialtyErythema040301 veterinary sciencesIntraclass correlationsmartphone dermatoscopyintraclass correlation coefficientlcsh:Chemical technologyBiochemistrySpearman's rank correlation coefficientSeverity of Illness IndexAnalytical ChemistrySpecimen Handling0403 veterinary science030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineDogsImage Interpretation Computer-Assistedmultispectral imagingMedicineerythema indexAnimalslcsh:TP1-1185Dog DiseasesElectrical and Electronic EngineeringInstrumentationReliability (statistics)SkinDermatoscopymedicine.diagnostic_testintegumentary systembusiness.industryCommunicationReproducibility of Results04 agricultural and veterinary sciencesCADESI4DermatologyAtomic and Molecular Physics and Optics3. Good healthErythemacanine atopic dermatitiserythema severityimage samplingmedicine.symptombusinessSkin lesiondisease severity scalesSensors (Basel, Switzerland)
researchProduct