Search results for "STED"
showing 10 items of 2256 documents
Quantitative and integrative proteome analysis of peripheral nerve myelin identifies novel myelin proteins and candidate neuropathy loci
2011
Peripheral nerve myelin facilitates rapid impulse conduction and normal motor and sensory functions. Many aspects of myelin biogenesis, glia–axonal interactions, and nerve homeostasis are poorly understood at the molecular level. We therefore hypothesized that only a fraction of all relevant myelin proteins has been identified so far. Combining gel-based and gel-free proteomic approaches, we identified 545 proteins in purified mouse sciatic nerve myelin, including 36 previously known myelin constituents. By mass spectrometric quantification, the predominant P0, periaxin, and myelin basic protein constitute 21, 16, and 8% of the total myelin protein, respectively, suggesting that their relat…
Identification of antigenic proteins from Echinostoma caproni (Trematoda) recognized by mouse immunoglobulins M, A and G using an immunoproteomic app…
2008
Antigenic proteins of Echinostoma caproni (Trematoda) against mouse IgM, IgA, IgG, IgG1 and IgG2a were investigated by immunoproteomics. Excretory/secretory products (ESP) of E. caproni separated by two-dimensional (2D) gel electrophoresis were transferred to nitrocellulose membranes and probed with the different mouse immunoglobulin classes. A total of four proteins (enolase, 70 kDa heat-shock protein (HSP-70), actin and aldolase) were accurately identified. Enolase was recognized in eight different spots of which seven of them were detected in the expected molecular weight and were recognized by IgA, IgG or IgG and IgG1. Another spot identified as enolase at 72 kDa was only recognized by …
Vessel painting of the microcirculation using fluorescent lipophilic tracers
2005
Flexible approaches to defining microvessel morphometry are useful in the study of both acute and chronic structural changes of the microcirculation. In this report, we examined the utility of the intravascular infusion of lipophilic carbocyanine tracers in the structural assessment of the retina, skin, lung, and colon microcirculation. The microvessel labeling technique, here termed fluorescent vessel painting, involved the intravascular injection of sulfonated lipophilic carbocyanine tracers. The utility of vessel painting in morphometry was assessed using morphometric comparisons with corrosion casting and 2-dimensional and 3-dimensional scanning electron microscopy. The comparisons demo…
Validation of lung densitometry threshold at CT for the distinction between senile lung and emphysema in elderly subjects
2015
Background and Aims. An ageing lung is characterised by distal airspace enlargement without alveolar wall destruction: therefore the anatomical distinction between senile lung and emphysema is clear-cut. In clinical settings the definition of precise boundaries between normalcy and pathology is more difficult with the risk of overdiagnosis. CT is an important diagnostic advancement in the field of COPD. Most methods for the evaluation of emphysema are based on the detection and measurement of areas characterised by a density level below a threshold assumed to characterize parenchymal destruction. Methods. Our retrospective study included 47 healthy subjects (65-91 years), 36 never smokers a…
Comparative intention-to-treat analysis of the video-assisted thoracoscopic surgery approach to pulmonary segmentectomy for lung carcinoma
2015
Objectives To compare the video-assisted thoracoscopic surgery (VATS) with the open thoracotomy access to pulmonary segmentectomy by the clinical outcomes and long-term survival in lung carcinoma. Methods Non-randomized comparative intention-to-treat study of prospective institutional registry data and survival data of 100 consecutive patients undergoing segmentectomy. Results Within one decade (2002-12), 100 patients with proven or highly suspected lung carcinoma underwent 100 anatomical sub-lobar pulmonary resections (52 typical and 20 atypical segmentectomies, 28 split-lobe procedures). Fifty-six patients were operated by VATS and 44 by thoracotomy access. Comparison of demographic, medi…
Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…
2008
Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…
Cognitive estimation: Performance of patients with focal frontal and posterior lesions
2018
The Cognitive Estimation Test (CET) is a widely used test to investigate estimation abilities requiring complex processes such as reasoning, the development and application of appropriate strategies, response plausibility checking as well as general knowledge and numeracy (e.g., Shallice and Evans, 1978; MacPherson et al., 2014). Thus far, it remains unknown whether the CET is both sensitive and specific to frontal lobe dysfunction. Neuroimaging techniques may not represent a useful methodology for answering this question since the complex processes involved are likely to be associated with a large network of brain regions, some of which are not functionally necessary to successfully carry …
Spectrum of collateral findings in multislice CT coronary angiography.
2007
Purpose. The aim of the study was to investigate the prevalence of the noncardiac collateral findings during multislice computed tomography coronary angiography (MSCT-CA). Materials and methods. Six hundred and seventy patients undergoing MSCT-CA with 16-slice and 64-slice CT scanners for suspected atherosclerotic disease of the coronary arteries were retrospectively reviewed. All data sets obtained with a large field of view (FOV) were analysed by two radiologists using standard mediastinal and lung window settings. Collateral findings were divided according to clinical importance into nonsignificant, remarkable and compulsory to be investigated. Results. Eighty-five percent of patients re…
The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation
2021
BACKGROUND: The use of computer navigation has been shown to produce more accurate cup positioning when compared with non-navigated total hip arthroplasty (THA), but so far there is only limited evidence to show its effect on clinical outcomes. The present study analyzed data from the Australian Orthopaedic Association National Joint Replacement Registry to assess the impact of computer navigation on the rates of all-cause revision and revision for dislocation following THA. METHODS: Data for all non-navigated and navigated primary THAs performed for osteoarthritis in Australia from January 1, 2009, to December 31, 2019, were examined to assess the rate of revision. We analyzed the effects …
Revision Rate of Misplaced Pedicle Screws of the Thoracolumbar Spine-Comparison of Three-Dimensional Fluoroscopy Navigation with Freehand Placement: …
2017
BACKGROUND Recent studies have shown higher accuracy rates of image-guided pedicle screw placement compared to freehand (FH) placement. However, data focusing on the impact of spinal navigation on the rate of revision surgeries caused by misplaced pedicle screws (PS) are scarce. OBJECTIVE This study is aimed at identifying the rate of revision surgeries for misplaced PS comparing three-dimensional (3D) fluoroscopy navigation (3DFL) with FH PS placement. METHODS A retrospective analysis was conducted of 2232 patients (mean age, 65.3 ± 13.5 years) with 13,703 implanted PS who underwent instrumentation of the thoracolumbar spine between 2007 and 2015. Group 1 received surgery with use of 3DFL …